Replacement of the rabbit medial meniscus with a polyester-carbon fibre bioprosthesis
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MANKIN, H. J., DORFMAN, H., LIPPIELLO, L., & ZARINS, A. (1971) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197153030-00009 · Cited by 1,963
KNEE JOINT CHANGES AFTER MENISCECTOMY
Fairbank, T. J. (1948) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.30b4.664 · Cited by 1,863
The Role of the Menisci in Force Transmission Across the Knee
Walker, P. S., & Erkiuan, M. J. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197506000-00027 · Cited by 1,117
Fukubayashi, T., & Kurosawa, H. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990887 · Cited by 813
Load-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint with or Without Menisci
KUROSAWA, H., FUKUBAYASHI, T., & NAKAJIMA, H. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198006000-00039 · Cited by 469
Load-Bearing in the Knee Joint
SHRIVE, N. G., O'CONNOR, J. J., & GOODFELLOW, J. W. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197803000-00046 · Cited by 355
Seedhom, B. B., & Hargreaves, D. J. (1979) · Engineering in Medicine · doi:10.1243/emed_jour_1979_008_051_02 · Cited by 334
Femorotibial weight-bearing areas. Experimental determination
Maquet, P., Van de Berg, A., & Simonet, J. (1975) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197557060-00005 · Cited by 139
The role of the meniscus in an instability model for osteoarthritis in the rabbit knee.
Minns, R. J., & Muckle, D. S. (1982) · PubMed · Cited by 10
Self-citation
Cited by
Bose, S., & Tarafder, S. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.11.017 · Cited by 958
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Amani, H., Arzaghi, H., Bayandori, M., Dezfuli, A. S., Pazoki‐Toroudi, H., Shafiee, A., & Moradi, L. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201900572 · Cited by 436
MESSNER, K., & GAO, J. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19320161.x · Cited by 431
Organic–Inorganic Surface Modifications for Titanium Implant Surfaces
de Jonge, L. T., Leeuwenburgh, S. C. G., Wolke, J. G. C., & Jansen, J. A. (2008) · Pharmaceutical Research · doi:10.1007/s11095-008-9617-0 · Cited by 361
Metadata
- Authors
- Wood, D. J., Minns, R. J., & Strover, A.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1990-01
- Volume
- 11
- Issue
- 1
- Pages
- 13-16
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W4300065620
- Cited by
- 214
- References
- 9
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.