The in vivo auto-oxidation of polyether polyurethane by metal ions
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The first large scale use of polyether polyurethane elastomers in long term human implants was as insulation for cardiac and neurologic pacing leads. While the performance of these polymers has generally been very good over a 14-year period, several failure mechanisms have been discovered that involve interactions between the devices, materials and the body. One of these is auto-oxidation of soft segment ether through the intermediate action of certain transition metal ions, derived from conductor wires by corrosion processes. Biologically produced oxidants appear to be an accelerating factor. In this study, Pellethane 2363-80A tubing containing conductor coils or mandrels of various metals or controls were implanted in rabbits. Explants were analyzed as a function of implant time by optical and scanning electron microscopy, electron dispersive analysis by X-ray, stress-strain, FTIR, GPC and AA spectrophotometry. Only cobalt produced bulk oxidative degradation while surface damage was found in the presence of cobalt bearing alloys. No evidence of significant auto-oxidation was found in the presence of silver, nickel, chromium, molybdenum, iron, titanium, platinum, 304 stainless steel, glass or empty tubing. The combination of polyether polyurethane and metals (especially those containing cobalt) in an implantable device must be carefully evaluated for biostability prior to human use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Some aspects of macrophage behavior at the implant interface
Salthouse, T. N. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180407 · Cited by 176
Cited by
Wilkoff, B. L., Love, C. J., Byrd, C. L., Bongiorni, M. G., Carrillo, R. G., Crossley, G. H., Epstein, L. M., Friedman, R. A., Kennergren, C. E. H., Mitkowski, P., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.05.020 · Cited by 1,024
Degradation and stabilization of polyurethane elastomers
Xie, F., Zhang, T., Bryant, P., Kurusingal, V., Colwell, J. M., & Laycock, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.12.003 · Cited by 722
Santerre, J. P., Woodhouse, K., Laroche, G., & Labow, R. S. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.079 · Cited by 718
“It was the work of Ken Stokes, which initially provided the most comprehensive theory of in vivo biodegradation in his description of ESC [2,4–7].”
BackgroundMethodInfluentialPolyurethane Elastomer Biostability
Stokes, K., McVenes, R., & Anderson, J. M. (1995) · Journal of Biomaterials Applications · doi:10.1177/088532829500900402 · Cited by 366
Self-citationZhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
Metadata
- Authors
- Stokes, K., Urbanski, P., & Upton, J.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 1989-01
- Volume
- 1
- Issue
- 3
- Pages
- 207-230
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W1967162319
- Cited by
- 107
- References
- 2
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The in vivo auto-oxidation of polyether polyurethane by metal ions. https://app.cochat.ai/papers/10.1163/156856290x00062
- The paper
- Stokes, K., Urbanski, P., & Upton, J. (1989). The in vivo auto-oxidation of polyether polyurethane by metal ions. Journal of Biomaterials Science, Polymer Edition. https://doi.org/10.1163/156856290x00062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.