  • With an increase of 53% in air velocity, the frost mass accumulated increased by 28% under Kondepudi and O'Neal (1989) conditions.

    “With an increase of 53 % in air velocity, the frost mass accumulated increased by 28 %.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Kondepudi and O'Neal (1989)

  • Higher air velocity leads to a higher heat and mass transfer coefficient, thereby increasing the amount of moisture converted to frost in the same time period.

    “They explained that higher air velocity leads to a higher heat and mass transfer coefficient, thereby increasing the amount of moisture being converted to frost in the same time period.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Kondepudi and O'Neal (1989)

  • As air velocity increases, the frosting rate increases.

    “For the effect of air velocity on frosting rate, Gatchilov and Ivanova (1979), Kondepudi and O'Neal (1989) and Rite and Crawford (1991) agreed that as the air velocity increases, the frosting rate increases.”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Kondepudi and O'Neal (1989)

  • Kondepudi and O'Neal (1989) proposed that the energy transfer coefficient E_o can be expressed by equation (4.4).

    “Kondepudi and O'Neal (1989) in their paper proposed that the energy transfer coefficient, E o , can be expressed as follow: p,a o Q.C E LMED.A = (4.4)”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Kondepudi and O'Neal (1989)

  • The decreasing trend agrees with results reported by Kondepudi and O'Neal (1989) and Ameen (1993).

    “This decreasing trend agrees with all the results reported by researchers such as Kondepudi and O'Neal (1989) and Ameen (1993).”

    From Studies of an air cooler under frost condition (2019) · cites this paper as Kondepudi and O'Neal (1989)

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 5 · Cited by 67

Authors
Kondepudi, S. N., & O'Neal, D. L.
Affiliations
Texas A&M University (US)
Venue
International Journal of Refrigeration
Publisher
Elsevier BV
Published
1989-05
Volume
12
Issue
3
Pages
151-158
ISSN
0140-7007 (ISSN-L)
OpenAlex
W2084665646
Cited by
67
References
5
Citations by year
2026: 2 · 2025: 3 · 2023: 3 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 5 · 2015: 3 · 2014: 4 · 2013: 3 · 2012: 7
FWCI
3.79
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Refrigeration (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
Keywords
frost growth, air-to-air heat exchanger, pressure drop, energy transfer coefficient, air humidity, fin spacing, frost accumulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review