Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Comparison of autoregression and fast Fourier transform techniques for power spectral analysis of heart period variability of persons with sudden cardiac arrest before and after therapy to increase heart period variability.

Abstract

Clinical studies have used two types of analysis of the power spectral estimates of heart period variability: autoregressive and fast Fourier transform techniques. Controversy exists regarding which method is the most valid. The specific aims of this study are: (1) to describe the power spectra of heart period variability before and after an intervention designed to increase heart period variability in persons after sudden cardiac arrest; (2) to compare the integral of power spectral density between autoregressive and fast Fourier transform techniques within low and high-frequency bands; (3) to compare the magnitude of the spectral peak values determined by autoregressive and fast Fourier transform techniques approaches within low and high-frequency bands; and (4) to compare the aforementioned parameters using 4-minute, 1-hour, and 24-hour blocks of heart period data. Results indicated high correlations between spectral estimations by autoregressive and fast Fourier transform techniques using integrals or peak values within either the low or high-frequency ranges. The autoregressive technique demonstrated better resolution of sharp peaks than the fast Fourier transform technique, and makes a smoother, more interpretable curve. Lastly, people can cognitively change their heart rate variability.

Overview

Integrity signals

Registry

Crossref · 10.1016/0022-0736(92)90109-d

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 14 references

Cited by

See all 24

Metadata

Authors
Cowan, M. J., Burr, R. L., Narayanan, S. B., Buzaitis, A., Strasser, M., & Busch, S.
Affiliations
University of Washington (US)
Corresponding author
Cowan, Marie J.
Venue
Journal of Electrocardiology
Publisher
Elsevier BV
Published
1992
Volume
25
Pages
234-239
ISSN
0022-0736 (ISSN-L)
OpenAlex
W2018802643
Cited by
23
References
14
Citations by year
2022: 2 · 2021: 1 · 2020: 2 · 2017: 2
FWCI
0.70
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Journal of Electrocardiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01nr001970-05)
  • National Institute of Nursing Research (1 R01 NR01970-01A3)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
heart rate variability, autoregressive spectral analysis, fast Fourier transform spectral analysis, power spectral density, cardiac resynchronization therapy
MeSH terms
Biofeedback, Psychology, Fourier Analysis, Heart Arrest, Heart Rate, Humans, Pilot Projects, Recurrence, Signal Processing, Computer-Assisted, Electrocardiography, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of autoregression and fast Fourier transform techniques for power spectral analysis of heart period variability of persons with sudden cardiac arrest before and after therapy to increase heart period variability. https://app.cochat.ai/papers/10.1016/0022-0736(92)90109-d
The paper
Cowan, M. J., Burr, R. L., Narayanan, S. B., Buzaitis, A., Strasser, M., & Busch, S. (1992). Comparison of autoregression and fast Fourier transform techniques for power spectral analysis of heart period variability of persons with sudden cardiac arrest before and after therapy to increase heart period variability. Journal of Electrocardiology. https://doi.org/10.1016/0022-0736(92)90109-d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.