The biomechanics of the human patella during passive knee flexion
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
The fundamental objectives of patello-femoral joint biomechanics include the determination of its kinematics and of its dynamics, as a function of given control parameters like knee flexion or applied muscle forces. On the one hand, patellar tracking provides quantitative information about the joint's stability under given loading conditions, whereas patellar force analyses can typically indicate pathological stress distributions associated for instance with abnormal tracking. The determination of this information becomes especially relevant when facing the problem of evaluating surgical procedures in terms of standard (i.e. non-pathological) knee functionality. Classical examples of such procedures include total knee replacement (TKR) and elevation of the tibial tubercle (Maquet's procedure). Following this perspective, the current study was oriented toward an accurate and reliable determination of the human patella biomechanics during passive knee flexion. To this end, a comprehensive three-dimensional computer model, based on the finite element method, was developed for analyzing articular biomechanics. Unlike previously published studies on patello-femoral biomechanics, this model simultaneously computed the joint's kinematics, associated tendinous and ligamentous forces, articular contact pressures and stresses occurring in the joint during its motion. The components constituting the joint (i.e. bone, cartilage, tendons) were modeled using objective forms of non-linear elastic materials laws. A unilateral contact law allowing for large slip between the patella and the femur was implemented using an augmented Lagrangian formulation. Patellar kinematics computed for two knee specimens were close to equivalent experimental ones (average deviations below 0.5 degrees for the rotations and below 0.5 mm for the translations) and provided validation of the model on a specimen by specimen basis. The ratio between the quadriceps pulling force and the patellar tendon force was less than unity throughout the considered knee flexion range (30-150 degrees), with a minimum near 90 degrees of flexion for both specimens. The contact patterns evolved from the distal part of the retropatellar articular surface to the proximal pole during progressive flexion. The lateral facet bore more pressure than the medial one, with corresponding higher stresses (hydrostatic) in the lateral compartment of the patella. The forces acting on the patella were part of the problem unknowns, thus leading to more realistic loadings for the stress analysis, which was especially important when considering the wide range of variations of the contact pressure acting on the patella during knee flexion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“PFPS can be diagnosed and treated more effectively if normal patellar tracking is known.”
From Patellar Tracking during the Gait Cycle (2011) · cites this paper as [5]
Citations
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,802
An Introduction to Continuum Mechanics
Gurtin, M. E., & Drugan, W. J. (1984) · Journal of Applied Mechanics · doi:10.1115/1.3167763 · Cited by 1,704
An Introduction to Continuum Mechanics
(1981) · Mathematics in Science and Engineering/Mathematics in science and engineering · doi:10.1016/s0076-5392(08)x6102-8 · Cited by 1,508
A first course in rational continuum mechanics
Truesdell, C. A. (1976) · Cited by 1,031
Patellofemoral contact pressures. The influence of q-angle and tendofemoral contact.
Huberti, H. H., & Hayes, W. C. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466050-00010 · Cited by 840
A mixed formulation for frictional contact problems prone to Newton like solution methods
Alart, P., & Curnier, A. (1991) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(91)90022-x · Cited by 758
Self-citationRoentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.
Selvik, G. (1989) · PubMed · Cited by 702
Basic orthopaedic biomechanics
Mow, V. C., & Hayes, W. C. (1991) · Medical Entomology and Zoology · Cited by 655
A finite element method for a class of contact-impact problems
Hughes, T. J. R., Taylor, R. L., III, Sackman, J. L., Curnier, A., & Kanok‐Nukulchai, W. (1976) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(76)90018-9 · Cited by 597
Self-citationA survey of finite element analysis in orthopedic biomechanics: The first decade
Huiskes, R., & Chao, E. Y. S. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90072-6 · Cited by 539 · cited 1×
“A general description of this method, its principles, its possibilities and limitations in orthopedic biomechanics has been published by Huiskes and Chao (1983).”
MethodSelf-citation
Research works printed but not linked: 4
- Bandi, 1970, Chondromallacia Patellae und Femoro-Patellare Arthrose, Helv. Chir. Acta, 11, 1
- Muller, 1980, Etude photoelasticimétrique tridimensionnelle de la patella (rotule). Méthodologie et premiers résultats, Bull. Assoc. Anat., 89
- Shoji, 1974, A study of the patello-femoral contact zones in human knees, J. Jap. orthop. Ass., 48, 85
- Truesdell, 1977, Vol. 1
Cited by
Peña, E., Calvo, B., Martínez, M. A., & Doblaré, M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.04.030 · Cited by 506
Eckstein, F., Cicuttini, F., Raynauld, J.-P., Waterton, J. C., & Peterfy, C. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2006.02.026 · Cited by 418
Bony and cartilaginous anatomy of the patellofemoral joint
Tecklenburg, K., Dejour, D. H., Hoser, C., & Fink, C. (2005) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-005-0683-0 · Cited by 305
Peña, E., Calvo, B., Martínez, M. A., Palanca, D., & Doblaré, M. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.01.009 · Cited by 285
Gardiner, J. C., & Weiss, J. A. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00113-x · Cited by 238
“The use of computational methods for the study of joint mechanics can elucidate ligament function and yield information that is difficult or impossible to obtain experimentally [2] [3] [9] [16] [17].”
BackgroundVanwanseele, B., Lucchinetti, E., & Stüssi, E. (2002) · Osteoarthritis and Cartilage · doi:10.1053/joca.2002.0529 · Cited by 234
Biomechanics of the knee joint in flexion under various quadriceps forces
Mesfar, W., & Shirazi-Adl, A. (2005) · The Knee · doi:10.1016/j.knee.2005.03.004 · Cited by 233
“The extensor mechanism or quadriceps muscle group has often been represented by a single muscle (rectus femoris, RF) [17,21,23–29].”
BackgroundInfluentialAmeye, L. G., & Chee, W. S. (2006) · Arthritis Research & Therapy · doi:10.1186/ar2016 · Cited by 225
Gupta, H. S., Schratter, S., Tesch, W., Roschger, P., Berzlanovich, A., Schoeberl, T., Klaushofer, K., & Fratzl, P. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2004.10.010 · Cited by 224
“The bone–cartilage interface in articulating joints is designed to resist static and dynamic loading generated in vivo, which are accompanied by high stresses and strains (Ahmed et al., 1987; Heegard et al., 1995; Wong and Carter, 2003).”
BackgroundThe role of the medial ligamentous structures on patellar tracking during knee flexion
Philippot, R., Boyer, B., Testa, R., Farizon, F., & Moyen, B. (2011) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-011-1598-6 · Cited by 223
Stammberger, T., Eckstein, F., Englmeier, K., & Reiser, M. F. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199903)41:3<529::aid-mrm15>3.0.co;2-z · Cited by 205
The Basic Science of the Patella: Structure, Composition, and Function
Fox, A. J. S., Wanivenhaus, F., & Rodeo, S. A. (2012) · The Journal of Knee Surgery · doi:10.1055/s-0032-1313741 · Cited by 193
Eckstein, F., Gavazzeni, A., Sittek, H., Haubner, M., Lösch, A., Milz, S., Englmeier, K., Schulte, E. K. W., Putz, R. V., & Reiser, M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360213 · Cited by 191
Eckstein, F., Westhoff, J. H., Sittek, H., Maag, K.-P., Haubner, M., Faber, S., Englmeier, K., & Reiser, M. (1998) · American Journal of Roentgenology · doi:10.2214/ajr.170.3.9490936 · Cited by 191
Articular Cartilage Contact Pressure after Tibial Tuberosity Transfer: A Cadaveric Study
Kuroda, R., Kambic, H., Valdevit, A., & Andrish, J. T. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290040301 · Cited by 180
“structures, which are also important factors for patellar stability.(16) Both the magnitude of tibial tuberosity dis-”
BackgroundResultA Modeling Framework to Estimate Patellofemoral Joint Cartilage Stress In Vivo
Besier, T. F., Gold, G. E., Beaupré, G. S., & Delp, S. L. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000176686.18683.64 · Cited by 167
“Although the finite element component of the model may be considered “simple” compared with previous models (18,22), our approach is well suited to understand stress distributions throughout articular cartilage across a wide range of subjects performing different tasks under physiologic loading conditions.”
BackgroundResultA new method to investigate in vivo knee behavior using a finite element model of the lower limb
Beillas, P., Papaioannou, G., Tashman, S., & Yang, K. H. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00435-4 · Cited by 162
Three-dimensional finite element modeling of ligaments: Technical aspects
Weiss, J. A., Gardiner, J. C., Ellis, B. J., Lujan, T. J., & Phatak, N. S. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.05.006 · Cited by 161
Contact Pressure at Osteochondral Donor Sites in the Patellofemoral Joint
Garretson, R. B., Katolik, L. I., Verma, N. N., Beck, P. R., Bach, B. R., & Cole, B. J. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261706 · Cited by 161
Recent Advances in Computational Mechanics of the Human Knee Joint
Kazemi, M., Dabiri, Y., & Li, L. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/718423 · Cited by 156
The distribution of cartilage thickness within the joints of the lower limb of elderly individuals
ADAM, C., Eckstein, F., Milz, S., & Putz, R. V. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19320203.x · Cited by 153
Krishnan, R., Park, S., Eckstein, F., & Ateshian, G. A. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1610018 · Cited by 147
Eckstein, F., Adam, C., Sittek, H., Becker, C., Milz, S., Schulte, E. K. W., Reiser, M. F., & Putz, R. V. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)81146-3 · Cited by 144
Measuring Cartilage Morphology with Quantitative Magnetic Resonance Imaging
Eckstein, F., & Gläser, C. (2004) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-2004-861579 · Cited by 142
The cartilaginous and osseous geometry of the femoral trochlear groove
Shih, Y., Bull, A. M. J., & Amis, A. A. (2003) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-003-0414-3 · Cited by 141
Evaluation of a computational model used to predict the patellofemoral contact pressure distribution
Elias, J. J., Wilson, D. R., Adamson, R., & Cosgarea, A. J. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00306-3 · Cited by 137
Physical validation of a patient-specific contact finite element model of the ankle
Anderson, D. D., Goldsworthy, J. K., Li, W., Rudert, M., Tochigi, Y., & Brown, T. D. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.01.024 · Cited by 136
Gelbke, M. K., Coombs, D. J., Powell, S., & DiPasquale, T. G. (2010) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e3181f6c001 · Cited by 134
A Three-Dimensional Musculoskeletal Model of the Human Knee Joint. Part 1: Theoretical Construction
Pandy, M. G., SASAKI, K., & KIM, S. (1997) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/01495739708936697 · Cited by 131
Campbell, C. A., Horstman, C. L., Mason, D. R., & Evans, R. B. (2010) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.236.8.887 · Cited by 128
Henderson, I. J. P., & Lavigne, P. (2006) · The Knee · doi:10.1016/j.knee.2006.04.006 · Cited by 118
Tibial axis and patellar position relative to the femoral epicondylar axis during squatting
Coughlin, K. M., Incavo, S. J., Churchill, D. L., & Beynnon, B. D. (2003) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(03)00449-2 · Cited by 113
In Vivo Tracking of the Human Patella Using Cine Phase Contrast Magnetic Resonance Imaging
Sheehan, F. T., Zajac, F. E., & DRACE, J. E. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2800868 · Cited by 108
Baldwin, M. A., Clary, C. W., Maletsky, L. P., & Rullkoetter, P. J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.06.028 · Cited by 108
Fernandez, J., & Hunter, P. J. (2005) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-005-0072-0 · Cited by 108
MAGNETIC RESONANCE IMAGING OF PATELLOFEMORAL KINEMATICS WITH WEIGHT-BEARING
Patel, V. V., HALL, K., Ries, M. D., Lindsey, C. T., Ozhinsky, E., Lü, Y., & Majumdar, S. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200312000-00021 · Cited by 102
Graichen, H., Springer, V., Flaman, T., Stammberger, T., Gläser, C., Englmeier, K., Reiser, M. F., & Eckstein, F. (2000) · Osteoarthritis and Cartilage · doi:10.1053/joca.1999.0278 · Cited by 101
Stäubli, H.-U., Bollmann, C., Kreutz, R., Becker, W., & Rauschning, W. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.3.10470905 · Cited by 94
Ali, A. A., Shalhoub, S. S., Cyr, A. J., Fitzpatrick, C. K., Maletsky, L. P., Rullkoetter, P. J., & Shelburne, K. B. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.12.020 · Cited by 93
Adam, C., Eckstein, F., Milz, S., Schulte, E. K. W., Becker, C., & Putz, R. V. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)85881-0 · Cited by 92
Heegaard, J. H., Leyvraz, P., & Hovey, C. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00020-1 · Cited by 87
Self-citationCaruntu, D. I., & Hefzy, M. S. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1644565 · Cited by 85
Lösch, A., Eckstein, F., Haubner, M., & Englmeier, K. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00012-x · Cited by 84
A Mathematical Formulation for 3D Quasi-Static Multibody Models of Diarthrodial Joints
Kwak, S. D., Blankevoort, L., & Ateshian, G. A. (2000) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840008915253 · Cited by 79
Biomechanics of the knee extensor mechanism and its relationship to patella tendinopathy: A review
Dan, M. J., Parr, W. C., Broe, D., Cross, M. J., & Walsh, W. R. (2018) · Journal of Orthopaedic Research® · doi:10.1002/jor.24120 · Cited by 75
Revision Total Knee Arthroplasty for Component Malrotation is Highly Beneficial
Lakstein, D., Zarrabian, M., Kosashvili, Y., Safir, O. A., Gross, A. E., & Backstein, D. J. (2010) · The Journal of Arthroplasty · doi:10.1016/j.arth.2009.07.004 · Cited by 75
Elias, J. J., Cech, J. A., Weinstein, D. M., & Cosgrea, A. J. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262167 · Cited by 72
An X‐FEM approach for large sliding contact along discontinuities
Nistor, I., Guiton, M., Massin, P., Moës, N., & Géniaut, S. (2008) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.2532 · Cited by 72
Evolution of the patellar sesamoid bone in mammals
Samuels, M. E., Regnault, S., & Hutchinson, J. R. (2017) · PeerJ · doi:10.7717/peerj.3103 · Cited by 68
Patellar tracking during total knee arthroplasty: an in vitro feasibility study
Belvedere, C., Catani, F., Ensini, A., de la Barrera, J. L. M., & Leardini, A. (2007) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-007-0320-1 · Cited by 68
Peña, E., del Palomar, A. P., Calvo, B., Martínez, M. Á., & Doblaré, M. (2007) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-006-9001-3 · Cited by 64
Biomechanics of knee joint — A review
Madeti, B. K., Chalamalasetti, S. R., & Bollapragada, S. K. S. S. R. (2015) · Frontiers of Mechanical Engineering · doi:10.1007/s11465-014-0306-x · Cited by 64
In vivo contact areas of the knee in patients with patellar subluxation
Hinterwimmer, S., Gotthardt, M., von Eisenhart‐Rothe, R., Sauerland, S., Siebert, M., Vogl, T. J., Eckstein, F., & Graichen, H. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.008 · Cited by 62
Pappas, G. P., Vogelsong, M. A., Staroswiecki, E., Gold, G. E., & Safran, M. R. (2016) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0000000000000283 · Cited by 61
Study of patellar kinematics after reconstruction of the medial patellofemoral ligament
Philippot, R., Boyer, B., Testa, R., Farizon, F., & Moyen, B. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2011.08.001 · Cited by 61
Three-Dimensional Finite Element Simulation of Total Knee Joint in Gait Cycle
Guo, Y., Zhang, X., & Chen, W. (2009) · Acta Mechanica Solida Sinica · doi:10.1016/s0894-9166(09)60283-4 · Cited by 58
The effects of trochlear groove geometry on patellofemoral joint stability-a computer model study
Jafari, A., Farahmand, F., & Meghdari, A. F. (2008) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/09544119jeim255 · Cited by 58
Ling, M., Zhan, S., Jiang, D., Hu, H. X., & Zhang, C. (2019) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-019-1060-x · Cited by 58
Stammberger, T., Hohe, J., Englmeier, K., Reiser, M. F., & Eckstein, F. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<592::aid-mrm13>3.0.co;2-j · Cited by 58
Alterations in the Patella After a High Tibial or Distal Femoral Osteotomy
Closkey, R. F., & Windsor, R. E. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200108000-00009 · Cited by 57
Influence of the contact model on the dynamic response of the human knee joint
Machado, M., Flores, P., Ambrósio, J., & Completo, A. (2011) · Proceedings of the Institution of Mechanical Engineers Part K Journal of Multi-body Dynamics · doi:10.1177/1464419311413988 · Cited by 56
Patellar Tracking and Patellofemoral Geometry in Deep Knee Flexion
Moro‐oka, T., Matsuda, S., Miura, H., Nagamine, R., Urabe, K., Kawano, T., HIGAKI, H., & Iwamoto, Y. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200201000-00019 · Cited by 54
Biomechanical background and clinical observations of rotational malalignment in TKA:
Zihlmann, M. S., Stacoff, A., Romero, J., Quervain, I. A. K., & Stüssi, E. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.03.014 · Cited by 53
Liska, F., von Deimling, C., Otto, A., Willinger, L., Kellner, R., Imhoff, A. B., Burgkart, R., & Voß, A. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-5165-2 · Cited by 53
In vivo patellar tracking and patellofemoral cartilage contacts during dynamic stair ascending
Suzuki, T., Hosseini, A., Li, J., Gill, T. J., & Li, G. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.06.034 · Cited by 51
Computer simulation of damage on distal femoral articular cartilage after meniscectomies
Peña, E., Calvo, B., Martínez, M. Á., & Doblaré, M. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.07.003 · Cited by 50
Active Patellar Tracking Measurement: A Novel Device Using Ultrasound
Shih, Y., Bull, A. M. J., McGregor, A. H., & Amis, A. A. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262693 · Cited by 50
Eckstein, F., Milz, S., Anetzberger, H., & Putz, R. V. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19210081.x · Cited by 50
Fernandez, J., Akbarshahi, M., Kim, H. J., & Pandy, M. G. (2007) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840701551046 · Cited by 48
Skwara, A., Tibesku, C. O., Ostermeier, S., Stukenborg-Colsman, C. M., & Fuchs‐Winkelmann, S. (2008) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-008-0757-9 · Cited by 48
New Methods for Assessing Cartilage Contact Stress after Articular Fracture
Brown, T. D., Rudert, M., & Grosland, N. M. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000132633.38338.8b · Cited by 47
In vivo movement analysis of the patella using a three-dimensional computer model
YAMADA, Y., Toritsuka, Y., Horibe, S., Sugamoto, K., Yoshikawa, H., & Shino, K. (2007) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.89b6.18515 · Cited by 45
A New Kinematic Model of the Passive Motion of the Knee Inclusive of the Patella
Sancisi, N., & Parenti‐Castelli, V. (2011) · Journal of Mechanisms and Robotics · doi:10.1115/1.4004890 · Cited by 45
Toward patient-specific articular contact mechanics
Ateshian, G. A., Henak, C. R., & Weiss, J. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.020 · Cited by 42
Quantitative MR measures of three-dimensional patellar kinematics as a research and diagnostic tool
Sheehan, F. T., & DRACE, J. E. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199910000-00007 · Cited by 41
Displacements of the Tibial Tuberosity; Effects of the Surgical Parameters
Benvenuti, J.-F., Rakotomanana, L. R., Leyvraz, P., Pioletti, D. P., Heegaard, J. H., & Genton, M. G. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199710000-00033 · Cited by 41
Self-citationHirschmann, A. C., Buck, F. M., Herschel, R., Pfirrmann, C. W. A., & Fucentese, S. F. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3853-8 · Cited by 39
Keshmiri, A., Maderbacher, G., Baier, C., Zeman, F., Grifka, J. K., & Springorum, H.-R. (2014) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-014-3434-2 · Cited by 39
Elias, J. J., Kilambi, S., & Cosgarea, A. J. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.10.039 · Cited by 38
ROLE OF PERIPATELLAR RETINACULUM IN TRANSMISSION OF FORCES WITHIN THE EXTENSOR MECHANISM
Powers, C. M., CHEN, Y.-J., Farrokhi, S., & LEE, T. Q. (2006) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200609000-00019 · Cited by 36
Correlation Between Knee Kinematics and Patellofemoral Contact Pressure in Total Knee Arthroplasty
Konno, T., Onodera, T., Nishio, Y., Kasahara, Y., Iwasaki, N., & Majima, T. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2014.07.020 · Cited by 35
Computational Modeling: An Alternative Approach for Investigating Patellofemoral Mechanics
Elias, J. J., & Cosgarea, A. J. (2007) · Sports Medicine and Arthroscopy Review · doi:10.1097/jsa.0b013e31804bbe4d · Cited by 35
Computer-aided three dimensional assessment of knee-joint cartilage with magnetic resonance imaging
Muensterer, O. J., Eckstein, F., Hahn, D. W., & Putz, R. V. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00069-0 · Cited by 35
Belvedere, C., Leardini, A., Ensini, A., Bianchi, L., Catani, F., & Giannini, S. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20919 · Cited by 33
Lee, T. Q., Sandusky, M. D., Adeli, A., & McMahon, P. J. (2002) · PubMed · Cited by 32
Biphasic Analysis of Cartilage Stresses in the Patellofemoral Joint
Jones, B., Hung, C. T., & Ateshian, G. A. (2015) · The Journal of Knee Surgery · doi:10.1055/s-0035-1568989 · Cited by 31
Human patellar articular proportions: recent and Pleistocene patterns
Trinkaus, E. (2000) · Journal of Anatomy · doi:10.1046/j.1469-7580.2000.19630473.x · Cited by 28
Morphological analysis of the knee joint in patients with hip dysplasia
Li, H., Qu, X., Wang, Y., Dai, K., & Zhu, Z. (2012) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-012-2242-9 · Cited by 28
von Engelhardt, L. V., Weskamp, P., Lahner, M., Spahn, G., & Jerosch, J. (2017) · World Journal of Orthopedics · doi:10.5312/wjo.v8.i12.935 · Cited by 28
Horng, A., Raya, J. G., Stockinger, M., Notohamiprodjo, M., Pietschmann, M. F., Hoehne-Hueckstaedt, U. M., Glitsch, U., Ellegast, R. P., Hering, K. G., & Gläser, C. (2015) · European Radiology · doi:10.1007/s00330-014-3545-7 · Cited by 27
Modeling of the condyle elements within a biomechanical knee model
Ribeiro, A., Rasmussen, J., Flores, P., & da Silva, L. F. (2011) · Multibody System Dynamics · doi:10.1007/s11044-011-9280-9 · Cited by 27
Geometric properties of 2D and 3D unilateral large slip contact operators
Heegaard, J. H., & Curnier, A. (1996) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(95)00977-9 · Cited by 27
Self-citationA clinical overview patellofemoral joint and application to total knee arthroplasty
Stiehl, J. B. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.026 · Cited by 24
Philippot, R., Chouteau, J., Testa, R., & Moyen, B. (2009) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-009-0956-0 · Cited by 23
Kim, Y. B., Kwon, M., Ryu, J. Y., & Moon, S. W. (2021) · Clinics in Orthopedic Surgery · doi:10.4055/cios20253 · Cited by 23
Effect of bracing on dynamic patellofemoral contact mechanics
Wilson, N. A., Mazahery, B., Koh, J. L., & Zhang, L.-Q. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2009.12.0204 · Cited by 23
Shah, K. S., Saranathan, A., Koya, B., & Elias, J. J. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.921814 · Cited by 22
Finite element analysis in the optimization of posterior-stabilized total knee arthroplasty
Dagneaux, L., Canovas, F., & Jourdan, F. (2023) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2023.103765 · Cited by 19
Stanescu, A. L., Ngo, A.-V. H., Parisi, M. T., Iyer, R. S., & Maloney, E. J. (2018) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-0037-1608004 · Cited by 19
MR Imaging of the Extensor Mechanism
Kramer, J., White, L. M., & Recht, M. P. (2009) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-0029-1242191 · Cited by 19
Metadata
- Authors
- Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1995-11
- Volume
- 28
- Issue
- 11
- Pages
- 1265-1279
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2166361133
- Cited by
- 180
- References
- 76
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.