Radiofrequency losses in NMR experiments on electrically conducting samples
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Since sample dielectric loss depends strongly on frequency [6,8,29,9], the vast majority of sample heating occurs from RF irradiation at the 1 H frequency.”
From Using low-E resonators to reduce RF heating in biological samples for static solid-state NMR up to 900MHz (2007) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of Intracellular pH by 31P Magnetic Resonance
Moon, R. B., & Richards, J. H. (1973) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)43389-9 · Cited by 1,189
The sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
Observation of tissue metabolites using 31P nuclear magnetic resonance
Hoult, D. I., Busby, S. J. W., Gadian, D. G., Radda, G. K., Richards, R. E., & Seeley, P. J. (1974) · Nature · doi:10.1038/252285a0 · Cited by 673
Self-citationThe NMR receiver: A description and analysis of design
Hoult, D. I. (1978) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/0079-6565(78)80002-8 · Cited by 426
Burt, C. T., Glonek, T., & Bárány, M. (1976) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)33527-5 · Cited by 339
Human erythrocyte metabolism studies by 1H spin echo NMR
Brown, F. F., Campbell, I. D., Kuchel, P. W., & Rabenstein, D. C. (1977) · FEBS Letters · doi:10.1016/0014-5793(77)80875-2 · Cited by 310
Contraction and recovery of living muscles studied by 31p nuclear magnetic resonance
Gadian, D. G., Dawson, M. J., & Wilkie, D. R. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011835 · Cited by 294
Self-citationPhosphorus nuclear magnetic resonance of perfused working rat hearts
Jacobus, W. E., Taylor, G. J., Hollis, D. P., & Nunnally, R. L. (1977) · Nature · doi:10.1038/265756a0 · Cited by 292
Phosphorus NMR studies on perfused heart
Garlick, P. B., Radda, G. K., Seeley, P. J., & Chance, B. (1977) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(77)91653-9 · Cited by 197
High resolution 31P nuclear magnetic resonance studies of intact yeast cells.
Salhany, J. M., Yamane, T., Shulman, R. G., & Ogawa, S. (1975) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.72.12.4966 · Cited by 160
Cited by
Items 101–198 of 198
Heat transfer in NMR of conductive samples with radiofrequency decoupling
McNair, D. (1981) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(81)90155-4 · Cited by 14
Impedance magnetic resonance imaging with external AC field added to main static field
Yukawa, Y., Iriguchi, N., & Ueno, S. (1999) · IEEE Transactions on Magnetics · doi:10.1109/20.800775 · Cited by 14
Civan, M. M., Williams, S. R., Gadian, D. G., & Rozengurt, E. (1986) · The Journal of Membrane Biology · doi:10.1007/bf01901013 · Cited by 14
Self-citationProtein-inhibitor interaction studies using NMR
Ishima, R. (2015) · Applications of NMR Spectroscopy · doi:10.2174/9781608059621115010007 · Cited by 13
Improving the signal-to-noise ratio of NMR signals by reduction of inductive losses
Kugel, H. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90423-q · Cited by 13
Optimizing ssNMR experiments for dilute proteins in heterogeneous mixtures at high magnetic fields
McNeill, S. A., Gor’kov, P. L., Struppe, J. O., Brey, W. W., & Long, J. R. (2007) · Magnetic Resonance in Chemistry · doi:10.1002/mrc.2146 · Cited by 13
Practical aspects of 15N CPMG transverse relaxation experiments for proteins in solution
Myint, W., Gong, Q., & Ishima, R. (2009) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.20133 · Cited by 13
Blümler, P., & Blümich, B. (1994) · Springer eBooks · doi:10.1007/978-3-642-78483-5_5 · Cited by 13
The crossover surface coil: an efficient in vivo nmr detector
Nagel, T. L., Stolk, J. A., Alderman, D. W., Schoenborn, R. R., & Schweizer, M. P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130209 · Cited by 12
Performance evaluation of whole‐body NMR scanner antenna systems
Sergiadis, G. D. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020403 · Cited by 12
In vivo phosphorus spectroscopy of human skin
Bohning, D. E., Wright, A. C., & SPICER, K. M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350209 · Cited by 12
Song, S., Hotchkiss, R. S., & Ackerman, J. J. H. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250105 · Cited by 12
A nondetuning surface coil, the semitoroid
Assink, R. A., Fukushima, E., Gibson, A. A. V., Rath, A. R., & Roeder, S. B. W. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90120-4 · Cited by 11
Reduction of Human Interaction with Wireless Power Transfer System Using Shielded Loop Coil
Kumazawa, A., Diao, Y., Hirata, A., & Hirayama, H. (2020) · Electronics · doi:10.3390/electronics9060953 · Cited by 10
A technique to increase nmr sensitivity for conductive solutions
Dykstra, R. W. (1989) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(89)90386-7 · Cited by 10
Novikov, A. (2010) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2010.08.001 · Cited by 10
Lumped parameters description of RF losses in ESR experiments on electrically conducting samples
Alecci, M., Gualtieri, G., & Sotgiu, A. (1989) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/22/6/004 · Cited by 10
Contribution à l'amélioration de la sensibilité d'un micro-récepteur RMN implantable
Rosillo, J. T. (2014) · theses.fr (ABES) · doi:10.70675/9b644a56z80c2z4470z8678z46377f4faf92 · Cited by 9
Cho, Z. H., & Yi, J. H. (1995) · Concepts in Magnetic Resonance · doi:10.1002/cmr.1820070202 · Cited by 9
A temperature-jump design for conventional NMR probes
Yushmanov, P. V., & Furó, I. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.04.006 · Cited by 9
Electrostatic shield for the suppression of piezoelectric ringing in pulsed NMR
Pandey, L., & Hughes, D. G. (1984) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(84)90307-x · Cited by 9
Applications of Nuclear Magnetic Resonance to the Study of Myocardial Metabolism and Pharmacology
Matthews, P. M., & Radda, G. K. (1984) · Springer eBooks · doi:10.1007/978-1-4684-4778-1_13 · Cited by 8
Pfitzer, J., Uecker, M., & Scharfetter, H. (2026) · NMR in Biomedicine · doi:10.1002/nbm.70287 · Cited by 8
Imaging of the dielectric resonance effect in high field magnetic resonance imaging
Mihara, H., Iriguchi, N., & Ueno, S. (2005) · Journal of Applied Physics · doi:10.1063/1.1854291 · Cited by 8
RF coils for combined MR and hyperthermia studies: II. MR coil as an hyperthermic applicator
Jayasundar, R., Hall, L. D., & Bleehen, N. M. (2001) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00228-9 · Cited by 8
Lambert, S. A. (2011) · theses.fr (ABES) · doi:10.70675/4b97a871z99bez424az807az5396f4512a20 · Cited by 7
A comparison of three radiofrequency coils for NMR studies of conductive samples
Murphy, M. K., Frnandez, E. J., & Clark, D. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910120311 · Cited by 7
Signal feedback applications in low-field NMR and MRI
Kuzmin, V., & Nacher, P.-J. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106622 · Cited by 7
Li, L., & Kruger, R. A. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/009 · Cited by 7
Changes in probe sensitivity during nmr spectroscopic studies of the perfused rat heart: a warning
Nédélec, J., Saunders, J. K., Morris, P., & Clarke, K. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270214 · Cited by 7
Arakawa, M., Kitahara, T., Inadomi, D., Iikubo, M., Hyakutake, H., Yuasa, K., & Takahashi, I. (2021) · Clinical and Experimental Dental Research · doi:10.1002/cre2.494 · Cited by 6
Reengineered helmet coil for human brain studies at 3 Tesla
Driesel, W., Merkle, H., Hetzer, S., Riemer, T., Zysset, S., & Möller, H. E. (2005) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20052 · Cited by 6
13C‐TmDOTA as versatile thermometer compound for solid‐state NMR of hydrated lipid bilayer membranes
Umegawa, Y., Tanaka, Y., Matsumori, N., & Murata, M. (2015) · Magnetic Resonance in Chemistry · doi:10.1002/mrc.4371 · Cited by 6
Coil optimization for low-field MRI: a dedicated process for small animal preclinical studies
Feuillet, T., Seurin, M. J., Leveneur, O., Viguier, E., & Beuf, O. (2014) · Laboratory Animals · doi:10.1177/0023677214558103 · Cited by 6
NMR Spectroscopy of Encapsulated Proteins Dissolved in Low Viscosity Fluids
Wand, A. J., Babu, C. R., Flynn, P. F., & Milton, M. J. (2006) · Kluwer Academic Publishers eBooks · doi:10.1007/0-306-47936-2_6 · Cited by 5
A wireless axial pair resonator
Maeda, H., Toyooka, N., & Okawara, H. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290423 · Cited by 5
Nuclear magnetic resonance for measurement
Mackenzie, I. S. (1986) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/19/5/001 · Cited by 5
Three-dimensional microscopy toward in Vivo cellular imaging using NMR tomography
Cho, Z. H., Ahn, C. B., Juh, S. C., Friedenberg, R. M., Jacobs, R. E., & Fraser, S. E. (1990) · Journal of Visual Communication and Image Representation · doi:10.1016/1047-3203(90)90016-o · Cited by 5
Electric fields and losses in lumped element resonators for ESR spectroscopy
Sotgiu, A., Momo, F., Gualtieri, G., & Adriani, O. (1987) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/20/12/013 · Cited by 5
Protein Dynamics Revealed by CPMG Dispersion
Ishima, R., & Bagby, S. (2018) · Springer eBooks · doi:10.1007/978-3-319-28388-3_44 · Cited by 4
New unifying metric for NMR/MRI probe evaluation based on optimized solenoid coil geometry
Tritrakarn, T., Yamamoto, K., Takahashi, M., & Okamura, T. (2023) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2023.107602 · Cited by 4
Efficiency estimation for single-coil, separate-input, double-tuned NMR probes
Najim, E., & Grivet, J. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90027-q · Cited by 4
Analysis of Conservative and Magnetically Induced Electric Fields in a Low-Frequency Birdcage Coil
Park, B. S., Rajan, S. S., Collins, C. M., & Angelone, L. M. (2013) · Journal of Electromagnetic Analysis and Application · doi:10.4236/jemaa.2013.57043 · Cited by 4
The effect of coil geometry on the RF heating of saline phantoms: applications to in vivo NMR
Hughes, D. G., Antolak, J. A., & Allen, P. S. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/11/004 · Cited by 4
Boesiger, P., Buchli, R., SANER, M., & Meier, D. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49605.x · Cited by 4
Sergiadis, G. D., Sakellaris, J. K., & Kriezis, E. E. (1988) · IEEE Transactions on Medical Imaging · doi:10.1109/42.14522 · Cited by 4
Guisiano, J.-C. (2011) · theses.fr (ABES) · doi:10.70675/79f65841z29ebz480dza1fezf991a7b9f547 · Cited by 4
Principles and Horizons of Magnetic Resonance Imaging
Ueno, S., & Iriguchi, N. (2000) · Advances in electromagnetic fields in living systems · doi:10.1007/978-1-4615-4203-2_2 · Cited by 3
A 1H Background-Free 3D Printing Digital Light Processing Resin for Applications in NMR Spectroscopy
Costa, P. M., Steiner, K., Lysak, D. H., Pellizzari, J., Wolff, W. W., Downey, K., Ronda, K., Moxley‐Paquette, V., Meulen, O. V., Terry, C., et al. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c03472 · Cited by 3
Meng, F., Guo, Y., He, W., & Xu, Z. (2024) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2024.107636 · Cited by 3
A Low-Cost, High Quality MRI Breast Scanner Using Prepolarization
Macovski, A. (1999) · Defense Technical Information Center (DTIC) · doi:10.21236/ada390614 · Cited by 3
Sýkora, S. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90384-x · Cited by 3
Hybrid rf coil for nuclear magnetic resonance imaging
Luca, F. D., Luzzi, M. F., Crescenzi, A., Simone, B. C. D., Campanella, R., Casieri, C., & Maraviglia, B. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90404-x · Cited by 3
Signal-to-noise improvement in mid-field MRI surface coils: A degree in plumbing?
WALKER, P. M., Robin-Lherbier, B., Escanyé, J. M., & Robert, J. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90537-v · Cited by 3
Salmón, C. E. G. (2005) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.76.2005.tde-12032005-182218 · Cited by 2
Feuillet, T. (2014) · theses.fr (ABES) · doi:10.70675/b788a067zef15z4080zbf90z6e4a45219253 · Cited by 2
Kwan, R. K. S. (1997) · doi:10.82308/43987 · Cited by 2
Couty, M. (2012) · theses.fr (ABES) · doi:10.70675/3e3ea22cz33aez44b9zacb9z151d3dc5d2a8 · Cited by 2
NMR Methods in Studies of Brain Ischemia
Chang, L., & James, T. L. (1992) · Biological magnetic resonance · doi:10.1007/978-1-4757-9477-9_3 · Cited by 2
A continuously variable field of view surface coil
Duensing, R., Fitzsimmons, J. R., Sanford, D., & Vazquez, J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130305 · Cited by 2
Hill, H. D. W. (2007) · Wiley eBooks · doi:10.1002/9780470034590.emrstm0415 · Cited by 2
Gathering Metabolic Information Using 13C and 1H High Resolution Spectra of Living Systems
Alger, J. R. (1986) · Springer eBooks · doi:10.1007/978-94-009-4580-7_16 · Cited by 2
Harpen, M. D. (1989) · Physics in Medicine and Biology · doi:10.1088/0031-9155/34/7/005 · Cited by 2
Pellicer-Guridi, R. (2018) · The University of Queensland · doi:10.14264/uql.2018.707 · Cited by 1
Joseph, D., Kümmerle, R., Freytag, N., & Griesinger, C. (2026) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2026.108081 · Cited by 1
Non-invasive, non-contact conductivity measurement using radiofrequency probe loading
Wangchuk, T., Aguilera, A. R., & Balcom, B. J. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/ae0e9a · Cited by 1
Fundamental SNR and SAR limitations in very low field MRI
Chapple, E. C. M. (2006) · Summit (Simon Fraser University) · Cited by 1
Multinuclear study of RF losses in NaCl/D2O solutions
Mao, X. A., & Holz, M. (1994) · Applied Magnetic Resonance · doi:10.1007/bf03162642 · Cited by 1
Noise Detected NMR Spectroscopy
Chandra, K. (2014) · NOT FOUND REPOSITORY (Indian Institute of Science Bangalore) · Cited by 1
Designing a solenoid coil of high sensitivity for a cryogenic probe of a novel split magnet
Park, M., Kawasaki, K., Okada, M., & Kitaguchi, H. (2010) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.20156 · Cited by 1
SAR measurement and distribution in defined body volumes through the development of MRI phantoms
Russo, A. A., Valeri, S., Baccani, G., Delia, F., & Delia, R. (2016) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2016.7533700 · Cited by 1
Terawatsakul, N., Saberkari, A., Puttisong, Y., & Madec, M. (2025) · Electronics · doi:10.3390/electronics14020398 · Cited by 1
Sample-induced cross-coil coupling. Implications for magnetic-resonance-imaging quadrature coils
Harpen, M. D. (1991) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(91)90109-7 · Cited by 1
3D-Printed Microstrip Resonators for 4.7T MRI
Javidmehr, S. (2015) · ERA: Education and Research Archive (University of Alberta) · doi:10.7939/r35717v47 · Cited by 1
Paisner, S. W., Janicke, M. T., Kaseman, D. C., Frankle, R. K., Yoder, J. L., Alvarez, M. A., Espy, M. A., & Williams, R. F. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05603 · Cited by 1
48th Rocky Mountain Conference on Analytical Chemistry
(2006) · Rocky Mountain Conference on Analytical Chemistry · doi:10.56902/rmcmr.2006.48.1 · Cited by 1
Biomagnetic Imaging: Principles of Magnetic Resonance Imaging and Emerging Techniques in Progress
Ueno, S., & Iriguchi, N. (2005) · Wiley eBooks · doi:10.1002/9783527619252.ch4n
Untersuchung von Hühnereiern mittels kernmagnetischer Resonanzspektroskopie (NMR)
Wenig, S. (2022) · Repository KITopen (Karlsruhe Institute of Technology) · doi:10.5445/ir/1000140414
Utilization of NMR surface coil techniques to study muscle fatigue
Lee, J. W. K. (2011) · cIRcle (University of British Columbia) · doi:10.14288/1.0059362
Guan, J., Xie, X. J., Xie, J., Wang, Y., Zhai, Z., Li, Z., Yao, K., & Sun, H. (2025) · Review of Scientific Instruments · doi:10.1063/5.0287557
Diseño de un sistema de bobinas de RF para aplicaciones de imagen de resonancia magnética en flúor
Valverde, P. V. (2023) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.72581
Protein Dynamics Revealed by CPMG Dispersion
Ishima, R., & Bagby, S. (2016) · Springer eBooks · doi:10.1007/978-3-319-28275-6_44-1
Faculty Opinions recommendation of Cell water dynamics on multiple time scales.
Härd, T. (2010) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.2900956.2569054
Aspects of NMR imaging and in vivo spectroscopy
Talagala, S. L. (2010) · cIRcle (University of British Columbia) · doi:10.14288/1.0059466
Dielectric losses in NMR studies on sintered aluminum powders
Brettell, J. M. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90038-7
RF Electric Field Mapping in MR Coils with a Quartz Crystal
Wang, D., & LEIGH, J. S. J. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910330616
NMR Studies of Colloidal Systems in and out of Equilibrium
Yushmanov, P. V. (2006) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
High magnetic field MRI system-superconducting magnet for the MRI system.
Maeda, H., Urata, M., & Satoh, K. (1990) · TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan) · doi:10.2221/jcsj.25.362
Dour, O. L., Vester, M., Henninger, P., & Renz, W. (1995) · Springer eBooks · doi:10.1007/978-1-4615-1961-4_58
Abstracts (Continue in Part V)
(1983) · Proceedings of the Society of Magnetic Resonance in Medicine · doi:10.1002/mrmp.22419830106
NMRおよびMRI用RFコイルの統一評価指標と性能向上に関する研究
トリトラカーン, テ., & Tritrakarn, T. (2024) · Institutional Repositories DataBase (IRDB)
RF coils development and sequences optimisation for hyperpolarised 129 Xe MRI
Puddu, C. (2024) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
下顎前突患者における筋機能MRIおよび31P-MRSを用いた咀嚼筋の分子イメージング
Arakawa, M. (2022) · Institutional Repositories DataBase (IRDB)
MEMS-based reconfigurable endoluminal MRI coils
Raki, H. (2020) · theses.fr (ABES) · doi:10.70675/0c1084e0zf322z404fz8088z91b925788d85
Dielectric antennas for ultra-high field magnetic resonance microscopy
Moussu, M. A. C. (2021) · theses.fr (ABES) · doi:10.70675/c6240f08z0a21z40e8zabaez3b094d62c83c
NMRおよびMRI用RFコイルの統一評価指標と性能向上に関する研究
Tritrakarn, T. (2024) · Institutional Repositories DataBase (IRDB)
Toward MRI microimaging of single biological cells
Seeber, D. A. (2001) · OhioLink ETD Center (Ohio Library and Information Network)
Metadata
- Authors
- Gadian, D. G., & Robinson, F. N. H.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1979-05
- Volume
- 34
- Issue
- 2
- Pages
- 449-455
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2066561387
- Cited by
- 172
- References
- 11
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.