CoChat

Cytotoxicity of medical materials sterilized with vapour-phase hydrogen peroxide

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

A new sterilization system using vapour-phase hydrogen peroxide (VPHP) was recently developed. The cytotoxicity of various medical materials sterilized by the VPHP sterilization system was investigated. After VPHP sterilization, polystyrene, polyurethane (PU8), blend material of silicone and polyurethane (Sil/PU6), poly(methyl methacrylate) (PMMA), fluorosilicone acrylate and poly(2-hydroxyethyl methacrylate) (HEMA) showed strong cytotoxicity, whereas polyethylene and polypropylene did not. Although the cytotoxic potential of most materials is reduced by extension of the aeration time, HEMA and PMMA still retained strong cytotoxicity after 12 h aeration. Addition of catalase to the cell culture eliminated the cytotoxicity of sterilized polystyrene and PU8. Hydrogen peroxide (H2O2) residues remaining in the sterilized materials were determined. Large amounts of H2O2 (5.1-186 micrograms) were detected in HEMA, PU8, Sil/PU6 and PMMA. In contrast, silicone and polyethylene contained low levels of H2O2. The amounts of residual H2O2 in the materials decreased with increasing aeration time, but the elimination rate of H2O2 differed among the test materials. The cytotoxic potential of the VPHP-sterilized materials correlated with the amounts of residual H2O2 present. These results indicated that the cytotoxicity of VPHP-sterilized materials was caused by the residual H2O2. To generalize the developed VPHP sterilization system for various medical devices, it is important to validate t…

Overview

Integrity signals

Registry

Crossref · 10.1016/0142-9612(95)92115-m

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 32 references

Research works printed but not linked: 2

  1. Naguib, 1972, The effect of hydrogen peroxide on the bacteriological quality and nutritive value of milk, Milchwissenschaft, 27, 758
  2. Wang, 1986, Sporicidal properties of mixtures of hydrogen peroxide vapor and hot air, Food Technol, 40, 60

Cited by

See all 39

Metadata

Authors
Ikarashi, Y., Tsuchiya, T., & Nakamura, A.
Affiliations
National Institute of Health Sciences (JP)
Corresponding author
Ikarashi, Yoshiaki
Venue
Biomaterials
Publisher
Elsevier BV
Published
1995
Volume
16
Issue
3
Pages
177-183
ISSN
0142-9612 (ISSN-L)
OpenAlex
W2008981443
Cited by
31
References
30
Citations by year
2025: 2 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 4
FWCI
0.28
Type
journal article
Language
en
Open access
closed
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Biomaterials (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
  • Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
Keywords
cytotoxicity, residual hydrogen peroxide, aeration, medical device sterilization, polystyrene, polyurethane, silicone, poly(methyl methacrylate), poly(2-hydroxyethyl methacrylate), catalase
MeSH terms
Acrylates, Animals, Catalase, Cells, Cultured, Cricetulus, Dose-Response Relationship, Drug, Fibroblasts, Cricetinae, Hydrogen Peroxide, Methacrylates, Methylmethacrylates, Polystyrenes, Polyurethanes, Sterilization, Volatilization, CHO Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cytotoxicity of medical materials sterilized with vapour-phase hydrogen peroxide. https://app.cochat.ai/papers/10.1016/0142-9612(95)92115-m
The paper
Ikarashi, Y., Tsuchiya, T., & Nakamura, A. (1995). Cytotoxicity of medical materials sterilized with vapour-phase hydrogen peroxide. Biomaterials. https://doi.org/10.1016/0142-9612(95)92115-m

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.