Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record.

The biomechanics of the human patella during passive knee flexion

Open access
Heegaard, J., Leyvraz, P.F., Curnier, A., Rakotomanana, L., Huiskes, R. · 1995 · Journal of Biomechanics

Abstract

The fundamental objectives of patello-femoral joint biomechanics include the determination of its kinematics and of its dynamics, as a function of given control parameters like knee flexion or applied muscle forces. On the one hand, patellar tracking provides quantitative information about the joint's stability under given loading conditions, whereas patellar force analyses can typically indicate pathological stress distributions associated for instance with abnormal tracking. The determination of this information becomes especially relevant when facing the problem of evaluating surgical procedures in terms of standard (i.e. non-pathological) knee functionality. Classical examples of such procedures include total knee replacement (TKR) and elevation of the tibial tubercle (Maquet's procedure). Following this perspective, the current study was oriented toward an accurate and reliable determination of the human patella biomechanics during passive knee flexion. To this end, a comprehensive three-dimensional computer model, based on the finite element method, was developed for analyzing articular biomechanics. Unlike previously published studies on patello-femoral biomechanics, this model simultaneously computed the joint's kinematics, associated tendinous and ligamentous forces, articular contact pressures and stresses occurring in the joint during its motion. The components constituting the joint (i.e. bone, cartilage, tendons) were modeled using objective forms of non-linear elastic materials laws. A unilateral contact law allowing for large slip between the patella and the femur was implemented using an augmented Lagrangian formulation. Patellar kinematics computed for two knee specimens were close to equivalent experimental ones (average deviations below 0.5 degrees for the rotations and below 0.5 mm for the translations) and provided validation of the model on a specimen by specimen basis. The ratio between the quadriceps pulling force and the patellar tendon force was less than unity throughout the considered knee flexion range (30-150 degrees), with a minimum near 90 degrees of flexion for both specimens. The contact patterns evolved from the distal part of the retropatellar articular surface to the proximal pole during progressive flexion. The lateral facet bore more pressure than the medial one, with corresponding higher stresses (hydrostatic) in the lateral compartment of the patella. The forces acting on the patella were part of the problem unknowns, thus leading to more realistic loadings for the stress analysis, which was especially important when considering the wide range of variations of the contact pressure acting on the patella during knee flexion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0021-9290(95)00059-q

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 180

Metadata

Authors
Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
1995-11
Volume
28
Issue
11
Pages
1265-1279
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2166361133
Cited by
180
References
0
FWCI
5.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The biomechanics of the human patella during passive knee flexion. https://app.cochat.ai/papers/10.1016/0021-9290(95)00059-q
The paper
Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R. (1995). The biomechanics of the human patella during passive knee flexion. Journal of Biomechanics. https://doi.org/10.1016/0021-9290(95)00059-q

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.