Performance of tuned mass dampers under wind loads
The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
BISHOP, R. E. D. (1957) · Nature · doi:10.1038/179504a0 · Cited by 1,636
Random Vibration in Mechanical Systems
(1963) · Elsevier eBooks · doi:10.1016/c2013-0-12506-8 · Cited by 899
Control of Along‐Wind Response of Structures by Mass and Liquid Dampers
Xu, Y. L., Samali, B., & Kwok, K. C. S. (1992) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1992)118:1(20 · Cited by 189
Self-citationXu, Y. L., Kwok, K. C. S., & Samali, B. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90519-g · Cited by 70
Self-citationControl of wind-induced tall building vibration by tuned mass dampers
Xu, Y. L., Kwok, K. C. S., & Samali, B. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90518-f · Cited by 66
Self-citationWind response of a tower (Typhoon observation at the Nagasaki Huis Ten Bosch Domtoren)
Tamura, Y., Shimada, K., & Kazuki, H. I. B. I. (1993) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(93)90086-4 · Cited by 62
Full-scale measurements of wind-induced acceleration response of Sydney Tower
Kwok, K. C. S., & Macdonald, P. A. (1990) · Engineering Structures · doi:10.1016/0141-0296(90)90002-a · Cited by 53
Self-citationEffect of tuned mass dampers on wind induced response of tall buildings
Tanaka, H., & MAK, C. Y. (1983) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(83)90037-5 · Cited by 41
Tuned active dampers installed in the Minato Mirai (MM) 21 landmark tower in Yokohama
Yamazaki, S., Nagata, N., & Abiru, H. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90618-k · Cited by 34
Time history response of a tall building with a tuned mass damper under wind force
Kawaguchi, A., Teramura, A., & Omote, Y. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90619-l · Cited by 33
Research works printed but not linked: 7
- 1994, Putting a damper on swaying building, The Sydney Morning Herald, 6
- Konno, 1989, Examples of practical applications of dampers, (4) Higashiyama Sky Tower, Struct.
- 1975, Hancock Tower to get dampers, Engineering News Record, 11
- Kitamura, 1988, Chiba Port Tower: full-scale measurement of wind actions (Part 1) Organisation, measurement system and strong wind data, J. Wind Engng, 37, 401
- Ibe, 1988, Fukuoka Tower project, Build. Lett.
- Kihara, 1989, Examples of practicable applications of dampers, (1) Fukuoka Tower, Struct.
- Yamashita, 1992, Wind resistant design of a tall building — damping systems for ACT Tower, Think 33, 10, 24
Cited by
Items 101–200 of 238
A Ball-Track-NES for the vibration control of flexible structures under seismic excitation
Miguel, L. F. F. (2024) · Soil Dynamics and Earthquake Engineering · doi:10.1016/j.soildyn.2024.108825 · Cited by 14
Başaran, S., Bolat, F. Ç., & Sivrioğlu, S. (2021) · Journal of Vibration and Control · doi:10.1177/1077546321998878 · Cited by 14
“In the literature, this system is referred to as tuned mass dampers (TMDs) (Elias et al., 2019; Lackner and Rotea, 2010; Kwok and Samali, 1995; Martynowicz, 2019; Miyata, 2003; Tian et al., 2019).”
BackgroundAnalysis of random wind-induced response of isolation structure with viscoelastic damper and TMD
Ma, J., Zou, W., & Bai, G. (2022) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2022.105178 · Cited by 14
Control on Dynamic Structural Response Using Active-Passive Composite-Tuned Mass Dampers
Wang, C. M., Yan, N., & Balendra, T. (1999) · Journal of Vibration and Control · doi:10.1177/107754639900500308 · Cited by 14
Control of the Wind Induced Response of Structures
Kareem, A., Bernardini, E., & Spence, S. M. J. (2013) · Springer eBooks · doi:10.1007/978-4-431-54337-4_14 · Cited by 13
Kim, J., Park, C.-S., & Min, K.-W. (2016) · Measurement · doi:10.1016/j.measurement.2016.04.030 · Cited by 13
Vibration Control of Marine Top Tensioned Riser with a Single Tuned Mass Damper
Song, J., Wang, T., Chen, W., Guo, S., & Yan, D. (2020) · Journal of Marine Science and Engineering · doi:10.3390/jmse8100785 · Cited by 12
“TMDs are widely used in the field of civil engineering, such as in truss bridges [2], high-rise buildings [3], high towers [4], and structures.”
BackgroundOutput-only de-tuning assessment of tuned mass dampers
Hazra, B., & Sadhu, A. (2012) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-012-0031-2 · Cited by 12
On the cybersecurity of smart structures under wind
Montoya, M. C., Rubio-Medrano, C. E., & Kareem, A. (2024) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2024.105777 · Cited by 10
Cui, W., Ma, T., & Caracoglia, L. (2020) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/j.jweia.2020.104394 · Cited by 10
“For super-tall buildings, installation of a tuned mass damper (TMD) is considered to suppress wind-induced vibration and improve structural performance (Kwok and Samali, 1995; Elias and Matsagar, 2017, 2018).”
BackgroundWani, Z. R., Tantray, M., & Sheikh, J. I. (2021) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1884 · Cited by 10
Acceleration‐based effective damping ratio of tuned mass damper under seismic excitations
He, H., Tan, P., & Hao, L. (2021) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1910 · Cited by 10
Broadband damping of high-precision motion stages
Verbaan, C. K., van der Meulen, S., & Steinbuch, M. (2016) · Mechatronics · doi:10.1016/j.mechatronics.2016.10.014 · Cited by 10
Bi‐tuned semi‐active TMDs: Multi‐hazard design for tall buildings using gradient‐based optimization
Kleingesinds, S., & Lavan, O. (2021) · Structural Control and Health Monitoring · doi:10.1002/stc.2901 · Cited by 10
“TMDs were initially used to control wind effects, usually as a single element installed at the top of the building.(12,13) In such cases, the design was commonly based on the classic Den Hartog theory(14) and following works considering distinct load cases.”
MethodRahman, S., Jain, A. K., Jha, K. N., Bharti, S. D., & DATTA, T. K. (2024) · Structures · doi:10.1016/j.istruc.2024.107526 · Cited by 9
Ghaderi, P., & Farsijani, D. (2024) · Journal of Earthquake Engineering · doi:10.1080/13632469.2024.2436109 · Cited by 10
“…control devices which effectiveness in reducing structural vibrations such as earthquake excitations (Chang, Shia, and Lai 2018; Elias and Matsagar 2017; Ghaderi and Gholam 2023; L. Wang et al. 2023) and wind loads (Elias and Matsagar 2018; Kwok and Samali 1995; Liu et al. 2008) has been proven.”
Ten questions concerning wind-focused shape and structural optimization of tall buildings
Alanani, M., Elshaer, A., Vasilopoulos, S., Spence, S. M. J., Bitsuamlak, G., & Damatty, A. E. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113716 · Cited by 9
A Study on Effect of Water Tanks Modeled As Tuned Mass Dampers on Dynamic Properties of Structures
Kumar, D. R., Naik, M. G. V., & Hoseinzadeh, F. (2015) · doi:10.1061/9780784479070.009 · Cited by 8
“Kwok and Samali (1995) discussed the performance of TMDs under wind loads.”
BackgroundCao, Z., Hua, X., Wen, Q., Chen, Z., & Niu, H. (2019) · Advances in Structural Engineering · doi:10.1177/1369433219829807 · Cited by 8
“TMDs have been widely applied in civil engineering structures such as high-rise buildings (Irwin, 2009; Kareem and Kijewski, 1999; Kwok and Samali, 1995; Shi et al., 2012; Wang et al., 2018; Xu et al., 2017), long-span bridges (Battista and Pfeil, 2000; Fujino and Yoshida, 2002; Larsen et al.”
Bagheri, S., & Rahmani-Dabbagh, V. (2020) · Journal of Vibration and Control · doi:10.1177/1077546320951329 · Cited by 8
“…to various loads such as harmonic or white noise (Bakre and Jangid, 2007; Den Hartog, 1956; Tsai and Lin, 1993; Warburton, 1982), wind (Aly, 2014; Chung et al., 2013; Kwok and Samali, 1995), and seismic excitations (Greco and Marano, 2013; Miranda, 2012; Mrabet et al., 2018; Sadek et al., 1997).”
BackgroundAgwoko, M. P., Chen, Z., & Liu, H. (2020) · International Journal of Steel Structures · doi:10.1007/s13296-020-00438-x · Cited by 8
Optimization and performance evaluation of nonlinear pendulum tuned mass damper inerters (NPTMDIs)
Ma, R., Yang, X., Song, J. G., Bi, K., & Du, X. (2025) · Journal of Building Engineering · doi:10.1016/j.jobe.2025.113157 · Cited by 7
Reduction of wind-induced vibration of a laminated plate with an active constrained layer
Li, J., & NARITA, Y. (2013) · Journal of Vibration and Control · doi:10.1177/1077546312472922 · Cited by 7
“Using passive and active tuned mass damper systems, Kwok and Samali (1995) studied the suppression of dynamic response in tall buildings and other structures against wind pressure.”
BackgroundCOMPARISONS OF A TALL BUILDING WIND RESPONSE WITH AND WITHOUT A TMD
de Barros, R. C., Delgado, R. M., & Frías, R. (2011) · Cited by 7
Experimental Studies on an Adaptive Tuned Mass Damper with Real-Time Tuning Capability
Roffel, A. J., Lourenco, R., & Narasimhan, S. (2010) · ASCE Structures Congress · doi:10.1061/41131(370)27 · Cited by 7
Pani, S., Senapati, S., Patra, K. C., & Nath, P. (2017) · International Journal of Engineering Research and Applications · doi:10.9790/9622-0707034977 · Cited by 7
Assessment and Mitigation of Wind Risk of Suspended-Span Bridges
Salvatori, L. (2007) · Florence Research (University of Florence) · doi:10.24355/dbbs.084-200805160200-8 · Cited by 6
Seismic reduction principle and response analysis of variable damping viscous damper system
Liang, S., Zhang, Z., & Li, A. (2023) · International Journal of Structural Integrity · doi:10.1108/ijsi-08-2023-0085 · Cited by 5
Optimization of Viscoelastic Tuned Mass Damper Systems Subjected to Coloured Excitations
Argenziano, M., Palmeri, A., Carotenuto, A. R., Mele, E., & Fraldi, M. (2025) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.70025 · Cited by 5
“Indeed, the role of viscoelasticity in structural dynamics and the effectiveness of dynamic vibration absorbers extend across civil, mechanical and biomedical engineering [22–30].”
Dynamic characterization of fractional oscillators for Fractional Tuned Mass Dampers tuning
Barone, G., Iacono, F. L., & Navarra, G. (2014) · International Conference on Fractional Differentiation and Its Applications (ICFDA) · doi:10.1109/icfda.2014.6967371 · Cited by 5
Analytical Analysis for Parameter Design of Attached Nonlinear Energy Sink
Zhang, T., Li, L., & Zheng, Y. (2021) · Shock and Vibration · doi:10.1155/2021/5163479 · Cited by 5
“, the John Hancock Tower in Boston, Citicorp Center office building in New York, and Chiba Port Tower in Japan [1].”
BackgroundVibration Control of Large Wind Turbine Blades with Unidirectional Cable Pendulum Damper
Li, W., Qiao, L., Li, G., & Du, Y. (2022) · International Journal of Structural Stability and Dynamics · doi:10.1142/s0219455423500827 · Cited by 5
Super-long-span bridges: wind-resistant design developments and open issues
Spinelli, P., Marra, A. M., & Salvatori, L. (2023) · Proceedings of the Institution of Civil Engineers - Bridge Engineering · doi:10.1680/jbren.23.00020 · Cited by 5
EFFECTIVENESS OF TUNED MASS DAMPER IN DAMAGE REDUCTION OF BUILDING UNDER FAR-FIELD GROUND MOTIONS
Ngamkhanong, C., & Pinkaew, T. (2015) · COMPDYN Proceedings · doi:10.7712/120115.3444.878 · Cited by 5
“Tuned mass dampers, consist of stiffness, inertia and damping elements, has been used for vibration control of structures under lateral load such as wind [1,2] and earthquake.”
Vibration control of an irregular structure using single and multiple tuned mass dampers
Khan, I. U., Usman, M., & Tanveer, M. (2021) · Proceedings of the Institution of Civil Engineers - Structures and Buildings · doi:10.1680/jstbu.21.00011 · Cited by 5
Dyk, C. V. (2008) · SUNScholar (Stellenbosch University) · Cited by 5
On aspects of boundary damping for cables and vertical beams
Hijmissen, J. W. (2008) · Research Repository (Delft University of Technology) · Cited by 5
Efeito do vento em edifícios altos : aplicação a um caso concreto
Ferreira, N. A. C. (2008) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/9epf-dx39 · Cited by 5
Robust mass damper design for bandwidth increase of motion stages
Verbaan, C. K. (2015) · TU/e Research Portal · doi:10.6100/ir791842 · Cited by 5
Most, T., Zabel, V., Das, R. R., & Khadka, A. (2025) · Applied Sciences · doi:10.3390/app15179329 · Cited by 4
Liu, J., Liu, C., Ke, Y., Chen, W., Shum, K. M., Tse, K. T., & Hu, G. (2025) · Physics of Fluids · doi:10.1063/5.0298947 · Cited by 4
Gasparetto, V. E. L., Reid, J., & ElSayed, M. S. A. (2023) · Applied Mechanics · doi:10.3390/applmech4030042 · Cited by 4
A STUDY ON EFFECT OF WATER TANKS MODELED AS TUNED MASS DAMPERS ON DYNAMIC PROPERTIES OF STRUCTURES
Kumar, D. R. (2015) · International Journal of Research in Engineering and Technology · doi:10.15623/ijret.2015.0425072 · Cited by 4
Shin, Y., & Kim, J. (2021) · Sensors · doi:10.3390/s21248211 · Cited by 4
Semi-active control of mid-story isolation building system
Chey, M., Chase, J. G., Mander, J. B., & Carr, A. J. (2009) · UC Research Repository (University of Canterbury) · Cited by 4
Optimization of pendulum tuned mass damper in tall building under horizontal earthquake excitation
Hassani, S., & Aminafshar, M. (2016) · Bulletin de la Société Royale des Sciences de Liège · doi:10.25518/0037-9565.5455 · Cited by 4
“In the Chifley tower, using this technic, frequency of the pendulum is changed simply by some equipment applied near the pendulum’s support (Kwok and Samali, 1995) [11].”
MethodAnálisis de un amortiguador de masa sintonizado óptimo en estructuras asimétricas no lineales
Espinoza, G., Neira, D., & Cifuentes, A. (2018) · Obras y proyectos · doi:10.4067/s0718-28132018000100039 · Cited by 4
Yu, W., & Thenozhi, S. (2015) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-319-28025-7_2 · Cited by 4
Qiao, H., Liu, J., Wang, Q., Zhang, Z., Zhao, W., & Huang, P. (2025) · Engineering Structures · doi:10.1016/j.engstruct.2025.121979 · Cited by 3
Multiple-TMD-Based Structural Vibration Control for Pumped Storage Power Plants
Zhong, T., Feng, X., Zhang, Y., & Zhou, J. (2020) · Applied Sciences · doi:10.3390/app10165577 · Cited by 3
“The effective use of TMDs for vibration response control of structures subjected to earthquake and wind excitations was shown by Kwok and Samali [20] and Pinkaew et al. [21].”
MethodMultihazard Optimization-Based Simultaneous Design of Multistory Concrete Structures and TMDs
Kleingesinds, S., & Lavan, O. (2024) · Journal of Structural Engineering · doi:10.1061/jsendh.steng-13139 · Cited by 3
Parameter optimization of multi-TMDS for windexcited vibration suppression of tall buildings
Zheng, G., Ni, Y. Q., Li, H., & Duan, Y. (2002) · Elsevier eBooks · doi:10.1016/b978-008044100-9/50129-7 · Cited by 3
Cross-wind excitation of a 2D square prism with vibrating leading edge flaps
Li, Y. F., Flay, R. G. J., & Richards, P. J. (2002) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/s0167-6105(02)00344-6 · Cited by 3
Kawecki, J., & Masłowski, R. (2010) · Repozytorium Politechniki Krakowskiej · Cited by 3
Pendulum TMD’s in Building Vibration Control
de Barros, R. C., & Sousa, C. M. A. E. (2016) · Lecture notes in electrical engineering · doi:10.1007/978-3-319-43671-5_47 · Cited by 3
Ávila, S. M., & Gonçalves, P. B. (2010) · Mecánica Computacional (Asociación Argentina de Mecánica Computacional) · Cited by 3
Kheirkhah, S., Lourenco, R., Yarusevych, S. V., & Narasimhan, S. (2013) · Journal of Fluids Engineering · doi:10.1115/1.4025059 · Cited by 3
Experimental Analysis of a Tuned Mass Damper with Eddy Currents Damping Effect
Feudo, S. L., Allani, A., Cumunel, G., Argoul, P., Maceri, F., & Bruno, D. (2017) · Springer series in solid and structural mechanics · doi:10.1007/978-3-319-48884-4_13 · Cited by 3
Guntur, H. L., Daman, A. A. A., & Hendrowati, W. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/588/1/012029 · Cited by 3
“Furthermore, the Tuned Mass Damper (TMD) is developed to reduce the vibration of structure [2,3].”
Hazra, B. (2010) · UWSpace (University of Waterloo) · Cited by 3
Amortecedor tipo pêndulo invertido para controle de vibrações em edifícios altos
Júnior, P. L. B. (2018) · RIUnB Institutional Repository (University of Brasília) · doi:10.26512/2018.08.d.34432 · Cited by 3
Application d’un Système (TMD) pour l’Amélioration de la Réponse Sismique des Structures Bâtiments
Mahi, M. H., & Bouali, A. (2012) · Dépôt Institutionnel de lUniversité de Tlemcen · Cited by 3
The Effects of Viscoelastic Behavior on the Operation of a Delayed Resonator Vibration Absorber
Cowans, J. Q. (2006) · TigerPrints (Clemson University) · Cited by 3
Liu, J., Hu, Y., Yao, J., & Zhang, Q. (2023) · Buildings · doi:10.3390/buildings13112866 · Cited by 2
An innovative design method for nonlinear tuned mass damper
Li, L., & Du, Y. (2018) · Structural Monitoring and Maintenance · doi:10.12989/smm.2018.5.2.261 · Cited by 2
“Up to now, the working principle of TMD has been basically improved (Den Hartog 1947, Yao 1972, Warburton 1982, Tsai and Lin 1993, Zuo and Nayfeh 2004, Kareem and Kline 1995, Wu and Chen 2000, Kwok and Samali 1995).”
BackgroundAnalysis and active control for wind induced vibration of beam with ACLD patch
Li, J., & NARITA, Y. (2013) · Wind and Structures · doi:10.12989/was.2013.17.4.399 · Cited by 2
Active control of vibrations of a tall structure excited by external forces
Jamil, M., Sharkh, S. M., Javid, M. N., & Nagendra, V. (2009) · ePrints Soton (University of Southampton) · Cited by 2
Kim, J., Jang, S.-J., & Min, K.-W. (2016) · Journal of Sensors · doi:10.1155/2016/6874125 · Cited by 2
Effect of using linear multiple tuned mass dampers on concrete structures with hysteresis behavior
Shooshtari, M., & Mortezaie, H. (2017) · Journal of Vibroengineering · doi:10.21595/jve.2016.17487 · Cited by 2
“Although TMD performance under basic harmonic excitation and the wind load is determined [9, 10], with further investigation on poor performance of TMD became apparent under earthquake load and it was found that the efficiency of TMD can change under different earthquake records, structural characteristics and soil co…”
BackgroundArtificial Intelligence Approach for Seismic Control of Structures
Radmard Rahmani, H. (2020) · Publication Server of Weimar Bauhaus-University (Weimar Bauhaus-University) · doi:10.25643/bauhaus-universitaet.4135 · Cited by 2
Yang, F. (2008) · Spectrum Research Repository (Concordia University) · Cited by 2
Seismic response of building equipped with an FPS-TMD featuring restraining rim
Li, Z., Xu, Z., Huang, G., Fu, J., & Wu, J. (2026) · Engineering Structures · doi:10.1016/j.engstruct.2026.122093 · Cited by 1
Lee, S. (2007) · Journal of the Earthquake Engineering Society of Korea · doi:10.5000/eesk.2007.11.2.047 · Cited by 1
Active Control of Wind-Induced Building Vibration Using a Linear Coupling Strategy
Hashemi, S. M., & Golnaraghi, M. F. (2001) · ASME Biennial Conference on Mechanical Vibration and Noise · doi:10.1115/detc2001/vib-21418 · Cited by 1
“1 There have been numerous investigations, both analytical/numerical and experimental, into the area of passive vibration control of tall buildings [2-21].”
BackgroundInfluentialANALYSIS OF ENERGY ABSORBING DEVICE BASED ON DAMPED DYNAMIC VIBRATION ABSORBER
Zheng, Z., Yao, T., Huang, P., & Chang, Z. (2016) · Transactions of the Canadian Society for Mechanical Engineering · doi:10.1139/tcsme-2016-0034 · Cited by 1
Monitoringgestützte Analyse von Schwingungsdämpfern in Turmbauwerken
Dragos, K., Steiner, M., Zabel, V., & Smarsly, K. (2018) · Bautechnik · doi:10.1002/bate.201700083 · Cited by 1
Aerodynamic Behavior and Stability of the Tall and Slender Brasilia Telecom Tower
Battista, R. C., Rivero, R. J. V., & Pfeil, M. S. (2021) · Structural Engineering International · doi:10.1080/10168664.2021.1953425 · Cited by 1
Roy, T., & Matsagar, V. A. (2022) · Sustainable and Resilient Infrastructure · doi:10.1080/23789689.2022.2115263 · Cited by 1
“…ground motions and wind forces has been significant to obtain the responses, which can be observed from the extensive literature survey conducted (Kwok & Samali, 1995; Chang, 1999; Yalla & Kareem, 2000; D. Lee & Taylor, 2001; Soong & Spencer, 2002; Guclu & Sertbas, 2005; Ikeda, 2009; Samanta &…”
BackgroundCOMPARISONS OF A TALL LATTICE WIND TOWER RESPONSE WITH AND WITHOUT A TMD
Henriques, J., & de Barros, R. C. (2014) · COMPDYN Proceedings · doi:10.7712/120113.4526.c1663 · Cited by 1
“Kwok and Samali [20] also studied the behavior of a TMD in tall buildings subjected to the action of wind and, according to them, the considerations presented about the effectiveness of a TMD in response of a system of one degree of freedom can also be extended to other solid structures – such as in the case of tall b…”
BackgroundActive Control of Pendulum Tuned Mass Dampers for Tall Buildings Subject to Wind Load
Eltaeb, M. A. (2017) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Active Multi Degree-of-Freedom Pendulum Tuned Mass Damper
Eltaeb, M. A., & Kashani, R. (2018) · Proceedings of the World Congress on Civil, Structural, and Environmental Engineering · doi:10.11159/icsenm18.107 · Cited by 1
“The effectiveness of a tuned mass damper can be increased by introducing a controllable element into its make-up, resulting in an active tuned mass damper (ATMD) [1], [2], [3], [4].”
BackgroundValencia, L. A. L., Ramírez-Acevedo, M., de Brito, J. L., Caicedo, D., & Farbiarz, Y. (2021) · COMPDYN Proceedings · doi:10.7712/120121.8797.18482 · Cited by 1
“[1] K.C. Kwok, B. Samali, Performance of tuned mass dampers under wind loads.”
MethodWind-Induced Vibration Control on Transmission Tower
Roy, S., Kundu, C. K., & Jena, B. (2022) · Lecture notes in civil engineering · doi:10.1007/978-981-16-8433-3_65 · Cited by 1
Dhanush, S., Yathish, N. V., & Shastry, K. (2022) · Structural integrity · doi:10.1007/978-3-031-05509-6_35 · Cited by 1
Análise dinâmica não linear de uma turbina eólica offshore monopile com TMD
Zwierzikowski, P. D. G. (2019) · Repositório Digital Institucional da UFPR (Universidade Federal do Paraná) · Cited by 1
Demetriou, D. (2017) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 1
Mitigating wind induced effects on tall buildings through aerodynamic modifications
Share, F. A. (2020) · Iowa State University Digital Repository (Iowa State University) · doi:10.31274/etd-20210114-5 · Cited by 1
Gasparetto, V. E. L. (2021) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2021-14645 · Cited by 1
Distributed, broadband vibration control devices using nonlinear approaches
Bao, B. (2016) · theses.fr (ABES) · doi:10.70675/bc3df0b9z0cdez4a75z9779z2f6fe508e1ad · Cited by 1
New design of tuned vibration absorber for wide frequency range application
Ghazali, M. H. (2015) · UTHM Institutional Repository (Universiti Tun Hussein Onn Malaysia)
Numerical analysis of suppressing vibration for flexible beam with inlaid viscous fluid unit
Wang, J., & Xu, H. (2010) · International Conference on Mechanical and Electrical Technology · doi:10.1109/icmet.2010.5598443
New Strategy Suppressing Vibration for Euler Beam by Using Impact Damping of Inlaid Steel Ball
Wang, J. W., & Xu, H. (2010) · Advanced materials research · doi:10.4028/www.scientific.net/amr.156-157.1122
Model elementów sprężysto-tłumiących w mechanicznych tłumikach drgań
Ciurej, H., & Masłowski, R. (2005) · Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Vibration control system with digitally adjustable electromagnetic damping and stiffness
Zhai, C., Xu, M., Feng, B., Gan, Y., & Hanaor, D. A. H. (2014) · Cross Connect (Southern Cross University)
Control of wind-induced vibration by combined tuned damper for super tall buildings
Wang, L., Zheng, Y., & Zhao, X. (2015) · Report · doi:10.2749/222137815818358772
Design of multiple tuned mass dampers for mitigation of wind induced vibrations
Chinien, L. V. (2000) · OpenGrey (Institut de l'Information Scientifique et Technique)
Passive Control by Pendulum TMD
de Barros, R. C., & Sousa, C. M. A. E. (2017) · WSEAS TRANSACTIONS on SYSTEMS archive
Earthquake Damping Device for Steel Frame
Ramli, M. Z., Delfy, D., Adnan, A., & Torman, Z. (2018) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/140/1/012151
Active strategies with TMDs for control of wind turbine vibrations
Fitzgerald, B. (2012) · Arrow@dit (Dublin Institute of Technology)
Metadata
- Authors
- Kwok, K. C. S., & Samali, B.
- Affiliations
- University of Technology Sydney (AU)
- Venue
- Engineering Structures
- Publisher
- Elsevier BV
- Published
- 1995-11
- Volume
- 17
- Issue
- 9
- Pages
- 655-667
- ISSN
- 0141-0296 (ISSN-L)
- OpenAlex
- W1984484262
- Cited by
- 206
- References
- 20
- Citations by year
- 2026: 7 · 2025: 9 · 2024: 8 · 2023: 11 · 2022: 12 · 2021: 19 · 2020: 19 · 2019: 14 · 2018: 12 · 2017: 10 · 2016: 11 · 2015: 10 · 2014: 6 · 2013: 7 · 2012: 4
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Engineering Structures (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic and Structural Analysis of Tall Buildings
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Vibration Analysis
- Keywords
- tuned mass damper, active tuned mass damper, passive tuned mass damper, wind loads, high-rise buildings, structural vibration control, dynamic response reduction, full-scale measurements, earthquake response, TMD parameter optimization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.