Optimal defrost cycle for the air cooler
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
There must be an optimal time between two consecutive defrost operations.
“since Zakrzewski [20] pointed out that there must be an optimal time between two consecutive defrost operations.”
From Optimal design of fan-supplied tube-fin evaporators subjected to frosting conditions aiming at minimum energy consumption (2018) · cites this paper as [20]
Zakrzewski's correlation underestimates the optimum runtime and overestimates the cooling cycle efficiency compared with the new defrost efficiency correlation.
“One can see that the later underestimates the optimum runtime and overestimate the cooling cycle efficiency as it provides higher figures for the defrost efficiency in the range of mass-to-surface area under analysis”
From Optimal defrost cycle for air coolers revisited: A study of fan-supplied tube-fin evaporators (2018) · cites this paper as Zakrzewski (1984)
Cited by
Sorted by citations
A novel hybrid frost detection and defrosting system for domestic refrigerators
Malik, A. N., Khan, S. A., & Lazoglu, I. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2020.05.016 · Cited by 44 · see citing works
Optimal defrost cycle for air coolers revisited: A study of fan-supplied tube-fin evaporators
da Silva, D. L., & Hermes, C. J. L. (2018) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2018.02.009 · Cited by 22 · see citing works
Ribeiro, R. S., da Silva, D. L., & Hermes, C. J. L. (2018) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-018-1401-4 · Cited by 1 · see citing works
- Authors
- Zakrzewski, B.
- Affiliations
- University of Szczecin (PL)
- Corresponding author
- Zakrzewski, B
- ORCID
- Zakrzewski, B
- Venue
- International Journal of Refrigeration
- Publisher
- Elsevier BV
- Published
- 1984-01
- Volume
- 7
- Issue
- 1
- Pages
- 41-45
- ISSN
- 0140-7007 (ISSN-L)
- OpenAlex
- W2162963662
- Cited by
- 20
- References
- 0
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 2 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 2 · 2016: 1 · 2015: 1
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Refrigeration (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Keywords
- air coolers, frost accumulation, frost density, heat transfer coefficient, cooling capacity, computer simulation model, refrigeration performance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review