CoChat

Stochastic analysis of myoelectric temporal signatures for multifunctional single-site activation of prostheses and orthoses

Graupe, Daniel, Salahi, Javad, Zhang, DeSong · 1985 · Journal of Biomedical Engineering
Cited by 97

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This paper is concerned with a stochastic time-series analysis of the temporal signatures of myoelectric (ME) signals including the determination of model order and sampling rate. The paper considers the use of time-series parameters for the activation of artificial limbs for high-level amputees, of stimulation electrodes or of powered braces for paralysed persons, in several degrees of freedom, from a single or two surface-electrode pairs at locations where considerable ME cross-talk exists. The multifunctional capability from a single site is based on the differences between the time-series (TS) parameters for different muscle activation patterns at the same ME site, these differences being thus used for limb function discrimination via easily trainable muscle activation patterns at the vicinity of the electrode site. Specifically, the analysis is in terms of identifying the AR parameters of a time-domain autoregressive (AR) signature model both for the complete ME spectrum and for parts thereof, and in terms of the autocorrelation of the signal and of the models residual. Determination of sampling rate and of model orders is discussed in detail. It is shown that, using online real-time analysis, differences in the AR time-series parameters can be observed for different trainable patterns of muscle activation, at the same electrode location, even at the same ME power levels, as long as considerable cross-talk exists at the electrode site. These parameter differences can be accentuated if one considers the AR parameters for lower-frequency spectral windows. A case is made in this paper for employing TS analysis to squeeze out information in a distinct but low-level ripple of the low frequency spectrum of the signal. This information tends to be ignored in frequency domain, but is all that the AR parameters care for in TS analysis, since they are not concerned, with a flat-average low-frequency spectrum, i.e., its white-noise-like part, which is the residual term of the AR Model and not an AR parameter. Discrimination between different functions from a single electrode-site, at even the same power level, is thus shown to require considerable cross-talk at the given site, and to require the consideration of only the low-frequency part of the spectrum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0141-5425(85)90004-4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 97

Metadata

Authors
Graupe, D., Salahi, J., & Zhang, D.
Venue
Journal of Biomedical Engineering
Published
1985-01-01
Volume
7
Issue
1
Pages
18-29
ISSN
0141-5425 (ISSN-L)
OpenAlex
W2054538394
Cited by
97
References
1
FWCI
1.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.