Performance of tuned mass dampers under wind loads
The DOI matches its Crossref record; 19 of the 20 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
BISHOP, R. E. D. (1957) · Nature · doi:10.1038/179504a0 · Cited by 1,636
Random Vibration in Mechanical Systems
(1963) · Elsevier eBooks · doi:10.1016/c2013-0-12506-8 · Cited by 899
Control of Along‐Wind Response of Structures by Mass and Liquid Dampers
Xu, Y. L., Samali, B., & Kwok, K. C. S. (1992) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1992)118:1(20 · Cited by 189
Self-citationXu, Y. L., Kwok, K. C. S., & Samali, B. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90519-g · Cited by 70
Self-citationControl of wind-induced tall building vibration by tuned mass dampers
Xu, Y. L., Kwok, K. C. S., & Samali, B. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90518-f · Cited by 66
Self-citationWind response of a tower (Typhoon observation at the Nagasaki Huis Ten Bosch Domtoren)
Tamura, Y., Shimada, K., & Kazuki, H. I. B. I. (1993) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(93)90086-4 · Cited by 62
Full-scale measurements of wind-induced acceleration response of Sydney Tower
Kwok, K. C. S., & Macdonald, P. A. (1990) · Engineering Structures · doi:10.1016/0141-0296(90)90002-a · Cited by 53
Self-citationEffect of tuned mass dampers on wind induced response of tall buildings
Tanaka, H., & MAK, C. Y. (1983) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(83)90037-5 · Cited by 41
Tuned active dampers installed in the Minato Mirai (MM) 21 landmark tower in Yokohama
Yamazaki, S., Nagata, N., & Abiru, H. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90618-k · Cited by 34
Time history response of a tall building with a tuned mass damper under wind force
Kawaguchi, A., Teramura, A., & Omote, Y. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90619-l · Cited by 33
Semianalytical Method for Parametric Study of Tuned Mass Dampers
Xu, Y. L., & Kwok, K. C. S. (1994) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1994)120:3(747 · Cited by 29
Self-citationSuppression of wind-induced vibrations of buildings
Tamura, Y. (1990) · Wind Engineers JAWE · doi:10.5359/jawe.1990.44_71 · Cited by 23
Full-scale measurements of wind-induced response of Sydney Tower
Kwok, K. C. S. (1983) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(83)90033-8 · Cited by 21
Self-citationTorsion response and vibration suppression of wind-excited buildings
Xu, Y. L., Kwok, K. C. S., & Samali, B. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90623-i · Cited by 20
Self-citationFull-scale measurements of wind actions on Chiba Port Tower
Ohtake, K., Mataki, Y., Ohkuma, T., Kanda, J., & KITAMURA, H. (1992) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(92)90661-s · Cited by 20
Wind tunnel investigation of active vibration control of tall buildings
Facioni, R. J., Kwok, K. C. S., & Samali, B. (1995) · Journal of Wind Engineering and Industrial Aerodynamics · doi:10.1016/0167-6105(94)00056-j · Cited by 17
Self-citationTuned Active Dampers Installed in the Yokohama Landmark Tower
Abiru, H., Fujishiro, M., Matsumoto, T., Yamazaki, S., & Nagata, N. (1994) · JSME international journal Ser C Dynamics control robotics design and manufacturing · doi:10.1299/jsmec1993.37.450 · Cited by 9
Tuned Active Dampers Installed in the Yokohama Landmark Tower
Abiru, H. (1992) · The journal of the INCE of Japan · doi:10.11372/souonseigyo1977.16.135 · Cited by 4
Wind resistant design of a tall building with an ellipsoidal cross section
Itoh, M. (1992) · The Structural Design of Tall Buildings · doi:10.1002/tal.4320010203 · Cited by 2
Research works printed but not linked: 7
- 1994, Putting a damper on swaying building, The Sydney Morning Herald, 6
- Konno, 1989, Examples of practical applications of dampers, (4) Higashiyama Sky Tower, Struct.
- 1975, Hancock Tower to get dampers, Engineering News Record, 11
- Kitamura, 1988, Chiba Port Tower: full-scale measurement of wind actions (Part 1) Organisation, measurement system and strong wind data, J. Wind Engng, 37, 401
- Ibe, 1988, Fukuoka Tower project, Build. Lett.
- Kihara, 1989, Examples of practicable applications of dampers, (1) Fukuoka Tower, Struct.
- Yamashita, 1992, Wind resistant design of a tall building — damping systems for ACT Tower, Think 33, 10, 24
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
“Kwok and Samali (1995) showed the performance of the Please cite this article as: S. Elias, V. Matsagar, Research developme dampers, Annual Reviews in Control (2017), https://doi.org/10.1016/j.arc MDs in mitigation of dynamic response of the tall structures sub- ected to wind loads.”
BackgroundInfluentialMitigation of motions of tall buildings with specific examples of recent applications
Kareem, A., Kijewski, T., & Tamura, Y. (1999) · Wind and Structures · doi:10.12989/was.1999.2.3.201 · Cited by 440
Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review
Yang, F., Sedaghati, R., & Esmailzadeh, E. (2022) · Journal of Vibration and Control · doi:10.1177/1077546320984305 · Cited by 306
“Vickery et al. (1983), Xu and Kwok (1994), and Kwok and Samali (1995) studied the effectiveness of the TMD system for the building structures, which were modeled as SDOF structures, subjected to wind loadings.”
BackgroundMethodMethodologies to mitigate wind-induced vibration of tall buildings: A state-of-the-art review
Jafari, M., & Alipour, A. A. (2020) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101582 · Cited by 203
Control of flapwise vibrations in wind turbine blades using semi-active tuned mass dampers
Arrigan, J., Pakrashi, V., Basu, B., & Nagarajaiah, S. (2011) · Structural Control and Health Monitoring · doi:10.1002/stc.404 · Cited by 168
“One of the first buildings to have a TMD installed was the John Hancock Building in Boston, details of which can be found in Kwok and Samali [12].”
Metadata
- Authors
- Kwok, K. C. S., & Samali, B.
- Affiliations
- University of Technology Sydney (AU)
- Venue
- Engineering Structures
- Publisher
- Elsevier BV
- Published
- 1995-11
- Volume
- 17
- Issue
- 9
- Pages
- 655-667
- ISSN
- 0141-0296 (ISSN-L)
- OpenAlex
- W1984484262
- Cited by
- 206
- References
- 20
- Citations by year
- 2026: 7 · 2025: 9 · 2024: 8 · 2023: 11 · 2022: 12 · 2021: 19 · 2020: 19 · 2019: 14 · 2018: 12 · 2017: 10 · 2016: 11 · 2015: 10 · 2014: 6 · 2013: 7 · 2012: 4
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Engineering Structures (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Civil and Structural Engineering › Seismic and Structural Analysis of Tall Buildings
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Engineering and Vibration Analysis
- Keywords
- tuned mass damper, active tuned mass damper, passive tuned mass damper, wind loads, high-rise buildings, structural vibration control, dynamic response reduction, full-scale measurements, earthquake response, TMD parameter optimization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.