Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 275

The DOI matches its Crossref record.

Determination of a Constitutive Relation for Passive Myocardium: II.—Parameter Estimation

Humphrey, J. D., Strumpf, R. K., Yin, F. C. P.·1990·Journal of Biomechanical Engineering

Abstract

In the first paper of this series, we proposed a new transversely isotropic pseudostrain-energy function W for describing the biomechanical behavior of excised noncontracting myocardium. The specific functional form of W was inferred directly from biaxial data to be a polynomial function of two coordinate invariant measures of the finite deformation and five material parameters. In this paper, best-fit values of the material parameters are determined from biaxial data using a nonlinear least-squares regression. These values of the parameters are shown to be well-determined, and the final constitutive relation is shown to have good predictive capabilities. Since the proposed constitutive relation describes much broader classes of in-vitro biaxial data than previously proposed relations, it may be better applicable to analyses of stress in the passive heart.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2891194

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 275

Metadata

Authors
Humphrey, J. D., Strumpf, R. K., & Yin, F. C. P.
Venue
Journal of Biomechanical Engineering
Published
1990-08-01
Volume
112
Issue
3
Pages
340-346
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W2043938150
Cited by
275
References
0
FWCI
2.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of a Constitutive Relation for Passive Myocardium: II.—Parameter Estimation. https://app.cochat.ai/papers/10.1115/1.2891194
The paper
Humphrey, J. D., Strumpf, R. K., & Yin, F. C. P. (1990). Determination of a Constitutive Relation for Passive Myocardium: II.—Parameter Estimation. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2891194

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.