The design and calibration of a startle measurement system
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The present study sought to determine appropriate instrumentation for amplification and calibration of cages used to measure the acoustic startle response in rats. Fourier analysis indicated that the characteristic frequency of the rat startle response is about 5-15 Hz. This value was consistent in cages differing widely in resonant frequency, among several different transducers and across a range of large and small startle responses. Given this characteristic frequency range of startle, it is suggested that amplifiers fitted with band pass filters centered at about 10 Hz should be ideal for measuring startle while simultaneously excluding non-startle activity. A device is described which vibrates startle cages at 10 Hz, since this seems most appropriate for calibrating the sensitivity of a startle system. Data are presented showing that this type of calibrator is more valid than an impact-type calibrator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Conditioned fear as revealed by magnitude of startle response to an auditory stimulus.
Brown, J. S., Kalish, H. I., & Farber, I. E. (1951) · Journal of Experimental Psychology · doi:10.1037/h0060166 · Cited by 637
Strychnine: Brainstem and spinal mediation of excitatory effects on acoustic startle
Kehne, J. H., Gallager, D. W., & Davis, M. (1981) · European Journal of Pharmacology · doi:10.1016/0014-2999(81)90499-4 · Cited by 51
Self-citation
Cited by
Miserendino, M. J. D., Sananes, C. B., Melia, K. R., & Davis, M. (1990) · Nature · doi:10.1038/345716a0 · Cited by 824
Self-citationFear conditioning induces a lasting potentiation of synaptic currents in vitro
McKernan, M. G., & Shinnick-Gallagher, P. (1997) · Nature · doi:10.1038/37605 · Cited by 771
“Fear conditioning was measured using the potentiated startle paradig”
MethodExtinction of fear-potentiated startle: blockade by infusion of an NMDA antagonist into the amygdala
Falls, W., Miserendino, M., & Davis, M. (1992) · The Journal of Neuroscience · doi:10.1523/jneurosci.12-03-00854.1992 · Cited by 673
“The apparatus used to measure startle has been described in detail (Cassella and Davis, 1986).”
MethodSelf-citationWalker, D. L., & Davis, M. (1997) · The Journal of Neuroscience · doi:10.1523/jneurosci.17-23-09375.1997 · Cited by 627
“6 mA foot shock, measured using the method described by Cassella and Davis (1986), was used as the unconditioned stimulus.”
MethodResultSelf-citationCampeau, S., & Davis, M. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-03-02301.1995 · Cited by 479
Self-citation
Metadata
- Authors
- Cassella, J. V., & Davis, M.
- Venue
- Physiology & Behavior
- Publisher
- Elsevier BV
- Published
- 1986
- Volume
- 36
- Issue
- 2
- Pages
- 377-383
- ISSN
- 0031-9384 (ISSN-L)
- OpenAlex
- W2042902060
- Cited by
- 139
- References
- 2
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The design and calibration of a startle measurement system. https://app.cochat.ai/papers/10.1016/0031-9384(86)90032-6
- The paper
- Cassella, J. V., & Davis, M. (1986). The design and calibration of a startle measurement system. Physiology & Behavior. https://doi.org/10.1016/0031-9384(86)90032-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.