Low oxygen delivery produced by anemia, hypoxia, and low cardiac output
Abstract
In pentobarbital-anesthetized dogs, oxygen delivery (DO2) was measured by thermodilution cardiac output and cooximeter determined oxygen content, while oxygen consumption (VO2) was measured independently by spirometry. Oxygen delivery was decreased by isovolemic dilutional anemia, breathing hypoxic gas mixtures, or cardiac tamponade to reduce cardiac output. Baseline VO2 (cc/kg/min) for the three groups was 5.9 +/- 0.7 (anemia), 5.4 +/- 0.4 (hypoxia), and 5.6 +/- 0.1 (low C.O.) (NS). A critical level of oxygen delivery (DO2crit) was found at 9-10 cc/kg/min (anemia), 10-11 cc/kg/min (hypoxia), and 9-10 cc/kg/min (low C.O.) (NS.). Below this level, VO2 fell (became supply dependent) and lactic acidosis occurred, regardless of the mechanism of impaired oxygen delivery.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
If effective fluid resuscitation ensures adequate intravascular volume, oxygen extraction at the tissue level can compensate for the reduction in arterial oxygen content until anemia becomes very severe.
“If effective fluid resuscitation ensures adequate intravascular volume, oxygen extraction at the tissue level can compensate for the reduction in arterial oxygen content until anemia becomes very severe (81, 82).”
From Placental abruption at near-term and term gestations: Pathophysiology, epidemiology, diagnosis, and management (2023) · cites this paper as [82]
Citations
Cites
Oxygen delivery and uptake in dogs during anemic and hypoxic hypoxia
Cain, S. M. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.42.2.228 · Cited by 481
Critical level of oxygen delivery in anesthetized man
Shibutani, K., Komatsu, T., Kubal, K. S., Sanchala, V. T., Kumar, V. N., & BIZZARRI, D. V. (1983) · Critical Care Medicine · doi:10.1097/00003246-198308000-00010 · Cited by 379
Thermodilution cardiac output: A critical analysis and review of the literature
Levett, J. M., & Replogle, R. L. (1979) · Journal of Surgical Research · doi:10.1016/0022-4804(79)90159-8 · Cited by 244
Fetal oxygen uptake, oxygenation, and acid-base balance as a function of uterine blood flow
Wilkening, R. B., & Meschia, G. (1983) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1983.244.6.h749 · Cited by 182
The effect of reducing umbilical blood flow on fetal oxygenation
Itskovitz, J., LaGamma, E. F., & Rudolph, A. M. (1983) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(83)90684-1 · Cited by 167
Oxygen delivery and utilization in hypothermic dogs
Gutiérrez, G., Warley, A., & Dantzker, D. R. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.3.751 · Cited by 80
A critical value for O2 transport in the rat
Adams, R. P., Dieleman, L. A., & Cain, S. M. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.3.660 · Cited by 66
Hyperlactatemia due to arterial hypoxemia or reduced cardiac output, or both
Simmons, D. H., Alpas, A. P., Tashkin, D. P., & Coulson, A. (1978) · Journal of Applied Physiology · doi:10.1152/jappl.1978.45.2.195 · Cited by 53
Pepe, P. E., & Culver, B. H. (1985) · PubMed · doi:10.1164/arrd.1985.132.4.788 · Cited by 50
Oxygen Transport and Metabolism in the Conscious Lamb: The Effects of Hypoxemia
Moss, M. S., Moreau, G., & Lister, G. (1987) · Pediatric Research · doi:10.1203/00006450-198708000-00016 · Cited by 38
Postnatal changes in critical cardiac output and oxygen transport in conscious lambs
Fahey, J. T., & Lister, G. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.253.1.h100 · Cited by 34
Oxygen Delivery and Uptake in the Adult Respiratory Distress Syndrome
Annat, G. J., Viale, J., Percival, C., et al. (2015) · American Review of Respiratory Disease · Cited by 33
Independent measurement of oxygen consumption and oxygen delivery
Cilley, R. E., Polley, T. Z., Zwischenberger, J. B., et al. (1989) · Journal of Surgical Research · doi:10.1016/0022-4804(89)90114-5 · Cited by 27
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Brandt, J. S., & Ananth, C. V. (2023) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2022.06.059 · Cited by 115
Metadata
- Authors
- Cilley, R. E., Scharenberg, A. M., Bongiorno, P. F., Guire, K. E., & Bartlett, R. H.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Cilley, Robert E.
- Venue
- Journal of Surgical Research
- Publisher
- Elsevier BV
- Published
- 1991-11
- Volume
- 51
- Issue
- 5
- Pages
- 425-433
- ISSN
- 0022-4804 (ISSN-L)
- OpenAlex
- W2028652466
- Cited by
- 54
- References
- 13
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2023: 4 · 2020: 2 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 5 · 2014: 2 · 2013: 1 · 2012: 3
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Surgical Research (publishedVersion)
- PubMed (publishedVersion)
- Deep Blue (University of Michigan) (submittedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Physiology (medical) › Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- oxygen delivery, anemia, hypoxia, low cardiac output, oxygen consumption, critical oxygen delivery, lactic acidosis, cardiac tamponade, dilutional anemia, hypoxic gas mixture
- MeSH terms
- Anemia, Animals, Hypoxia, Cardiac Output, Low, Dogs, Lactates, Oxygen Consumption, Thermodilution, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review