The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diffraction-limited imaging in a scanning transmission x-ray microscope
Abstract
We report the characterization of a scanning transmission x-ray microscope which makes use of an undulator x-ray source, a high resolution scanning stage, and a 45 nm outer zone width, >10% diffraction efficiency Fresnel zone plate as the probe-forming optic at soft x-ray wavelengths (typically 3.64 nm). The modulation transfer function of the instrument is in good agreement with theory; it remains above 0.1 to spatial frequencies corresponding to structures as small as 25 nm. This spatial frequency limit is the best obtained in any soft x-ray microscope, and is about a factor of ten better than what is attained in conventional or confocal visible light microscopes. By deconvolving the zone plate point spread function from the image, the microscope has been used to resolve 36 nm features in a gold test object. The microscope is used primarily for the study of thick, hydrated biological specimens with minimal radiation dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging biological specimens with high-intensity soft x rays
Solem, J. C. (1986) · Journal of the Optical Society of America B · doi:10.1364/josab.3.001551 · Cited by 92
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Henderson, R. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350000305x · Cited by 1,194
Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source
Kilcoyne, A. L. D., Tyliszczak, T., Steele, W. F., Fakra, S., Hitchcock, P., Franck, K., Anderson, E., Harteneck, B., Rightor, E. G., Mitchell, G. E., et al. (2003) · Journal of Synchrotron Radiation · doi:10.1107/s0909049502017739 · Cited by 692
Self-citationSoft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672
Self-citationX-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Metadata
- Authors
- Jacobsen, C., Williams, S., Anderson, E., Browne, M. T., Buckley, C. J., Kern, D., Kirz, J., Rivers, M., & Zhang, X.
- Venue
- Optics Communications
- Publisher
- Elsevier BV
- Published
- 1991-11
- Volume
- 86
- Issue
- 3-4
- Pages
- 351-364
- ISSN
- 0030-4018 (ISSN-L)
- OpenAlex
- W2072272320
- Cited by
- 244
- References
- 1
- FWCI
- 16.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffraction-limited imaging in a scanning transmission x-ray microscope. https://app.cochat.ai/papers/10.1016/0030-4018(91)90016-7
- The paper
- Jacobsen, C., Williams, S., Anderson, E., Browne, M. T., Buckley, C. J., Kern, D., Kirz, J., Rivers, M., & Zhang, X. (1991). Diffraction-limited imaging in a scanning transmission x-ray microscope. Optics Communications. https://doi.org/10.1016/0030-4018(91)90016-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.