The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Trabecular bone exhibits fully linear elastic behavior and yields at low strains
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Self-citationThe mechanics of three-dimensional cellular materials
Gibson, I. J., & Ashby, M. F. (1982) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1982.0088 · Cited by 1,885
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
The mechanical behaviour of cancellous bone
Gibson, L. J. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90287-8 · Cited by 932
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Limitations of the continuum assumption in cancellous bone
Harrigan, T. P., Jasty, M., Mann, R. W., & Harris, W. H. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90257-6 · Cited by 305
Mechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199001000-00020 · Cited by 284
Self-citationTensile and compressive properties of cancellous bone
Røhl, L., Larsen, E., Linde, F., Odgaard, A., & Jørgensen, J. (1991) · Journal of Biomechanics · doi:10.1016/0021-9290(91)90006-9 · Cited by 279
The effect of specimen geometry on the mechanical behaviour of trabecular bone specimens
Linde, F., Hvid, I., & Madsen, F. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90255-y · Cited by 233
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Self-citationDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Self-citationSystematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Self-citationKeaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationLiu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., & Guo, X. E. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060716 · Cited by 207
Self-citation
Metadata
- Authors
- Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1994-09
- Volume
- 27
- Issue
- 9
- Pages
- 1127-1136
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2124283903
- Cited by
- 300
- References
- 34
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trabecular bone exhibits fully linear elastic behavior and yields at low strains. https://app.cochat.ai/papers/10.1016/0021-9290(94)90053-1
- The paper
- Keaveny, T. M., Guo, X. E., Wachtel, E. F., McMahon, T. A., & Hayes, W. C. (1994). Trabecular bone exhibits fully linear elastic behavior and yields at low strains. Journal of Biomechanics. https://doi.org/10.1016/0021-9290(94)90053-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.