The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Accuracy of Transvaginal Ultrasonography in the Diagnosis of Endometrial Abnormalities
Abstract
OBJECTIVE: To evaluate the diagnostic accuracy of transvaginal ultrasonography for endometrial abnormalities in women with abnormal uterine bleeding. METHODS: In a prospective study, 136 consecutive patients underwent transvaginal ultrasonography, hysteroscopy, and endometrial sampling through suction curettage or directed biopsy. The ultrasonographic findings were evaluated on the basis of the final diagnosis established by hysteroscopy and histologic examination. Receiver operating characteristic curve analysis and likelihood ratios were used. Likelihood ratios algebraically combine sensitivity and specificity to describe more than the independent values themselves, specifically the change in odds favoring disease given a particular test result. RESULTS: In 21 of the 136 patients, hysteroscopy detected polyps or submucous myomas, which curettage failed to detect. In 67 premenopausal women, ultrasonography demonstrated a sensitivity in diagnosing endometrial abnormalities of 88% and a specificity of 68%, using a cutoff point of 5 mm of single-layer endometrial thickness. The positive likelihood ratio was 2.8 (95% confidence interval [CI] 1.66-4.55) and negative likelihood ratio 0.18 (95% CI 0.07-0.46). In 69 postmenopausal women, using a cutoff point of 3 mm, the sensitivity, specificity, positive likelihood ratio and negative likelihood ratio were 97%, 74%, 3.7 (95% CI 2.18-6.38), and 0.04 (95% CI 0.01-0.28) respectively. CONCLUSIONS: Transvaginal ultrasonography is an excellent first-step diagnostic method of excluding the endometrial abnormalities in women with postmenopausal bleeding but is of limited use in premenopausal women with irregular bleeding. Ultrasonography may reduce the number of invasive endometrial investigations by approximately 40%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Likelihood ratios with confidence: Sample size estimation for diagnostic test studies
Simel, D. L., Samsa, G. P., & Matchar, D. B. (1991) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(91)90128-v · Cited by 932
Cited by
Endovaginal Ultrasound to Exclude Endometrial Cancer and Other Endometrial Abnormalities
Smith-Bindman, R., Kerlikowske, K., Feldstein, V. A., Subak, L., Scheidler, J., Segal, M., Brand, R., & Grady, D. (1998) · JAMA · doi:10.1001/jama.280.17.1510 · Cited by 736
Leone, F. P. G., Timmerman, D., Bourne, T., Valentin, L., Epstein, E., Goldstein, S. R., Marret, H., Parsons, A. K., Gull, B., Istre, O., et al. (2010) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7487 · Cited by 341
Sonohysterography: a prospective survey of results and complications in 81 patients
Bonnamy, L., Marret, H., Perrotin, F., Body, G., Berger, C., & Lansac, J. (2002) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(01)00567-x · Cited by 336
Timmermans, A., Opmeer, B. C., Khan, K. S., Bachmann, L. M., Epstein, E., Clark, T. J., Gupta, J. K., Bakour, S. H., van den Bosch, T., van Doorn, H. C., et al. (2010) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3181e3e7e8 · Cited by 312
Self-citationClark, T. (2002) · BJOG: An International Journal of Obstetrics and Gynaecology · doi:10.1016/s1470-0328(02)01088-1 · Cited by 292
Metadata
- Authors
- Dijkhuizen, F.
- Venue
- Obstetrics & Gynecology
- Published
- 1996-03
- Volume
- 87
- Issue
- 3
- Pages
- 345-349
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2137320515
- Cited by
- 194
- References
- 1
- FWCI
- 10.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Accuracy of Transvaginal Ultrasonography in the Diagnosis of Endometrial Abnormalities. https://app.cochat.ai/papers/10.1016/0029-7844(95)00450-5
- The paper
- Dijkhuizen, F. (1996). The Accuracy of Transvaginal Ultrasonography in the Diagnosis of Endometrial Abnormalities. Obstetrics & Gynecology. https://doi.org/10.1016/0029-7844(95)00450-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.