Mechanics of ventricular torsion
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Recent research suggests that left ventricular torsion is an important indicator of cardiac function. We used two theoretical models to study the mechanics of this phenomenon: a compressible cylinder and an incompressible ellipsoid of revolution. The analyses of both models account for large- strain passive and active material behavior, with a muscle fiber angle that varies linearly from endocardium to epicardium. Relative to the end- diastolic configuration, the predicted torsion exhibits several experimentally observed features, including a peak near end systole, rapid untwisting during isovolumic relaxation, and increased twist near the apex. The magnitude of the twist is sensitive to the fiber architecture, the ventricular geometry, and the compressibility and contractility of the myocardium. In particular, the model predicts that the systolic twist increases with increasing compressibility, contractility, and wall thickness, while it decreases with increasing cavity volume. The peak twist approximately doubles (from about 0.02 to 0.04 rad cm(-1)) with a doubling of myocardial compressibility or with a change in the endocardial/epicardial muscle fiber angles from 90/ -90 degrees to 60/ -60 degrees. The twist is less sensitive to changes in contractility and ventricular geometry. These findings provide a basis for interpreting measurements of ventricular torsion in the clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUGA, H., SAGAWA, K., & SHOUKAS, A. A. (1973) · Circulation Research · doi:10.1161/01.res.32.3.314 · Cited by 1,502
Cardiac Contraction and the Pressure-Volume Relationship
SAGAWA, K. (1988) · Cited by 648
Gross morphology and fiber geometry of the heart
Streeter, D. D. (1979) · Medical Entomology and Zoology · Cited by 430
Buchalter, M. B., Weiss, J. L., Rogers, W. J., Zerhouni, E. A., Weisfeldt, M. L., Beyar, R., & Shapiro, E. P. (1990) · Circulation · doi:10.1161/01.cir.81.4.1236 · Cited by 360
Determination of a Constitutive Relation for Passive Myocardium: I. A New Functional Form
Humphrey, J. D., Strumpf, R. K., & Yin, F. C. P. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891193 · Cited by 352
Dissociation between left ventricular untwisting and filling. Accentuation by catecholamines.
Rademakers, F. E., Buchalter, M. B., Rogers, W. J., Zerhouni, E. A., Weisfeldt, M. L., Weiss, J. L., & Shapiro, E. P. (1992) · Circulation · doi:10.1161/01.cir.85.4.1572 · Cited by 346
A model of the mechanics of the left ventricle
Arts, T., Reneman, R. S., & Veenstra, P. C. (1979) · Annals of Biomedical Engineering · doi:10.1007/bf02364118 · Cited by 278
Determination of a Constitutive Relation for Passive Myocardium: II.—Parameter Estimation
Humphrey, J. D., Strumpf, R. K., & Yin, F. C. P. (1990) · Journal of Biomechanical Engineering · doi:10.1115/1.2891194 · Cited by 275 · cited 1×
“The myocardium again was taken as transversely isotropic, but now incompressible, with the passive strain-energy density given by (Humphrey et al., 1990)”
BackgroundIngels, N. B., Hansen, D. E., Daughters, G. T., Stinson, E. B., Alderman, E. L., & Miller, D. C. (1989) · Circulation Research · doi:10.1161/01.res.64.5.915 · Cited by 249
Guccione, J. M., Waldman, L. K., & McCulloch, A. D. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895474 · Cited by 242 · cited 1×
“Thick-walled, anisotropic, incompressible cylinder models for the active LV have been proposed by several investigators (Chadwick, 1982; Guccione et al., 1993; Nevo and Lanir, 1989; Ohayon and Chadwick, 1988; Taber, 1991b; Tozeren, 1983).”
Method
Cited by
Twist Mechanics of the Left Ventricle
Sengupta, P. P., Tajik, A. J., Chandrasekaran, K., & Khandheria, B. K. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.02.006 · Cited by 604
Left Ventricular Structure and Function
Sengupta, P. P., Korinek, J., Belohlavek, M., Narula, J., Vannan, M. A., Jahangir, A., & Khandheria, B. K. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.030 · Cited by 505
Sengupta, P. P., Krishnamoorthy, V. K., Korinek, J., Narula, J., Vannan, M. A., Lester, S. J., Tajik, J. A., Seward, J. B., Khandheria, B. K., & Belohlavek, M. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.10.013 · Cited by 323
From mechanical resilience to active material properties in biopolymer networks
Burla, F., Mulla, Y., Vos, B. E., Aufderhorst-Roberts, A., & Koenderink, G. H. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0036-4 · Cited by 224
Remodeling of cardiac fiber structure after infarction in rats quantified with diffusion tensor MRI
Chen, J., Song, S.-K., Liu, W., McLean, M., Allen, J. S., Tan, J., Wickline, S. A., & Yu, X. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00889.2002 · Cited by 207
“This structure is a key determinant of ventricular torsion, strain, and stress (2, 18, 27).”
BackgroundChen, J., Liu, W., Zhang, H., Lacy, L., Yang, X., Song, S.-K., Wickline, S. A., & Yu, X. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00041.2005 · Cited by 197
Homogeneity of Cardiac Contraction Despite Physiological Asynchrony of Depolarization: A Model Study
Kerckhoffs, R. C. P., Bovendeerd, P. H. M., Kotte, J. C. S., Prinzen, F. W., Smits, K., & Arts, T. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1566447 · Cited by 178
Notomi, Y., Srinath, G., Shiota, T., Martin-Miklovic, M. G., Beachler, L., Howell, K., Oryszak, S. J., Deserranno, D. G., Freed, A. D., Greenberg, N. L., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.537639 · Cited by 176
Jafari Tadi, M., Lehtonen, E., Saraste, A., Tuominen, J., Koskinen, J., Teräs, M., Airaksinen, J., Pänkäälä, M., & Koivisto, T. (2017) · Scientific Reports · doi:10.1038/s41598-017-07248-y · Cited by 174
Sengupta, P. P., Krishnamoorthy, V. K., Abhayaratna, W. P., Korinek, J., Belohlavek, M., Sundt, T. M., Chandrasekaran, K., Mookadam, F., Seward, J. B., Tajik, A. J., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.10.006 · Cited by 168
Age-related Changes in Left Ventricular Twist Assessed by Two-dimensional Speckle-tracking Imaging
Takeuchi, M., Nakai, H., Kokumai, M., Nishikage, T., Otani, S., & Lang, R. M. (2006) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.04.011 · Cited by 167
Effect of Fiber Geometry on Pulsatile Pumping and Energy Expenditure
Grosberg, A., Gharib, M., & Kheradvar, A. (2009) · Bulletin of Mathematical Biology · doi:10.1007/s11538-009-9414-x · Cited by 19
Cardiac torsion and electromagnetic fields: The cardiac bioinformation hypothesis
Burleson, K. O., & Schwartz, G. E. (2005) · Medical Hypotheses · doi:10.1016/j.mehy.2004.12.023 · Cited by 16
Metadata
- Authors
- Taber, L. A., Yang, M., & Podszus, W. W.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1996-06
- Volume
- 29
- Issue
- 6
- Pages
- 745-752
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2022085332
- Cited by
- 225
- References
- 26
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.