CoChat

The DOI matches its Crossref record, with a small difference in title or year; 32 of the 32 references it cites were found in a registry or an index.

Endometrial Thickness Measurement for Detecting Endometrial Cancer in Women With Postmenopausal Bleeding: A Systematic Review and Meta-Analysis

Timmermans, Anne, Opmeer, Brent C., Khan, Khalid S., Bachmann, Lucas M., Epstein, Elisabeth, Clark, T. Justin, Gupta, Janesh K., Bakour, Shagaf H., van den Bosch, Thierry, van Doorn, Helena C., Cameron, Sharon T., Giusa, M. Gabriella, Dessole, Stefano, Dijkhuizen, F. Paul H. L. J., ter Riet, Gerben, Mol, Ben W. J. · 2010 · Obstetrics & Gynecology

Abstract

OBJECTIVE: To estimate the accuracy of endometrial thickness measurement in the detection of endometrial cancer among women with postmenopausal bleeding with individual patient data using different meta-analytic strategies. DATA SOURCES: Original data sets of studies detected after reviewing the included studies of three previous reviews on this subject. An additional literature search of published articles using MEDLINE databases was preformed from January 2000 to December 2006 to identify articles reporting on endometrial carcinoma and sonographic endometrial thickness measurement in women with postmenopausal bleeding. METHODS OF STUDY SELECTION: We identified 90 studies reporting on endometrial thickness measurements and endometrial carcinoma in women with postmenopausal bleeding. TABULATION, INTEGRATION, AND RESULTS: We contacted 79 primary investigators to obtain the individual patient data of their reported studies, of which 13 could provide data. Data on 2,896 patients, of which 259 had carcinoma, were included. Several approaches were used in the analyses of the acquired data. First, we performed receiver operator characteristics (ROC) analysis per study, resulting in a summary area under the ROC curve (AUC) calculated as a weighted mean of AUCs from original studies. Second, individual patient data were pooled and analyzed with ROC analyses irrespective of study with standardization of distributional differences across studies using multiples of the median and by random effects logistic regression. Finally, we also used a two-stage procedure, calculating sensitivities and specificities for each study and using the bivariate random effects model to estimate summary estimates for diagnostic accuracy. This resulted in rather comparable ROC curves with AUCs varying between 0.82 and 0.84 and summary estimates for sensitivity and specificity located along these curves. These curves indicated a lower AUC than previously reported meta-analyses using conventional techniques. CONCLUSION: Previous meta-analyses on endometrial thickness measurement probably have overestimated its diagnostic accuracy in the detection of endometrial carcinoma. We advise the use of cutoff level of 3 mm for exclusion of endometrial carcinoma in women with postmenopausal bleeding.

Overview

Integrity signals

Registry

Crossref · 10.1097/aog.0b013e3181e3e7e8

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Cited by

See all 312

Metadata

Authors
Timmermans, A., Opmeer, B. C., Khan, K. S., Bachmann, L. M., Epstein, E., Clark, T. J., Gupta, J. K., Bakour, S. H., van den Bosch, T., van Doorn, H. C., Cameron, S. T., Giusa, M. G., Dessole, S., Dijkhuizen, F. P. H. L. J., ter Riet, G., & Mol, B. W. J.
Affiliations
Lund University (SE)
Venue
Obstetrics & Gynecology
Published
2010-07
Volume
116
Issue
1
Pages
160-167
ISSN
0029-7844 (ISSN-L)
OpenAlex
W2039203961
Cited by
312
References
31
Citations by year
2026: 14 · 2025: 13 · 2024: 19 · 2023: 16 · 2022: 23 · 2021: 21 · 2020: 46 · 2019: 20 · 2018: 28 · 2017: 17 · 2016: 21 · 2015: 18 · 2014: 12 · 2013: 14 · 2012: 11
FWCI
18.77
Type
journal article
Language
en
Open access
closed
Locations
  • Obstetrics and Gynecology (publishedVersion)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
  • EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
  • Lund University Publications (Lund University) (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
  • UNIFESP Institutional Repository (Universidade Federal de São Paulo) (submittedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion)
Topics
  • Health Sciences › Medicine › Obstetrics and Gynecology › Endometrial and Cervical Cancer Treatments
  • Health Sciences › Medicine › Obstetrics and Gynecology › Gynecological conditions and treatments
  • Health Sciences › Medicine › Epidemiology › Cervical Cancer and HPV Research
Keywords
endometrial cancer, postmenopausal bleeding, diagnostic accuracy, transvaginal ultrasound, individual patient data, sensitivity and specificity, cut-off values
MeSH terms
Endometrium, Female, Humans, ROC Curve, Sensitivity and Specificity, Ultrasonography, Uterine Hemorrhage, Endometrial Neoplasms, Postmenopause

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Endometrial Thickness Measurement for Detecting Endometrial Cancer in Women With Postmenopausal Bleeding: A Systematic Review and Meta-Analysis. https://app.cochat.ai/papers/10.1097/aog.0b013e3181e3e7e8
The paper
Timmermans, A., Opmeer, B. C., Khan, K. S., Bachmann, L. M., Epstein, E., Clark, T. J., Gupta, J. K., Bakour, S. H., van den Bosch, T., van Doorn, H. C., Cameron, S. T., Giusa, M. G., Dessole, S., Dijkhuizen, F. P. H. L. J., ter Riet, G., & Mol, B. W. J. (2010). Endometrial Thickness Measurement for Detecting Endometrial Cancer in Women With Postmenopausal Bleeding: A Systematic Review and Meta-Analysis. Obstetrics & Gynecology. https://doi.org/10.1097/aog.0b013e3181e3e7e8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.