Topography of the foveal cone mosaic in the living human eye
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Interference fringes whose spatial frequency exceeds the resolution limit form visible moiré patterns with the foveal cone mosaic. This paper describes a model of foveal cone sampling that shows how these moiré patterns depend on the spatial frequency and orientation of an interference fringe imaged on a triangular lattice of cones. The model is tested with two psychophysical experiments. The first experiment shows that the behavior of the moiré patterns is quantitatively consistent with anatomical estimates of cone spacing across the human fovea. These patterns provide a psychophysical method for measuring cone spacing within 1.75 deg of the foveal center. In some observers, cone spacing is larger in a horizontal direction than in a vertical direction at any particular location within the fovea. The second experiment shows that the behavior of the moiré patterns is consistent with the triangular packing of foveal cones observed anatomically, and allows the orientation of the cone mosaic to be determined at the foveal center. These observations demonstrate the rich information that methods based on aliasing can provide about the topography of foveal cones in the living human eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Circular Statistics in Biology
Watson, G. S., & Batschelet, E. (1982) · Technometrics · doi:10.2307/1267831 · Cited by 4,587
Optical and retinal factors affecting visual resolution.
Campbell, F. W., & Green, D. G. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007784 · Cited by 1,595
Coxeter, H. S. M. (1969) · Cited by 1,582
Circular Statistics in Biology
Jupp, P. E., & Batschelet, E. (1982) · Biometrics · doi:10.2307/2530079 · Cited by 1,318
Topography of the Layer of Rods and Cones in the Human Retina
(1937) · Journal of the American Medical Association · doi:10.1001/jama.1937.02780030070033 · Cited by 817
Helmholtz's treatise on physiological optics
(1924) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(24)90484-4 · Cited by 696
Sampling and reconstruction of wave-number-limited functions in N-dimensional euclidean spaces
Petersen, D. P., & Middleton, D. (1962) · Information and Control · doi:10.1016/s0019-9958(62)90633-2 · Cited by 614
Distribution of Cones in Human and Monkey Retina: Individual Variability and Radial Asymmetry
Curcio, C. A., Sloan, K. R., Packer, O., Hendrickson, A. E., & Kalina, R. E. (1987) · Science · doi:10.1126/science.3576186 · Cited by 585 · cited 5×
“The psychophysical data show less variability between observers than the anatomical data of Curcio et al. (1987).”
BackgroundResultInfluentialThe Morphological Development of the Human Fovea
Hendrickson, A. E., & Yuodelis, C. (1984) · Ophthalmology · doi:10.1016/s0161-6420(84)34247-6 · Cited by 556 · cited 1×
“It is unclear whether the local anisotropy can be attributed to stresses on the adult fovea or to migrational forces responsible for the development of the fovea (Hendrickson and Yuodelis, 1984), which could be stronger in the vertical direction than horizontally.”
BackgroundPerry, V. H., & Cowey, A. (1985) · Vision Research · doi:10.1016/0042-6989(85)90004-5 · Cited by 494 · cited 3×
“(Perry and Cowey, 1985; de Monasterio et al., 1985; Hirsch and Miller, 1987). However, the fovea1 cone mosaic is extremely fragile, even in the hands of the most skilled anatomist, and it is difficult to be certain that measurements of the mosaic have not been distorted by shrinkage and other forms of histological art…”
BackgroundColour vision : physiology and psychophysics
Mollon, J. D., & Sharpe, L. T. (1983) · Academic Press eBooks · Cited by 456
The processing of hexagonally sampled two-dimensional signals
Mersereau, R. M. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11356 · Cited by 381 · cited 1×
“Results are the mean of from 3 to 8 observers, depending on retinal eccentricity, whose individual results are tabulated in Table I. Error bars represent & 1 SD based on variability between observers. The solid line represents data from &e&erg (1935) in the temporal retinal meridian and the dotted hne represents the m…”
BackgroundNon-linear projection of the retinal image in a wide-angle schematic eye.
Drasdo, N., & Fowler, C. W. (1974) · British Journal of Ophthalmology · doi:10.1136/bjo.58.8.709 · Cited by 301 · cited 1×
“Other representative values have been suggested such as about 0.27Smm/deg (Drasdo and Fowler, 1974).”
BackgroundAliasing in human foveal vision
Williams, D. R. (1985) · Vision Research · doi:10.1016/0042-6989(85)90113-0 · Cited by 277 · cited 15×
“This was achieved with the pulse overlap technique described by Williams (1985a).”
BackgroundMethodInfluentialSelf-citationRetinal limits to the detection and resolution of gratings
Thibos, L. N., Cheney, F. E., & Walsh, D. J. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001524 · Cited by 255
Identification of a subtype of cone photoreceptor, likely to be blue sensitive, in the human retina
Ahnelt, P. K., Kolb, H., & Pflug, R. (1987) · Journal of Comparative Neurology · doi:10.1002/cne.902550103 · Cited by 245 · cited 2×
“However, they are qualitatively consistent with the disorder seen in all anatomical specimens of the primate fovea (e.g. Borwein et ul., 1980; Hirsch and Hylton, 1984; Ahnelt et al., 1987; Hirsch and Miller, 1987).”
BackgroundCone spacing and the visual resolution limit
Williams, D. R., & Coletta, N. J. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001514 · Cited by 225
Self-citationSpectral analysis of spatial sampling by photoreceptors: Topological disorder prevents aliasing
Yellott, J. I. (1982) · Vision Research · doi:10.1016/0042-6989(82)90086-4 · Cited by 213 · cited 1×
“7 with a technique introduced by Yellott (1982).”
MethodDensity profile of blue-sensitive cones along the horizontal meridian of macaque retina.
de Monasterio, F. M., McCrane, E. P., Newlander, J. K., & Schein, S. (1985) · PubMed · Cited by 186
Helmholtz's Treatise on Physiological Optics
PEDDIE, W. (1925) · Nature · doi:10.1038/116088a0 · Cited by 178
Miller, W. H. (1979) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-66999-6_3 · Cited by 165 · cited 1×
“The psychophysical estimate of row spacing at the fovea1 center, 0.535 min of arc, is also in close agreement with the human anatomical estimate of Miller (1979), which was 0.536 min of arc.”
ResultInfluentialVisibility of interference fringes near the resolution limit
Williams, D. R. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001087 · Cited by 139
Self-citationPsychophysical estimate of extrafoveal cone spacing
Coletta, N. J., & Williams, D. R. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001503 · Cited by 115 · cited 2×
“…test this prediction because the local anisotropy is not very large at the fovea1 center for any of the observers for which the orientation of the lattice was measured. different psychophysical procedure IS requirecf to extract estimates of average cone spacing from it (Coletta and Williams, 1987).”
BackgroundSelf-citationHelmholtz's Treatise on Physiological Optics
Peddie, D. W. (1924) · Nature · doi:10.1038/114887a0 · Cited by 104
Does cone positional disorder limit resolution?
Hirsch, J., & Miller, W. H. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001481 · Cited by 99 · cited 4×
“However, recent measurements of cone spacing in the monkey (de Monasterio et al., 1985; Hirsch and Miller, 1987; and Ferry and Cowey, 1985) are also in good agreement with the psychophysical data though the angular cone spacing is somewhat larger in the monkey largely as a result of the smaller…”
BackgroundResultInfluentialConsequences of Spatial Sampling by a Human Photoreceptor Mosaic
Williams, D. R., & Collier, R. J. (1983) · Science · doi:10.1126/science.6867717 · Cited by 96
Self-citationBorwein, B., Borwein, D., Medeiros, J. A., & McGowan, J. W. (1980) · American Journal of Anatomy · doi:10.1002/aja.1001590202 · Cited by 95
Quality of the primate photoreceptor lattice and limits of spatial vision
Hirsch, J., & Hylton, R. (1984) · Vision Research · doi:10.1016/0042-6989(84)90060-9 · Cited by 83 · cited 2×
“However, they are qualitatively consistent with the disorder seen in all anatomical specimens of the primate fovea (e.g. Borwein et ul., 1980; Hirsch and Hylton, 1984; Ahnelt et al., 1987; Hirsch and Miller, 1987).”
BackgroundAveraging over the foveal receptor aperture curtails aliasing
Miller, W. H., & Bernard, G. D. (1983) · Vision Research · doi:10.1016/0042-6989(83)90147-5 · Cited by 78
Byram, G. M. (1944) · Journal of the Optical Society of America · doi:10.1364/josa.34.000718 · Cited by 63 · cited 1×
“Byram (1944) discovered that interference fringes could be detected in the fovea even when they were much finer than the resolution limit of about 60c/deg.* These high frequency interference fringes have a wavy, shimme~ng appearance that Byram suggested was a moir& pattern formed with the cone…”
BackgroundAliasing in the parafovea with incoherent light
Smith, R. A., & Cass, P. F. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.001530 · Cited by 59
Visual consequences of the foveal pit.
Williams, D. R. (1980) · PubMed · Cited by 49
Self-citationImaging system design for improved information capacity
Fales, C. L., Huck, F. O., & Samms, R. W. (1984) · Applied Optics · doi:10.1364/ao.23.000872 · Cited by 48
Cited by
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 3,167
Adaptive optics scanning laser ophthalmoscopy
Roorda, A., Romero-Borja, F., Donnelly III, W. J., Queener, H., Hebert, T. J., & Campbell, M. C. W. (2002) · Optics Express · doi:10.1364/oe.10.000405 · Cited by 967
Sequential ideal-observer analysis of visual discriminations.
Geisler, W. S. (1989) · Psychological Review · doi:10.1037//0033-295x.96.2.267 · Cited by 383
Organization of the human trichromatic cone mosaic
Hofer, H., Carroll, J., Neitz, J., Neitz, M., & Williams, D. R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2414-05.2005 · Cited by 364
Self-citationDigital Video Image Quality and Perceptual Coding
(2017) · CRC Press eBooks · doi:10.1201/9781420027822 · Cited by 317
Metadata
- Authors
- Williams, D. R.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1988
- Volume
- 28
- Issue
- 3
- Pages
- 433-454
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2002241514
- Cited by
- 159
- References
- 34
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.