Cited by 30Icing and De-icing TechnologiesHeat Transfer and OptimizationHeat Transfer Mechanisms

Frost formation and heat transfer on circular cylinders in cross-flow

Raju, S.P, Sherif, S.A·1993·International Journal of Refrigeration

Integrity signals

Registry

Crossref · 10.1016/0140-7007(93)90056-e

Cites

0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Frost formation on flat plate and cylindrical surfaces is relatively well known and can be predicted reliably with existing models and correlations.

    “Therefore, frost formation on flat plate and cylindrical surface is relatively well known and can be predicted reliably with existing models and correlations.”
  • The frost density correlations proposed in previous studies do not consider the temperature and humidity variation of the moist air in the flow direction.

    “Unfortunately, the frost density correlations proposed in the previous studies do not consider the temperature and humidity variation of the moist air in the flow direction.”
  • Frost thickness at the separation point of a cylinder under cross flow increases with increasing air moisture content, but decreases with increasing cylinder surface temperature and air velocity.

    “The authors concluded that frost thickness at the separation point was increased with an in­ crease in air moisture content, but decreased with an increase in cylinder surface temperature and air velocity.”
  • Frost accumulated on a cylinder under cross flow condition is not uniform due to air flow separation.

    “Generally, frost accumulated on a cylinder under cross flow con­ dition was not uniform due to air flow separation.”
  • Frost thickness at the windward stagnation point of a cylinder under cross flow is greater than at the separation point (angle ~82°).

    “Raju and Sherif [123] pointed out that frost thickness at the windward stagnation point was greater than that at the separation point (the angle between which and the inverse direction of air flow was around 82 ◦ ).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Raju, S. P., & Sherif, S. A.
Affiliations
  • University of Washington (US)
  • University of Florida (US)
Venue
International Journal of Refrigeration
Publisher
Elsevier BV
Published
1993-01
Volume
16
Issue
6
Pages
390-402
ISSN
0140-7007 (ISSN-L)
OpenAlex
W2094507337
Cited by
30
References
0
Citations by year
2026: 1 · 2025: 1 · 2022: 1 · 2021: 1 · 2017: 2 · 2015: 1 · 2014: 2 · 2013: 1 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
closed
Locations
International Journal of Refrigeration (publishedVersion)
Funders
  • University of Miami
  • University of Florida
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer Mechanisms
Keywords
frost formation, heat transfer, circular cylinder, crossflow, humid air, transient modeling, boundary layer equations, frost density, dew point

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›