Blood Gas Analysis of Placental and Uterine Blood During Cesarean Delivery
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To measure blood gases in uterine venous blood and maternal and fetal blood from the placenta, and to characterize gas exchange in the intervillous space. METHODS: Blood gas measurements were performed immediately after collecting placental and uterine blood from the subchorial and marginal lakes, from the chorionic vein and artery in the placenta in utero, and from the uterine vein during 12 cesarean deliveries. RESULTS: The mean oxygen pressure (PO2) values of the chorionic vein and subchorial lake were 28.7 +/- 6.0 and 29.9 +/- 7.5 mmHg, respectively, with a difference of 1.2 mmHg. The individual data for PO2 of the chorionic vein exceeded those of the subchorial lake in five subjects and were almost equal in two of the 12 subjects. The mean values of carbon dioxide pressure (PCO2) and bicarbonate were greater in the chorionic vein than in the subchorial lake, but the mean pH values were the same in the two groups. The mean values of blood gas analysis were not different between subchorial and marginal lakes with similar blood composition. The mean PO2 of the uterine vein in ten subjects was 45.9 mmHg, significantly higher than that of the subchorial lake. CONCLUSIONS: The human placenta may be defined as a multivillous model with a high degree of oxygen transfer. Arteriovenous anastomoses are suspected in the pregnant uterus beyond 37 weeks' gestation. Subchorial and marginal lakes contain similar admixed blood, which circulates and performs gas exchange.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current topic: Comparative physiology of placental oxygen transport
Wilkening, R. B., & Meschia, G. (1992) · Placenta · doi:10.1016/0143-4004(92)90002-b · Cited by 82
Cited by
Ahmad, S., & Ahmed, A. (2004) · Circulation Research · doi:10.1161/01.res.0000147365.86159.f5 · Cited by 517
Hung, T.-H., Skepper, J. N., Charnock-Jones, D. S., & Burton, G. J. (2002) · Circulation Research · doi:10.1161/01.res.0000024411.22110.aa · Cited by 397
Jauniaux, E., Watson, A., & Burton, G. (2001) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2001.111935 · Cited by 318
Hypoxia and Reoxygenation: a Possible Mechanism for Placental Oxidative Stress in Preeclampsia
Hung, T.-H., & Burton, G. J. (2006) · Taiwanese Journal of Obstetrics and Gynecology · doi:10.1016/s1028-4559(09)60224-2 · Cited by 285
Improving pregnancy outcomes in humans through studies in sheep
Morrison, J. L., Berry, M. J., Botting, K. J., Darby, J. R. T., Frasch, M. G., Gatford, K. L., Giussani, D. A., Gray, C. L., Harding, R., Herrera, E. A., et al. (2018) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00391.2017 · Cited by 171
“In a human study examining uterine-umbilical saturation and venous PO2 differences, uterine and umbilical venous blood was sampled during cesarean section (135), and the normal uterine-umbilical PO2 difference near term was determined to be ~10 Torr, which is comparable to the ~14-Torr uterineumbilical venous PO2 diff…”
Background
Metadata
- Authors
- FUJIKURA, T., & YOSHIDA, J.
- Venue
- Obstetrics & Gynecology
- Published
- 1996-01
- Volume
- 87
- Issue
- 1
- Pages
- 133-136
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1992360640
- Cited by
- 46
- References
- 1
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.