The time course of adaptation to spatial contrast
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quest: A Bayesian adaptive psychometric method
Watson, A. B., & Pelli, D. G. (1983) · Perception & Psychophysics · doi:10.3758/bf03202828 · Cited by 2,410 · cited 2×
“5 dB by applying off-line the maximum-likelihood procedure (QUEST) developed by Watson and Pelli (1983). The method assumes that the psychometric function is well fitted by the following Weibull function:”
InfluentialBlakemore, C., & Campbell, F. W. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008862 · Cited by 2,030 · cited 6×
“The elevation in contrast threshold following adaptation has been shown to depend on the spatial frequency (Blakemore & Campbell, 1969; Pantle & Sekuler, 1968) and orientation (Blakemore & Nachmias, 1971) difference between the adapting and test gratings.”
InfluentialAn estimation and application of the human cortical magnification factor
Rovamo, J., & Virsu, V. (1979) · Experimental Brain Research · doi:10.1007/bf00236819 · Cited by 790
Contrast constancy: deblurring in human vision by spatial frequency channels.
Georgeson, M. A., & Sullivan, G. D. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011162 · Cited by 542 · cited 1×
“…in gain for low contrasts would serve to keep perceived contrast constant across the visual field despite variations in contrast thresholds (Georgeson & Sullivan, 1975). contrast gain control and neurai memory The present results are also of interest with respect to the functional role of…”
Self-citationContrast gain control in the cat's visual system
Ohzawa, I., Sclar, G., & Freeman, R. D. (1985) · Journal of Neurophysiology · doi:10.1152/jn.1985.54.3.651 · Cited by 522
Human cortical magnification factor and its relation to visual acuity
Cowey, A., & Rolls, E. T. (1974) · Experimental Brain Research · doi:10.1007/bf00237163 · Cited by 403
Size-Detecting Mechanisms in Human Vision
Pantle, A., & Sekuler, R. (1968) · Science · doi:10.1126/science.162.3858.1146-a · Cited by 317 · cited 2×
“Viewing of a high-contrast grating elevates contrast thresholds for subsequently detecting gratings of similar spatial frequency and orientation (Blakemore & Campbell, 1969; Pantle & Sekuler, 1968; Sekuler & Ganz, 1963).”
InfluentialThe orientation specificity of two visual after‐effects
Blakemore, C., & Nachmias, J. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009374 · Cited by 260 · cited 1×
“The elevation in contrast threshold following adaptation has been shown to depend on the spatial frequency (Blakemore & Campbell, 1969; Pantle & Sekuler, 1968) and orientation (Blakemore & Nachmias, 1971) difference between the adapting and test gratings.”
InfluentialContrast adaptation in striate cortex of macaque
Sclar, G., Lennie, P., & DePriest, D. D. (1989) · Vision Research · doi:10.1016/0042-6989(89)90087-4 · Cited by 249
Aftereffect of Seen Motion with a Stabilized Retinal Image
Sekuler, R. W., & Ganz, L. (1963) · Science · doi:10.1126/science.139.3553.419 · Cited by 191 · cited 1×
“Viewing of a high-contrast grating elevates contrast thresholds for subsequently detecting gratings of similar spatial frequency and orientation (Blakemore & Campbell, 1969; Pantle & Sekuler, 1968; Sekuler & Ganz, 1963).”
Cited by
Visual attention: The past 25 years
Carrasco, M. (2011) · Vision Research · doi:10.1016/j.visres.2011.04.012 · Cited by 2,483
Chung, S., Li, X., & Nelson, S. B. (2002) · Neuron · doi:10.1016/s0896-6273(02)00659-1 · Cited by 530
Fast and Slow Contrast Adaptation in Retinal Circuitry
Baccus, S. A., & Meister, M. (2002) · Neuron · doi:10.1016/s0896-6273(02)01050-4 · Cited by 515
“Slow adaptation did not (Blakemore and Campbell, 1969; Greenlee et al., 1991) affect kinetics, but produced a gradual hyperpolarizaand in cortical neurons (Ohzawa et al.”
Perceptual learning in Vision Research
Sagi, D. (2011) · Vision Research · doi:10.1016/j.visres.2010.10.019 · Cited by 438
Anstis, S., Verstraten, F. A. J., & Mather, G. (1998) · Trends in Cognitive Sciences · doi:10.1016/s1364-6613(98)01142-5 · Cited by 407
Webster, M. A. (2015) · Annual Review of Vision Science · doi:10.1146/annurev-vision-082114-035509 · Cited by 334
Visual adaptation and face perception
Webster, M. A., & MacLeod, D. I. A. (2011) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2010.0360 · Cited by 325
Adaptation to Temporal Contrast in Primate and Salamander Retina
Chander, D., & Chichilnisky, E. J. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-24-09904.2001 · Cited by 238
“Slow-onset adaptation observed in psychophysical experiments (Blakemore and Campbell, 1969; Lorenceau, 1987; Schieting and Spillmann, 1987; Greenlee et al., 1991; Hammett et al., 1994) and in cortical neurons (Movshon and Lennie, 1979; Albrecht et al.”
BackgroundSpatial frequency adaptation and contrast gain control
Wilson, H. R., & Humanski, R. (1993) · Vision Research · doi:10.1016/0042-6989(93)90248-u · Cited by 209
Contrast Adaptation and Representation in Human Early Visual Cortex
Gardner, J. L., Sun, P., Waggoner, R. A., Ueno, K., Tanaka, K., & Cheng, K. (2005) · Neuron · doi:10.1016/j.neuron.2005.07.016 · Cited by 202
“Fi- f (nally, the contrast gain changes that we have documented are closely paralleled by psychophysical mea- n csurements (Greenlee et al., 1991; Greenlee and Heitger, 1988).”
BackgroundOrientation-Tuned fMRI Adaptation in Human Visual Cortex
Fang, F., Murray, S. O., Kersten, D., & He, S. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00378.2005 · Cited by 186
Contrast adaptation and contrast masking in human vision
(1991) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.1991.0125 · Cited by 176
Orientation-Specific Adaptation in Human Visual Cortex
Boynton, G. M., & Finney, E. M. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-25-08781.2003 · Cited by 168
“For matching adapters and targets, detection thresholds recover as an exponential function over time (Greenlee et al., 1991).”
Background
Metadata
- Authors
- Greenlee, M. W., Georgeson, M. A., Magnussen, S., & Harris, J. P.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 1991-01
- Volume
- 31
- Issue
- 2
- Pages
- 223-236
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2110595125
- Cited by
- 170
- References
- 19
- FWCI
- 3.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.