The DOI matches its Crossref record.
Use of porous polyurethanes for meniscal reconstruction and meniscal prostheses
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A meniscal replica implanted contained only fibro-cartilage after 18 weeks and decreased the degradation of the articular cartilage.”
From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as De Groot et al.., 1996
In the citing paper
“A meniscal replica implanted contained only fibro-cartilage after 18 weeks and decreased the degradation of the articular cartilage.”
From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as De Groot et al.., 1996
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 39
- King, 1936, The healing of semilunar cartilage, J Bone Surg, 18-A, 333
- Ghosh, 1983, Effect of postoperative immobilisation on the regrowth of the knee joint semilunar cartilage: an experimental study, J Orthop Res, 1, 153, 10.1002/jor.1100010206 · DOI
- Gosch, 1987, The knee joint meniscus, Clin Orthop Rel Res, 224, 52, 10.1097/00003086-198711000-00008 · DOI
- Fairbank, 1948, Knee joint changes after meniscectomy, J Bone Joint Surg, 30B, 664, 10.1302/0301-620X.30B4.664 · DOI
- DeHaven, 1990, Decision-making factors in the treatment of meniscus lesions, Clin Orthop, 252, 49, 10.1097/00003086-199003000-00007 · DOI
- Veth, 1983, Repair of the meniscus, Clin Orthop, 175, 258, 10.1097/00003086-198305000-00043 · DOI
- Ghadially, 1986, Experimental methods of repairing injured menisci, J Bone Joint Surg, 68-B1, 106, 10.1302/0301-620X.68B1.3753606 · DOI
- Veth, 1983, An experimental study of reconstructive procedure in lesion of the meniscus: use of synovial flap and carbon fiber implants for artificially made lesions in meniscus of the rabbit, Clin Orthop, 181, 250, 10.1097/00003086-198312000-00039 · DOI
- Arnoczky, 1990, Meniscal replacement using a cryopreserved allograft, Clin Orthop Rel Res, 252, 121, 10.1097/00003086-199003000-00017 · DOI
- Stone, 1990, Future directions. Collagen based prosthesis for meniscal regeneration, Clin Orthop Rel Res, 252, 129, 10.1097/00003086-199003000-00018 · DOI
- Elema, 1990, Use of biodegradable polymer implants in meniscus reconstruction. 2) Biological evaluation of porous biodegradable implants in menisci, Colloid Polym Sci, 268, 1082, 10.1007/BF01410673 · DOI
- de Groot, 1990, Use of biodegradable polymer implants in meniscus reconstruction. 1) Preparation of porous biodegradable polyurethanes for the reconstruction of the meniscus, Colloid Polym Sci, 268, 1073, 10.1007/BF01410672 · DOI · Paper page
- Klompmaker, 1991, Porous polymer implants for repair of meniscal lesions: a preliminary study in dogs, Biomaterials, 12, 810, 10.1016/0142-9612(91)90066-J · DOI
- Szycher, 1988, Biostability of polyurethane elastomers: a critical review, J Biomater Appl, 3, 297, 10.1177/088532828800300207 · DOI
- Bonart, 1968, X-ray investigations concerning the physical structure of cross-linking in segmented urethane elastomers, J Macromol Sci Phys, B2, 115, 10.1080/00222346808212867 · DOI
- Veth, 1986, Experimental meniscal lesions reconstructed with a carbon fiber-poly(llactide) graft, Clin Orthop Rel Res, 202, 286, 10.1097/00003086-198601000-00041 · DOI
- Klompmaker, 1992, Meniscal repair by fibrocartilage? An experimental study in the dog, J Orthop Res, 10, 359, 10.1002/jor.1100100308 · DOI
- van Bogart, 1981, Annealinginduced morphological changes in segmented elastomers, Polymer, 22, 1428, 10.1016/0032-3861(81)90250-0 · DOI
- Schollenberger, 1978, Thermoplastic polyurethane elastomer structure-thermal transition relation, Polym Prep Am Chem Soc Div Polym Chem, 19, 17
- van Bogart, 1983, Structure-property relationships in polycaprolactone polyurethanes, J Polym Sci Phys Edn, 21, 65, 10.1002/pol.1983.180210106 · DOI
- Benjamin, 1990, Fibrocartilage research review, Acta Anat, 171, 1
- Proctor, 1989, Material properties of the normal medial bovine meniscus, J Orthop Res, 7, 771, 10.1002/jor.1100070602 · DOI
- van Bogart, 1980, Morphology and properties of short segment block copolymers, J Macromol Sci Phys, B17, 267, 10.1080/00222348008213125 · DOI
- Dieter, 1987, Aliphatic polyurethane elastomers with high performance properties, Polym Engng Sci, 27, 673, 10.1002/pen.760270912 · DOI
- Sung, 1975, Infrared studies of hydrogen bonding in toluene diisocyanate based polyurethanes, Macromolecules, 8, 68, 10.1021/ma60043a015 · DOI
- Sung, 1977, Temperature dependence of hydrogen bonding in toluene diisocyanate based polyurethanes, Macromolecules, 10, 452, 10.1021/ma60056a041 · DOI
- Lyman, 1960, Polyurethanes. I. The solution polymerization of diisocyanates with ethylene glycol, J Polym Sci, 45, 49, 10.1002/pol.1960.1204514505 · DOI
- Aubert, 1985, Low-density microcellular polystyrene foams, Polymer, 26, 2047, 10.1016/0032-3861(85)90186-7 · DOI
- Bos, 1991, Degradation of and tissue reaction to biodegradable poly(l-lactide) for use as internal fixation of fractures. A study in rats, Biomaterials, 12, 33, 10.1016/0142-9612(91)90128-W · DOI
- Grijpma, 1994, (Co)polymers of l-lactide, I. Synthesis, thermal properties and hydrolytic degradation, Macromol Chem Phys, 195, 1633, 10.1002/macp.1994.021950515 · DOI
- Fukuzaki, 1990, Synthesis of low-molecular-weight co-poly(l-lactide acid/ε-caprolactone) by direct copolycondensation in the absence of catalyst and enzymatic degradation of the polymers, Polymer, 31, 2006, 10.1016/0032-3861(90)90031-S · DOI
- Camberlin, 1984, Phase segregation kinetics in segmented linear polyurethanes: relation between equilibrium time and chain mobility and between equilibrium degree of segregation and interaction parameter, J Polym Sci Polym Phys Edn, 22, 1835, 10.1002/pol.1984.180221011 · DOI
- Warhurst, 1986, Comparison of tear test methods, Polym Test, 6, 463, 10.1016/0142-9418(86)90020-6 · DOI
- Greensmith, 1955, Rupture of rubber. III. Determination of tear properties, J Polym Sci, 18, 189, 10.1002/pol.1955.120188803 · DOI
- Bhowmick, 1983, Tear strength of elastomers under threshold conditions, Rubber Chem Technol, 56, 226, 10.5254/1.3538115 · DOI
- Mueller, 1971, The fracture energy and some mechanical properties of a polyurethane elastomer, Trans Soc Rheol, 15, 217, 10.1122/1.549209 · DOI
- Bhowmick, 1986, Tear strength of elastomers over a range of rates, temperatures and crosslinking: tearing energy spectra, J Mater Sci, 21, 3927, 10.1007/BF02431631 · DOI
- Agagon, 1975, Threshold fracture energies for elastomers, Rubber Chem Technol, 13, 1903
- de Gennes, 1988, Fracture d'un adhésif faiblement réticulé, CR Acad Sci Paris, t.307, 1949
Cited by
Sorted by citations
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765
Zheng, H., Huang, W., He, B., Tan, H., Lin, P., & Zha, Z. (2020) · Pharmaceutical Biology · doi:10.1080/13880209.2020.1743325 · Cited by 6
Metadata
- Authors
- de Groot, J. H., de Vrijer, R., Pennings, A. J., Klompmaker, J., Veth, R. P. H., & Jansen, H. W. B.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 1996-01
- Volume
- 17
- Issue
- 2
- Pages
- 163-173
- ISSN
- 0142-9612
- Cited by
- 125
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review