Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 431

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment

MESSNER, KAROLA, GAO, JIZONG·1998·Journal of Anatomy

Abstract

The menisci and their insertions into bone (entheses) represent a functional unit. Thanks to their firm entheses, the menisci are able to distribute loads and therefore reduce the stresses on the tibia, a function which is regarded essential for cartilage protection and prevention of osteoarthrosis. The tissue of the hypocellular meniscal body consists mainly of water and a dense elaborate type I collagen network with a predominantly circumferential alignment. The content of different collagens, proteoglycans and nonproteoglycan proteins shows significant regional variations probably reflecting functional adaptation. The meniscal horns are attached via meniscal insertional ligaments mainly to tibial bone. At the enthesis, the fibres of the insertional ligaments attach to bone via uncalcified and calcified fibrocartilages. This anatomical configuration of gradual transition from soft to hard tissue, which is identical to other ligament entheses, is certainly essential for normal mechanical function and probably protects this vulnerable transition between 2 biomechanically different tissues from failure. Clinical treatment of meniscal tears needs to be based on these special anatomical and functional characteristics. Partial meniscectomy will preserve some of the load distribution function of the meniscus only when the meniscal body enthesis entity is preserved. Repair of peripheral longitudinal tears will heal and probably preserve the load distribution function of the meniscus, whereas radial tears through the whole meniscal periphery or more central and complex tears may be induced to heal, but probably do not preserve the load distribution function. There is no proof that replacement of the meniscus with an allograft can reestablish some of the important meniscal functions, and thereby prevent or reduce the development of osteoarthrosis which is common after meniscectomy. After implantation, major problems are the remodelling of the graft to inferior structural, biochemical and mechanical properties and its insufficient fixation to bone which fails to duplicate a normal anatomical configuration and therefore a functional meniscal enthesis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1469-7580.1998.19320161.x

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Cited by

See all 431

Metadata

Authors
MESSNER, K., & GAO, J.
Venue
Journal of Anatomy
Publisher
Wiley
Published
1998-08
Volume
193
Issue
2
Pages
161-178
ISSN
  • 0021-8782 (ISSN-L)
  • 1469-7580
OpenAlex
W2112275933
Cited by
431
References
50
FWCI
5.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment. https://app.cochat.ai/papers/10.1046/j.1469-7580.1998.19320161.x
The paper
MESSNER, K., & GAO, J. (1998). The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment. Journal of Anatomy. https://doi.org/10.1046/j.1469-7580.1998.19320161.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.