Sensitivity of magnetic-resonance current-density imaging
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-Dimensional Signal and Image Processing
Lim, J. S. (1989) · Medical Entomology and Zoology · Cited by 2,561
Haykin, S. (1978) · Cited by 1,857
Analysis of the phase unwrapping algorithm
Itoh, K. (1982) · Applied Optics · doi:10.1364/ao.21.002470 · Cited by 887
The sensitivity of the zeugmatographic experiment involving human samples
Hoult, D. I., & Lauterbur, P. C. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90019-2 · Cited by 776
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
In vivo detection of applied electric currents by magnetic resonance imaging
Joy, M., Scott, G., & Henkelman, M. (1989) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(89)90328-7 · Cited by 275
Self-citationRadiofrequency losses in NMR experiments on electrically conducting samples
Gadian, D. G., & Robinson, F. N. H. (1979) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(79)90023-4 · Cited by 172
Electrochemical Treatment of Cancer. I: Variable Response to Anodic and Cathodic Fields
Nordenström, B. (1989) · American Journal of Clinical Oncology · doi:10.1097/00000421-198912000-00015 · Cited by 61
Data extrapolation for truncation artifact removal
Constable, R. T., & Henkelman, R. M. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170115 · Cited by 56
Self-citationOptimal Electrode Designs for Electrosurgery, Defibrillation, and External Cardiac Pacing
Kim, Y., Fahy, J. B., & Tupper, B. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325778 · Cited by 44
Cited by
Extracellular Total Electrolyte Concentration Imaging for Electrical Brain Stimulation (EBS)
Sajib, S. Z. K., Lee, M. B., Kim, H. J., Woo, E. J., & Kwon, O. I. (2018) · Scientific Reports · doi:10.1038/s41598-017-18515-3 · Cited by 491
Kwon, O., Woo, E. J., Yoon, J.-R., & Seo, J. K. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979355 · Cited by 281
The Importance of Electric Field Distribution for Effective in Vivo Electroporation of Tissues
Miklavčič, D., Beravs, K., Šemrov, D., Čemažar, M., Demšar, F., & Serša, G. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77924-x · Cited by 273
Bodurka, J., & Bandettini, P. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10159 · Cited by 178
Visualizing tissue compliance with MR imaging
Plewes, D. B., Betty, I., Urchuk, S. N., & Soutar, I. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050620 · Cited by 166
Yang, Y., Gu, H., Zhan, W., Xu, S., Silbersweig, D. A., & Stern, E. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10196 · Cited by 77
“A threshold can be derived to determine the minimum strength of the susceptibility gradient that would cause severe signal loss, analogous to the method used in a previous study (41), although for an entirely different application.”
Method
Metadata
- Authors
- Scott, G. C., Joy, M. L. G., Armstrong, R. L., & Henkelman, R. M.
- Venue
- Journal of Magnetic Resonance (1969)
- Publisher
- Elsevier BV
- Published
- 1992-04
- Volume
- 97
- Issue
- 2
- Pages
- 235-254
- ISSN
- 0022-2364 (ISSN-L)
- OpenAlex
- W2064490468
- Cited by
- 248
- References
- 10
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.