The DOI matches its Crossref record.
Mechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study
Abstract
We have investigated the relationships between trabecular bone compressive strength and elastic modulus and the directly measured apparent density and noninvasively measured CT equivalent mineral density for 49 cylindrical specimens harvested from fresh human proximal femora. Compressive strength demonstrated a high positive correlation with both densities, being proportional to the apparent density raised to the 1.8 power (R2 = 0.93) and equivalent mineral density to the 1.5 power (R2 = 0.89). Similarly, the compressive modulus demonstrated a high correlation with both density measures, being proportional to the apparent density raised to the 1.4 power (R2 = 0.91) and CT equivalent mineral density to the 1.2 power (R2 = 0.90). Though variations in architecture and bone marrow fat were observed to influence trabecular properties, the data presented here demonstrate that apparent density, compressive strength, and elastic modulus can be determined accurately using single energy quantitative CT. We expect that the use of these noninvasive data will result in improved estimates of that component of hip fracture risk that is attributable to bone strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone tissue engineering using polycaprolactone scaffolds fabricated via selective laser sintering
Williams, J. M., Adewunmi, A., Schek, R. M., Flanagan, C. L., Krebsbach, P. H., Feinberg, S. E., Hollister, S. J., & Das, S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.057 · Cited by 1,563
Bobbert, F. S. L., Lietaert, K., Eftekhari, A. A., Pouran, B., Ahmadi, S. M., Weinans, H., & Zadpoor, A. A. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.02.024 · Cited by 873
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Simple measurement of femoral geometry predicts hip fracture: The study of osteoporotic fractures
Faulkner, K. G., Cummings, S. R., Black, D., Palermo, L., Glüer, C.-C., & Genant, H. K. (1993) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650081008 · Cited by 706
Metadata
- Authors
- Lotz, J. C., Gerhart, T. N., & Hayes, W. C.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1990-01
- Volume
- 14
- Issue
- 1
- Pages
- 107-114
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1972117966
- Cited by
- 284
- References
- 0
- FWCI
- 6.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study. https://app.cochat.ai/papers/10.1097/00004728-199001000-00020
- The paper
- Lotz, J. C., Gerhart, T. N., & Hayes, W. C. (1990). Mechanical Properties of Trabecular Bone from the Proximal Femur: A Quantitative CT Study. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199001000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.