[6] Correction for liquid junction potentials in patch clamp experiments
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This chapter describes corrections that have to be applied to measured membrane potentials in patch clamp experiments. Some of them [Eqs. (1)-(3)] are required regardless of the nature of the reference electrode (in the Ringer's solution bath) whenever the pipette-filling solution is different from the bath solution. They represent the liquid junction potentials that are present at the pipette tip before patch formation. In addition, corrections have to be applied when the bath solution is being changed during a measurement (i.e., after seal formation). In that case the following rules apply. (1) The new solution should never get into contact with the bare silver/silver chloride wire of the reference electrode. This requirement is best met by using a salt bridge. (2) The "best" salt bridge is a 3 M KCl bridge with an abrupt KCl-bath fluid boundary at its tip (see above). This bridge does not require any additional potential corrections, but it may lead to KCl poisoning of the bath or become contaminated by solutions used previously. (3) Local solution changes (microperfusion by puffer pipette, U tool or sewer pipe arrangements) as well as recessed KCl bridges require additional corrections, which (together with the simple liquid junction potential correction) are approximately given by Eqs. (6)-(8). It should be stressed that all equations given here represent approximate corrections, since liquid junction potentials are thermodynamically ill-defined. This is particularly relevant for Eqs. (6) and (7) where the sum of two liquid junction potentials appears.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Automated reconstructions were then extensively manually corrected and curated using a range of tools (e.g., virtual finger, polyline) in the Mozak extension (Zoran Popovic, Center for Game Science, University of Washington) of Terafly tools50,53 in Vaa3D.”
From Classification of electrophysiological and morphological neuron types in the mouse visual cortex (2019) · cites this paper as [50]
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Self-citationAshcroft, F. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90114-3 · Cited by 982
A patch-clamp study of bovine chromaffin cells and of their sensitivity to acetylcholine
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014393 · Cited by 812
Self-citationRates of diffusional exchange between small cells and a measuring patch pipette
Pusch, M., & Neher, E. (1988) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00582316 · Cited by 703
Self-citationLiquid junction potentials and small cell effects in patch-clamp analysis
Barry, P. H., & Lynch, J. W. (1991) · The Journal of Membrane Biology · doi:10.1007/bf01870526 · Cited by 672
Barry, P. H., & Diamond, J. M. (1970) · The Journal of Membrane Biology · doi:10.1007/bf01868010 · Cited by 201
Research works printed but not linked: 2
- P. H. Barry, this series, Vol. 171, p. 678.
- Bockris, 1970, Vol. 1.
Cited by
Smith, R. R., Barile, L., Cho, H. C., Leppo, M. K., Hare, J. M., Messina, E., Giacomello, A., Abraham, M. R., & Marbán, E. (2007) · Circulation · doi:10.1161/circulationaha.106.655209 · Cited by 1,140
Winslow, R. L., Rice, J., Jafri, S., Marbán, E., & O’Rourke, B. (1999) · Circulation Research · doi:10.1161/01.res.84.5.571 · Cited by 797
Owens, D. F., Boyce, L. H., Davis, M. B. E., & Kriegstein, A. R. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-20-06414.1996 · Cited by 721
“Liquid junction potentials for the CsCl and KCl filling solutions (Neher, 1992) were24.”
BackgroundBarry, P. H. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90031-0 · Cited by 602
Santoro, B., Chen, S., Lüthi, A., Pavlidis, P., Shumyatsky, G. P., Tibbs, G. R., & Siegelbaum, S. A. (2000) · The Journal of Neuroscience · doi:10.1523/jneurosci.20-14-05264.2000 · Cited by 600
“A liquid junction potential of 7–8 mV measured as described (Neher, 1992) was taken into account for all the data.”
Method
Metadata
- Authors
- Neher, E.
- Affiliations
- Max Planck Society (DE)
- Corresponding author
- Neher, Erwin
- ORCID
- Neher, Erwin
- Venue
- Methods in Enzymology
- Publisher
- Elsevier
- Published
- 1992
- Volume
- 207
- Pages
- 123-131
- ISSN
- 0076-6879 (ISSN-L)
- OpenAlex
- W1561818412
- Cited by
- 1,132
- References
- 6
- Citations by year
- 2026: 14 · 2025: 17 · 2024: 11 · 2023: 13 · 2022: 19 · 2021: 19 · 2020: 35 · 2019: 26 · 2018: 25 · 2017: 21 · 2016: 24 · 2015: 29 · 2014: 25 · 2013: 31 · 2012: 28
- FWCI
- 27.85
- Type
- book chapter
- Language
- en
- Open access
- closed
- Locations
- Methods in enzymology on CD-ROM/Methods in enzymology (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- liquid junction potential, patch clamp, reference electrode, Ag/AgCl electrodes, salt bridges, microperfusion
- MeSH terms
- Amplifiers, Electronic, Electrophysiology, Membrane Potentials, Microelectrodes, Potentiometry, Solutions, Artifacts
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.