Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record.

A theoretical solution for the frictionless rolling contact of cylindrical biphasic articular cartilage layers

Open access
Ateshian, Gerard A., Wang, Huiqun · 1995 · Journal of Biomechanics

Abstract

Previous studies have shown that interstitial fluid pressurization plays an important role in the load support mechanism of articular cartilage under normal step loading. These studies have demonstrated that interstitial fluid pressurization decreases with time if the applied load is maintained constant. In the present study, a theoretical solution is obtained for another common loading of articular cartilage, namely the contact of surfaces in rolling motion. Pure rolling of symmetrical frictionless cylindrical cartilage layers is analyzed under steady state. The linear biphasic model of Mow et al. [J. Biomech. Engng 102, 73-84 (1980)] is used to describe the mechanical response of articular cartilage. The solution of this contact problem reduces to simultaneously solving a set of four integral equations, akin to the dual integral problem of elastic contact. It is found that the solution is dependent on four non-dimensional parameters: Rh = Vb/HAk, W/2 mu b, R/b, and v, where V is the surface velocity, b the cartilage thickness, HA the aggregate modulus, mu the shear modulus, v Poisson's ratio, k the permeability, R the radius of cylindrical surfaces, and W the applied load per unit cylinder length. For Rh << 1, interstitial fluid pressurization is found to be negligible, and all the applied load is supported by the solid collagen-proteoglycan phase of the tissue, thus causing significant cartilage deformation. As Rh increases to a physiological level (Rh approximately 10(4)), interstitial fluid pressurization may support more than 90% of the total applied load, shielding the solid matrix from high effective stresses and reducing matrix strains and deformation. The protective effect of interstitial fluid pressurization is observed to increase with increasing joint congruence (R/b); similarly, as the applied load (W/2 mu b) is increased, a greater proportion of it is supported by the fluid. In degenerative cartilage, Rh may drop by one or more orders of magnitude, primarily as a result of increased permeability. Thus, the protective stress-shielding effect of interstitial fluid pressurization may become less effective in diseased tissue, possibly setting a pathway for further tissue degeneration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0021-9290(95)00008-6

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Ateshian, G. A., & Wang, H.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
1995-11
Volume
28
Issue
11
Pages
1341-1355
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2089171345
Cited by
206
References
0
FWCI
4.57
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A theoretical solution for the frictionless rolling contact of cylindrical biphasic articular cartilage layers. https://app.cochat.ai/papers/10.1016/0021-9290(95)00008-6
The paper
Ateshian, G. A., & Wang, H. (1995). A theoretical solution for the frictionless rolling contact of cylindrical biphasic articular cartilage layers. Journal of Biomechanics. https://doi.org/10.1016/0021-9290(95)00008-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.