The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes
Open accessAbstract
A novel method based on selective detection of rapidly changing Δ B0 magnetic fields and suppression of slowly changing Δ B0 fields is presented. The ultimate goal of this work is to present a method that may allow detection of transient and subtle changes in B0 in cortical tissue associated with electrical currents produced by neuronal activity. The method involves the detection of NMR phase changes that occur during a single‐shot spin‐echo (SE) echo‐planar sequence (EPI) echo time. SE EPI effectively rephases all changes in B0 that occur on a time scale longer than the echo time (TE) and amplifies all Δ B0 changes that occur during TE/2. The method was tested on a phantom that contains wires in which current can be modulated. The sensitivity and flexibility of the technique was demonstrated by modulation of the temporal position and duration of the stimuli‐evoked transient magnetic field relative to the 180 RF pulse in the imaging sequence—requiring precise stimulus timing. Currently, with this method magnetic field changes as small as 2 × 10−10 T (200 pT) and lasting for 40 msec can be detected. Implications for direct mapping of brain neuronal activity with MRI are discussed. Magn Reson Med 47:1052–1058, 2002. Published 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AFNI: Software for analysis and visualization of functional magnetic resonance neuroimages
Cox, R. W. (1996) · Computers and Biomedical Research · doi:10.1006/cbmr.1996.0014 · Cited by 10,913
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Self-citation
Cited by
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Modalities, Modes, and Models in Functional Neuroimaging
Friston, K. J. (2009) · Science · doi:10.1126/science.1174521 · Cited by 489
Renewal of the Neurophysiology of Language: Functional Neuroimaging
Démonet, J.-F., Thierry, G., & Cardebat, D. (2005) · Physiological Reviews · doi:10.1152/physrev.00049.2003 · Cited by 418
MRI in multiple sclerosis: current status and future prospects
Bakshi, R., Thompson, A. J., Rocca, M. A., Pelletier, D., Dousset, V., Barkhof, F., Inglese, M., Guttmann, C. R., Horsfield, M. A., & Filippi, M. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70137-6 · Cited by 348
Analyzing for information, not activation, to exploit high-resolution fMRI
Kriegeskorte, N., & Bandettini, P. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.022 · Cited by 270
Self-citation
Metadata
- Authors
- Bodurka, J., & Bandettini, P. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2002-06
- Volume
- 47
- Issue
- 6
- Pages
- 1052-1058
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2033214525
- Cited by
- 178
- References
- 3
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes. https://app.cochat.ai/papers/10.1002/mrm.10159
- The paper
- Bodurka, J., & Bandettini, P. A. (2002). Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.10159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.