Measurement of cell numbers in microtiter culture plates using the fluorescent dye Hoechst 33258
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
A sensitive fluorimetric assay based on DNA binding of the fluorescent dye Hoechst 33258 was developed to quantitate cell numbers in microtiter plates. The cells were fixed and incubated with the dye solution. The bound dye was extracted with ethanol and fluorescence was measured in a spectrofluorimeter. The method is sensitive for as little as a thousand cells and is particularly useful for the normalization of enzyme-linked immunoassay (ELISA) data obtained from the same cells. Another major advantage of this new technique is that in contrast to previously described methods, it requires commonly available, inexpensive equipment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“which in turn depends on the number of cells.”
From A “Proteomic Ruler” for Protein Copy Number and Concentration Estimation without Spike-in Standards (2014) · cites this paper as [23]
In the citing paper
“DNA concentration was shown to be proportional to the cell count and was successfully used to normalize enzyme activities, transcript and protein amounts, and metabolome data (23–25).”
From A “Proteomic Ruler” for Protein Copy Number and Concentration Estimation without Spike-in Standards (2014) · cites this paper as [23]
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104 · cited 3×
“Plates were read within 1 h of adding the isopropanol (Mosmann, 1983).”
MethodInfluentialA simple, rapid, and sensitive DNA assay procedure
Labarca, C., & Paigen, K. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90165-7 · Cited by 4,901
An improved fluorometric assay for DNA
Hinegardner, R. T. (1971) · Analytical Biochemistry · doi:10.1016/0003-2697(71)90476-3 · Cited by 983 · cited 1×
“One approach utilizes the reaction of 3,5-diaminobenzoic acid (DABA) with the deoxyribose of purine deoxyribonucleotides (Hinegardener, 1971; Johnson-Wint and Hollis, 1982).”
MethodAssay for nanogram quantities of DNA in cellular homogenates
Brunk, C. F., Jones, K. C., & James, T. W. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90690-0 · Cited by 906 · cited 4×
“Other assays are based on the direct binding of fluorochrome dyes to DNA (Brunk et al., 1979; Cesarone et al., 1979; Labarca and Paigen, 1980; Adams and Storrie, 1981; Sterzel et al., 1985; West et al., 1985; Richards et al., 1985; Mates et aL, 1986; McCaffrey et al., 1988; Blaheta et al., 1991; Plummer III et al., 19…”
BackgroundMethodInfluentialImproved microfluorometric DNA determination in biological material using 33258 Hoechst
Cesarone, C. F., Bolognesi, C., & Santi, L. (1979) · Analytical Biochemistry · doi:10.1016/0003-2697(79)90131-3 · Cited by 842 · cited 3×
“Other assays are based on the direct binding of fluorochrome dyes to DNA (Brunk et al., 1979; Cesarone et al., 1979; Labarca and Paigen, 1980; Adams and Storrie, 1981; Sterzel et al., 1985; West et al., 1985; Richards et al., 1985; Mates et aL, 1986; McCaffrey et al., 1988; Blaheta et al., 1991; Plummer III et al., 19…”
BackgroundSimple and rapid fluorimetric method for DNA microassay
Kapuściński, J., & Skoczylas, B. (1977) · Analytical Biochemistry · doi:10.1016/0003-2697(77)90533-4 · Cited by 482
Rage, R., Mitchen, J., & Wilding, G. (1990) · Analytical Biochemistry · doi:10.1016/0003-2697(90)90382-j · Cited by 388 · cited 3×
“, 1985), or the use of an expensive fluorescent microtiter plate reader (Arndt-Jovin and Jovin, 1977; Richards et al., 1985; McCaffrey et al., 1988; Rago et al., 1990; Blaheta et al., 1991), or they cannot be applied to fixed cells (Brunk et al.”
BackgroundMethodAnalysis and sorting of living cells according to deoxyribonucleic acid content.
Arndt-Jovin, D. J., & Jovin, T. M. (1977) · Journal of Histochemistry & Cytochemistry · doi:10.1177/25.7.70450 · Cited by 383 · cited 2×
“, 1985), or the use of an expensive fluorescent microtiter plate reader (Arndt-Jovin and Jovin, 1977; Richards et al., 1985; McCaffrey et al., 1988; Rago et al., 1990; Blaheta et al., 1991), or they cannot be applied to fixed cells (Brunk et al.”
BackgroundWest, D. C., Sattar, A., & Kumar, S. (1985) · Analytical Biochemistry · doi:10.1016/0003-2697(85)90274-x · Cited by 277 · cited 3×
“Other assays are based on the direct binding of fluorochrome dyes to DNA (Brunk et al., 1979; Cesarone et al., 1979; Labarca and Paigen, 1980; Adams and Storrie, 1981; Sterzel et al., 1985; West et al., 1985; Richards et al., 1985; Mates et aL, 1986; McCaffrey et al., 1988; Blaheta et al., 1991; Plummer III et al., 19…”
BackgroundA rapid in situ deoxyribonucleic acid assay for determining cell number in culture and tissue
Johnson‐Wint, B., & Hollis, S. (1982) · Analytical Biochemistry · doi:10.1016/0003-2697(82)90292-5 · Cited by 110 · cited 1×
“One approach utilizes the reaction of 3,5-diaminobenzoic acid (DABA) with the deoxyribose of purine deoxyribonucleotides (Hinegardener, 1971; Johnson-Wint and Hollis, 1982).”
Method
Cited by
A “Proteomic Ruler” for Protein Copy Number and Concentration Estimation without Spike-in Standards
Wiśniewski, J. R., Hein, M. Y., Cox, J., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.037309 · Cited by 690
Sensitive determination of cell number using the CyQUANT® cell proliferation assay
Jones, L. J., Gray, M., Yue, S. T., Haugland, R. P., & Singer, V. L. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00404-5 · Cited by 219
Boura, C., Menu, P., Payan, E., Picart, C., Voegel, J. C., Muller, S., & Stoltz, J. F. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00214-x · Cited by 198
“The initial attachment and growth of HUVEC were measured by fluorescent Hoechst 33342 incorporation into cell DNA according to the procedure of Papadimetriou [27].”
MethodOrwin, E. J., & Hubel, A. (2000) · Tissue Engineering · doi:10.1089/107632700418038 · Cited by 163
Ure, B. M., Niewold, T., Bax, N. M. A., Ham, M., van der Zee, D. C., & van Essen, G. J. (2002) · Surgical Endoscopy · doi:10.1007/s00464-001-9093-7 · Cited by 112
Metadata
- Authors
- Papadimitriou, E., & Lelkes, P. I.
- Corresponding author
- Lelkes, Peter I.
- ORCID
- Lelkes, Peter I.
- Venue
- Journal of Immunological Methods
- Publisher
- Elsevier BV
- Published
- 1993-06
- Volume
- 162
- Issue
- 1
- Pages
- 41-45
- ISSN
- 0022-1759 (ISSN-L)
- OpenAlex
- W2026037773
- Cited by
- 47
- References
- 24
- Citations by year
- 2026: 2 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 3 · 2017: 1 · 2016: 1 · 2014: 2 · 2013: 2
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Immunological Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- American Heart Association
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Cell Image Analysis Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Keywords
- cell counting, Hoechst 33258, DNA binding, fluorometric assay, microplates, cell fixation, low-cost assay
- MeSH terms
- Adrenal Medulla, Animals, Cattle, Cell Count, Cells, Cultured, DNA, Endothelium, Bisbenzimidazole, Spectrometry, Fluorescence, Tetrazolium Salts, Thiazoles, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of cell numbers in microtiter culture plates using the fluorescent dye Hoechst 33258. https://app.cochat.ai/papers/10.1016/0022-1759(93)90405-v
- The paper
- Papadimitriou, E., & Lelkes, P. I. (1993). Measurement of cell numbers in microtiter culture plates using the fluorescent dye Hoechst 33258. Journal of Immunological Methods. https://doi.org/10.1016/0022-1759(93)90405-v
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.