Estimation of the point of zero charge of simple oxides by mass titration
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
A method is proposed to estimate the point of zero charge (pzc) of pure compounds which can be described accurately by the surface ionization model of amphoteric oxides. It is demonstrated that under the limiting conditions of “infinite” mass/volume ratio, the pH of the system will approach pH∞ = 12(pK1 + pK2) pzc. Experimental values of the pH of the oxides of titanium, aluminum, a silicon suspended in a closed aqueous system exhibited the existence of a constant pH at high mass fractions. This limiting pH is found to be a reasonable estimate for the point of zero charge of each oxide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of colloid and surface chemistry
Hiemenz, P. C., & Rajagopalan, R. (1977) · Cited by 3,500
The Isoelectric Points of Solid Oxides, Solid Hydroxides, and Aqueous Hydroxo Complex Systems
Parks, G. A. (1965) · Chemical Reviews · doi:10.1021/cr60234a002 · Cited by 3,430
Principles of colloid and surface chemistry
Matijević, E. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90045-6 · Cited by 2,781
Surface ionization and complexation at the oxide/water interface
Davis, J. A., James, R. O., & Leckie, J. O. (1978) · Journal of Colloid and Interface Science · doi:10.1016/s0021-9797(78)80009-5 · Cited by 1,554
Site-binding model of the electrical double layer at the oxide/water interface
Yates, D. E., Levine, S., & Healy, T. W. (1974) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19747001807 · Cited by 1,337
Davis, J. A., & Leckie, J. O. (1978) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(78)90217-5 · Cited by 971
Structure of metallic catalysts
Boudart, M. (1978) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(78)90353-3 · Cited by 953
THE ZERO POINT OF CHARGE OF OXIDES1
Parks, G. A., & Bruyn, P. L. D. (1962) · The Journal of Physical Chemistry · doi:10.1021/j100812a002 · Cited by 803
A comparison of electrostatic models for the oxide/solution interface
Westall, J., & Hohl, H. (1980) · Advances in Colloid and Interface Science · doi:10.1016/0001-8686(80)80012-1 · Cited by 774
Adsorption from solution at the solid/liquid interface
Vincent, B. (1984) · Colloids and Surfaces · doi:10.1016/0166-6622(84)80299-1 · Cited by 591
Cited by
Patel, M., Kumar, R., Kishor, K., Mlsna, T., Pittman, C. U., & Mohan, D. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00299 · Cited by 2,654
Toward the rational design of non-precious transition metal oxides for oxygen electrocatalysis
Hong, W. T., Risch, M., Stoerzinger, K. A., Grimaud, A., Suntivich, J., & Shao-Horn, Y. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03869j · Cited by 2,089
A review on surface modification of activated carbon for carbon dioxide adsorption
Shafeeyan, M. S., Daud, W. M. A. W., Houshmand, A., & Shamiri, A. (2010) · Journal of Analytical and Applied Pyrolysis · doi:10.1016/j.jaap.2010.07.006 · Cited by 1,128
González-García, P. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.117 · Cited by 969
Sorption of pollutants by porous carbon, carbon nanotubes and fullerene- An overview
Gupta, V. K., & Saleh, T. A. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-1524-1 · Cited by 954
Liu, Q.-S., Zheng, T., Wang, P., Jiang, J.-P., & Li, N. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2009.11.013 · Cited by 911
Li, L., Quinlivan, P. A., & Knappe, D. R. U. (2002) · Carbon · doi:10.1016/s0008-6223(02)00069-6 · Cited by 758
Mouni, L., Belkhiri, L., Bollinger, J.-C., Bouzaza, A., Assadi, A., Tirri, A., Dahmoune, F., Madani, K., & Remini, H. (2018) · Applied Clay Science · doi:10.1016/j.clay.2017.11.034 · Cited by 712
Al-Ghouti, M. A., Khraisheh, M. A. M., Allen, S. J., & Ahmad, M. N. (2003) · Journal of Environmental Management · doi:10.1016/j.jenvman.2003.09.005 · Cited by 705
Effect of carbon surface chemistry on the removal of reactive dyes from textile effluent
Al-Degs, Y. (2000) · Water Research · doi:10.1016/s0043-1354(99)00200-6 · Cited by 639
Bedin, K. C., Martins, A. C., Cazetta, A. L., Pezoti, O., & Almeida, V. C. (2016) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.10.099 · Cited by 598
Removal of pharmaceutical compounds by activated carbon prepared from agricultural by-product
Baccar, R., Sarrà, M., Bouzid, J., Feki, M., & Blánquez, P. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.09.099 · Cited by 566
Electrocatalysis in Alkaline Media and Alkaline Membrane-Based Energy Technologies
Yang, Y., Peltier, C. R., Zeng, R., Schimmenti, R., Li, Q., Huang, X., Yan, Z., Potsi, G., Selhorst, R., Lu, X., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00331 · Cited by 544
Effect of HNO3 treatment on the surface acidity of activated carbons
Noh, J. S., & Schwarz, J. A. (1990) · Carbon · doi:10.1016/0008-6223(90)90069-b · Cited by 529
Self-citationEvidence for the protonation of basal plane sites on carbon
Leon y Leon, C. A., Solar, J. M., Calemma, V, & Radovic, L. R. (1992) · Carbon · doi:10.1016/0008-6223(92)90164-r · Cited by 515
CO2 capture by adsorption with nitrogen enriched carbons
Plaza, M. G., Pevida, C., Arenillas, A., Rubiera, F., & Pis, J. J. (2007) · Fuel · doi:10.1016/j.fuel.2007.06.001 · Cited by 505
Comparison of Different Methods for the Point of Zero Charge Determination of NiO
Mahmood, T., Saddique, M. T., Naeem, A., Westerhoff, P., Mustafa, S., & Alum, A. (2011) · Industrial & Engineering Chemistry Research · doi:10.1021/ie200271d · Cited by 488
Nam, S.-W., Choi, D.-J., Kim, S.-K., Her, N., & Zoh, K.-D. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.01.037 · Cited by 486
Di Paola, A., Marcì, G., Palmisano, L., Schiavello, M., Uosaki, K., Ikeda, S., & Ohtani, B. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp013074l · Cited by 480
Liu, Q.-S., Zheng, T., Wang, P., & Guo, L. (2010) · Industrial Crops and Products · doi:10.1016/j.indcrop.2009.10.011 · Cited by 476
Surface modification of activated carbons for CO2 capture
Pevida, C., Plaza, M. G., Arias, B., Fermoso, J., Rubiera, F., & Pis, J. J. (2008) · Applied Surface Science · doi:10.1016/j.apsusc.2008.05.239 · Cited by 468
The significance of the difference in the point of zero charge between rutile and anatase
Kosmulski, M. (2002) · Advances in Colloid and Interface Science · doi:10.1016/s0001-8686(02)00080-5 · Cited by 445
Choudhary, M., Kumar, R., & Neogi, S. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.122441 · Cited by 431
Bourikas, K., Kordulis, C., & Lycourghiotis, A. (2014) · Chemical Reviews · doi:10.1021/cr300230q · Cited by 418
Activated carbons for the adsorption of ibuprofen
Mestre, A. S., Pires, J., Nogueira, J. M. F., & Carvalho, A. P. (2007) · Carbon · doi:10.1016/j.carbon.2007.06.005 · Cited by 413
Gao, X., Omosebi, A., Landon, J., & Liu, K. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03172e · Cited by 412
Inguanzo, M., Domı́nguez, A., Menéndez, J. A., Blanco, C. G., & Pis, J. J. (2002) · Journal of Analytical and Applied Pyrolysis · doi:10.1016/s0165-2370(01)00155-3 · Cited by 394
Wang, S., Zhu, Z. H., Coomes, A., Haghseresht, F., & Lu, G. Q. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2004.10.050 · Cited by 393
Kumari, M., Pittman, C. U., & Mohan, D. (2015) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2014.09.012 · Cited by 377
Development of magnetic activated carbon from almond shells for trinitrophenol removal from water
Mohan, D., Sarswat, A., Singh, V. K., Alexandre-Franco, M., & Pittman, C. U. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.06.054 · Cited by 365
Menéndez, J. A., Phillips, J., Xia, B., & Radovic, L. R. (1996) · Langmuir · doi:10.1021/la9602022 · Cited by 354
Shafeeyan, M. S., Daud, W. M. A. W., Houshmand, A., & Arami-Niya, A. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2010.11.127 · Cited by 328
Preparation and characterization of activated carbon from grape stalk by zinc chloride activation
Ozdemir, I., Şahin, M., Orhan, R., & Erdem, M. (2014) · Fuel Processing Technology · doi:10.1016/j.fuproc.2014.04.002 · Cited by 325
Valorisation of spent coffee grounds as CO2 adsorbents for postcombustion capture applications
Plaza, M. G., González, A. S., Pevida, C., Pis, J. J., & Rubiera, F. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.05.028 · Cited by 313
Liu, Q.-S., Zheng, T., Li, N., Wang, P., & Abulikemu, G. (2010) · Applied Surface Science · doi:10.1016/j.apsusc.2009.12.025 · Cited by 306
Adsorption of simple aromatic compounds on activated carbons
Villacañas, F., Pereira, M. F. R., Órfão, J. J. M., & Figueiredo, J. L. (2006) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.06.032 · Cited by 301
Liu, G., Ma, J., Li, X., & Qin, Q. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.09.038 · Cited by 290
Bourikas, K., Vakros, J., Kordulis, C., & Lycourghiotis, A. (2003) · The Journal of Physical Chemistry B · doi:10.1021/jp035123v · Cited by 275
Catalytic Decomposition of Hydrogen Peroxide and 2-chlorophenol with iron oxides
Huang, H.-H., Lu, M.-C., & Chen, J.-N. (2001) · Water Research · doi:10.1016/s0043-1354(00)00496-6 · Cited by 274
Direct Measurement of Particle−Bubble Interactions in Aqueous Electrolyte: Dependence on Surfactant
Preuss, M., & Butt, H.-J. (1998) · Langmuir · doi:10.1021/la971349b · Cited by 267
Swiatkowski, A., Pakula, M., Biniak, S., & Walczyk, M. (2004) · Carbon · doi:10.1016/j.carbon.2004.06.043 · Cited by 260
Zhao, L., Sun, Z., & Ma, J. (2009) · Environmental Science & Technology · doi:10.1021/es900084w · Cited by 258
Torrellas, S. Á., García Lovera, R., Escalona, N., Sepúlveda, C., Sotelo, J. L., & García, J. (2015) · Chemical Engineering Journal · doi:10.1016/j.cej.2015.05.104 · Cited by 257
Mestre, A. S., Pires, J., Nogueira, J. M. F., Parra, J. B., Carvalho, A. P., & Ania, C. O. (2009) · Bioresource Technology · doi:10.1016/j.biortech.2008.09.039 · Cited by 257
Acidic and basic sites on the surface of porous carbon
Barton, S. S., Evans, M. J. B., Halliop, E., & MacDonald, J. A. F. (1997) · Carbon · doi:10.1016/s0008-6223(97)00080-8 · Cited by 244
Hao, Z., Wang, C., Yan, Z., Jiang, H., & Xu, H. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2018.08.038 · Cited by 235
Bifunctional Perovskite Oxide Catalysts for Oxygen Reduction and Evolution in Alkaline Media
Gupta, S., Kellogg, W., Xu, H., Liu, X., Cho, J., & Wu, G. (2016) · Chemistry – An Asian Journal · doi:10.1002/asia.201500640 · Cited by 233
Oxidation of activated carbon by dry and wet methods
Jaramillo, J., Álvarez, P. M., & Gómez-Serrano, V. (2010) · Fuel Processing Technology · doi:10.1016/j.fuproc.2010.07.018 · Cited by 228
Development of low-cost biomass-based adsorbents for postcombustion CO2 capture
Plaza, M. G., Pevida, C., Arias, B., Fermoso, J., Casal, M. D., Martín, C. F., Rubiera, F., & Pis, J. J. (2009) · Fuel · doi:10.1016/j.fuel.2009.02.025 · Cited by 216
Proton Adsorption and Electrokinetics of an Argentinean Montmorillonite
Avena, M. J., & De Pauli, C. P. (1998) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1998.5402 · Cited by 214
Developing almond shell-derived activated carbons as CO2 adsorbents
Plaza, M. G., Pevida, C., Martín, C. F., Fermoso, J., Pis, J. J., & Rubiera, F. (2010) · Separation and Purification Technology · doi:10.1016/j.seppur.2009.11.008 · Cited by 214
Gaboriaud, F., & Ehrhardt, J.-J. (2003) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(02)00988-2 · Cited by 209
“As demonstrated previously, this shift is sometime due to insuffi cient quantity of solid in the titration reactor ( Noh and Schwarz, 1989; Zalac and Kallay, 1992).”
BackgroundThe adsorption of pharmaceutically active compounds from aqueous solutions onto activated carbons
Rakić, V., Rac, V., Krmar, M., Otman, O., & Auroux, A. (2015) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.04.062 · Cited by 207
Adsorption of polycyclic aromatic hydrocarbons from water using petroleum coke-derived porous carbon
Yuan, M., Tong, S., Zhao, S., & Jia, C. Q. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.05.130 · Cited by 204
Albadarin, A. B., Al-Muhtaseb, A. H., Al-laqtah, N. A., Walker, G. M., Allen, S. J., & Ahmad, M. N. M. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.02.044 · Cited by 202
The creation of acid carbon surfaces by treatment with (NH4)2S2O8
Moreno-Castilla, C., Carrasco-Marín, F., & Mueden, A. (1997) · Carbon · doi:10.1016/s0008-6223(97)00121-8 · Cited by 200
Defluoridation of drinking water using activated titanium rich bauxite
Das, N., Pattanaik, P., & Das, R. (2005) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2005.06.045 · Cited by 196
The Role of the Liquid‐Solid Interface in the Preparation of Supported Catalysts
Bourikas, K., Kordulis, C., & Lycourghiotis, A. (2006) · Catalysis Reviews · doi:10.1080/01614940600962321 · Cited by 196
“At 1989 Noh and Schwarz developed the so called Mass Titration technique (240).”
MethodCarbon Support Surface Effects in the Gold-Catalyzed Oxidation of 5-Hydroxymethylfurfural
Donoeva, B., Masoud, N., & de Jongh, P. E. (2017) · ACS Catalysis · doi:10.1021/acscatal.7b00829 · Cited by 196
Physicochemical characteristics of a novel activated carbon produced from tea industry waste
Gundogdu, A., Duran, C., Senturk, H. B., Soylak, M., Imamoglu, M., & Onal, Y. (2013) · Journal of Analytical and Applied Pyrolysis · doi:10.1016/j.jaap.2013.07.008 · Cited by 194
Adsorption of basic dye from aqueous solution onto fly ash
Lin, J. X., Zhan, S. L., Fang, M. H., Qian, X. Q., & Yang, H. (2008) · Journal of Environmental Management · doi:10.1016/j.jenvman.2007.01.001 · Cited by 194
Removal of an analgesic using activated carbons prepared from urban and industrial residues
Cabrita, I., Ruiz, B., Mestre, A. S., Fonseca, I. M., Carvalho, A. P., & Ania, C. O. (2010) · Chemical Engineering Journal · doi:10.1016/j.cej.2010.07.058 · Cited by 193
“The pHPZC was estimated using a modification of the mass titration procedure by Noh and Schwarz [19].”
MethodPreferential removal of pesticides from water by molecular imprinting on TiO2 photocatalysts
Fiorenza, R., Di Mauro, A., Cantarella, M., Iaria, C., Scalisi, E. M., Brundo, M. V., Gulino, A., Spitaleri, L., Nicotra, G., Dattilo, S., et al. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.122309 · Cited by 193
Rizzo, L., Sannino, D., Vaiano, V., Sacco, O., Scarpa, A., & Pietrogiacomi, D. (2014) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2013.07.033 · Cited by 192
On the difference between the isoelectric point and the point of zero charge of carbons
Menéndez, J. A., Illán-Gómez, M. J., y León, C. A. L., & Radovic, L. R. (1995) · Carbon · doi:10.1016/0008-6223(95)96817-r · Cited by 189
Mestre, A. S., Bexiga, A. S., Proença, M., Andrade, M., Pinto, M. L., Matos, I., Fonseca, I. M., & Carvalho, A. P. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2011.06.024 · Cited by 177
Salem Attia, T. M., Hu, X. L., & Yin, D. Q. (2013) · Chemosphere · doi:10.1016/j.chemosphere.2013.07.046 · Cited by 176
Plaza, M. G., Pevida, C., Arias, B., Fermoso, J., Arenillas, A., Rubiera, F., & Pis, J. J. (2008) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-007-8493-x · Cited by 173
Tan, W.-F., Lu, S.-J., Liu, F., Feng, X.-H., He, J.-Z., & Koopal, L. K. (2008) · Soil Science · doi:10.1097/ss.0b013e31816d1f12 · Cited by 171
“Finally, there is a diverse group of methods that includes ion adsorption (IA) (Balistrieri and Murray, 1982), mass titration (MT) (Noh and Schwarz, 1989), scanning force microscopy (Eggleston and Jordan, 1998), and theoretical calculation of the PZC (Tripathy et al.”
BackgroundSupported Transition Metal Catalysts for Hydrodechlorination Reactions
Keane, M. A. (2011) · ChemCatChem · doi:10.1002/cctc.201000432 · Cited by 170
Diclofenac removal from water with ozone and activated carbon
Beltrán, F. J., Pocostales, P., Alvarez, P., & Oropesa, A. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.07.033 · Cited by 168
An EXAFS study of the co-ordination chemistry of hydrogen hexachloroplatinate(IV)
Spieker, W. A., Liu, J., Miller, J. T., Kropf, A. J., & Regalbuto, J. R. (2002) · Applied Catalysis A: General · doi:10.1016/s0926-860x(02)00116-3 · Cited by 160
Wang, S., & (Max)Lu, G. Q. (1998) · Carbon · doi:10.1016/s0008-6223(97)00187-5 · Cited by 160
Huang, H.-H., Lu, M.-C., Chen, J.-N., & Lee, C.-T. (2003) · Chemosphere · doi:10.1016/s0045-6535(03)00042-0 · Cited by 159
“The value of pHpzc was measured by the mass titration method (Noh and Schwarz, 1989).”
MethodZhao, L., Ma, J., Sun, Z.-Z., & Zhai, X.-D. (2008) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2008.02.009 · Cited by 158
Biobased Functional Carbon Materials: Production, Characterization, and Applications—A Review
Correa, C. R., & Kruse, A. (2018) · Materials · doi:10.3390/ma11091568 · Cited by 93
“The pHPZC can be determined by acid/base or mass titration methods and is defined as the pH at which the net surface charge is zero [118,119].”
BackgroundMestre, A. S., Hesse, F., Freire, C., Ania, C. O., & Carvalho, A. P. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2018.10.081 · Cited by 57
Sonochemical degradation of propylparaben in the presence of agro-industrial biochar
Nikolaou, S., Vakros, J., Diamadopoulos, E., & Mantzavinos, D. (2020) · Journal of Environmental Chemical Engineering · doi:10.1016/j.jece.2020.104010 · Cited by 27
Metadata
- Authors
- Noh, J. S., & Schwarz, J. A.
- Venue
- Journal of Colloid and Interface Science
- Publisher
- Elsevier BV
- Published
- 1989-06
- Volume
- 130
- Issue
- 1
- Pages
- 157-164
- ISSN
- 0021-9797 (ISSN-L)
- OpenAlex
- W2074249275
- Cited by
- 919
- References
- 25
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.