Measurement error in visually scored electrophysiological data: respiration during sleep
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Electrophysiological sleep studies employ the simultaneous recording of multiple physiological parameters. These data are often scored and analyzed visually, i.e. by trained human scorers. In this study, we investigated the measurement error inherent in visual evaluation of respiratory disturbances during human sleep. Three trained scorers independently evaluated twenty-eight all-night sleep recordings. Results indicated that the scorers achieved high agreement on only selected variables. Scorers' experience did not affect the reliability and independent judgements of recording quality did not account for the discrepancies. These findings, although most relevant for the specific parameters studied here, as well as for these scoring criteria, subjects, and techniques, document the unreliability of certain visually scored sleep data. The present paradigm may be useful in evaluating other types of measurement error.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, distinguishing event subtypes (obstructive, central, and mixed) is much more difficult, resulting in worse scorer reliability.22”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [22]
Citations
Cites
ON THE METHODS AND THEORY OF RELIABILITY
BARTKO, J. J., & CARPENTER, W. T. (1976) · The Journal of Nervous and Mental Disease · doi:10.1097/00005053-197611000-00003 · Cited by 1,310
Measurement of the separate volume changes of rib cage and abdomen during breathing
Konno, K., & Mead, J. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.22.3.407 · Cited by 1,027
Statistics: A Biomedical Introduction
Krótki, K. J., Brown, B. W., Hollander, M., & Krotki, K. J. (1980) · International Statistical Review / Revue Internationale de Statistique · doi:10.2307/1402416 · Cited by 445
Statistics: A Biomedical Introduction.
Marriott, F. H. C., Brown, B. W., & Hollander, M. (1978) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2344819 · Cited by 222
Respiration During Sleep in the Aged Human
Carskadon, M. A., & Dement, W. C. (1981) · Journal of Gerontology · doi:10.1093/geronj/36.4.420 · Cited by 186
Self-citationA new method for evaluating antiarrhythmic drug efficacy.
Sami, M., KRAEMER, H. C., Harrison, D. C., Miller, N. H., Shimasaki, C., & DeBusk, R. F. (1980) · Circulation · doi:10.1161/01.cir.62.6.1172 · Cited by 143
Self-citationBreathing Abnormalities During Sleep
Tobin, M. J., Cohn, M. A., & Sackner, M. A. (1983) · Archives of Internal Medicine · doi:10.1001/archinte.1983.00350060149023 · Cited by 55
Sleep related breathing disorders in older men: A search for underlying mechanisms
McGinty, D., Littner, M. R., Beahm, E. K., Ruiz-Primo, E., Young, E., & Sowers, J. R. (1982) · Neurobiology of Aging · doi:10.1016/0197-4580(82)90022-7 · Cited by 50
KRAEMER, H. C., & Korner, A. F. (1976) · Psychological Bulletin · doi:10.1037/0033-2909.83.5.914 · Cited by 42
Self-citationKRAEMER, H. C., & Korner, A. F. (1976) · Psychological Bulletin · doi:10.1037//0033-2909.83.5.914 · Cited by 34
Self-citation
Research works printed but not linked: 3
- Metropolotican Life Insurance Company, 1959, Statistical Bulletin, 40, 1
- Milledge, 1977, Inductive plethysmography: a new respiratory transducer, J. Physiol. (Lond.), 267, 48
- Miles, L.E., Rule, R.B., Benson, K. and Dement, W.C. (in press) Measurement of airflow and tidal volume using the vitalog home monitor, Ann. Biomed. Eng.
Cited by
Snoring and sleep apnea. A population study in Australian men.
Bearpark, H., Elliott, L., Grunstein, R., Cullen, S., Schneider, H., Althaus, W., & Sullivan, C. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.151.5.7735600 · Cited by 490
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Reliability of Scoring Respiratory Disturbance Indices and Sleep Staging
Whitney, C. W., Gottlieb, D. J., Redline, S., Norman, R. G., Dodge, R. R., Shahar, E., Surovec, S., & Nieto, F. J. (1998) · Sleep · doi:10.1093/sleep/21.7.749 · Cited by 327
The Scoring of Respiratory Events in Sleep: Reliability and Validity
Redline, S., Budhiraja, R., Kapur, V., Marcus, C. L., Mateika, J. H., Mehra, R., Parthasarthy, S., Somers, V. K., Strohl, K. P., Gozal, D., et al. (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26818 · Cited by 305
Indications and Standards for Cardiopulmonary Sleep Studies
(1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.2.559 · Cited by 303
Performance of an Automated Polysomnography Scoring System Versus Computer-Assisted Manual Scoring
Malhotra, A., Younes, M., Kuna, S. T., Benca, R., Kushida, C. A., Walsh, J., Hanlon, A., Staley, B., Pack, A. I., & Pien, G. W. (2013) · Sleep · doi:10.5665/sleep.2548 · Cited by 222
Measurement of Sleep-related Breathing Disturbances in Epidemiologic Studies
Redline, S., Tosteson, T., Boucher, M. A., & Millman, R. P. (1991) · Chest · doi:10.1378/chest.100.5.1281 · Cited by 206
Sleep apnea and mortality in an aged cohort.
Bliwise, D. L., Bliwise, N. G., Partinen, M., Pursley, A. M., & Dement, W. C. (1988) · American Journal of Public Health · doi:10.2105/ajph.78.5.544 · Cited by 181
Self-citationSteenkiste, T. V., Groenendaal, W., Deschrijver, D., & Dhaene, T. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2886064 · Cited by 160
Description and Validation of the Apnea Risk Evaluation System
Westbrook, P. R., Levendowski, D. J., Cvetinovic, M. M., Zavora, T., Velimirovic, V., Henninger, D., & Nicholson, D. (2005) · CHEST Journal · doi:10.1378/chest.128.4.2166 · Cited by 147
Automated sleep stage scoring of the Sleep Heart Health Study using deep neural networks
Zhang, L., Fabbri, D., Upender, R. P., & Kent, D. T. (2019) · SLEEP · doi:10.1093/sleep/zsz159 · Cited by 113
Interobserver Variability in Recognizing Arousal in Respiratory Sleep Disorders
DRINNAN, M. J., MURRAY, A., GRIFFITHS, C. J., & JOHN GIBSON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.2.9705035 · Cited by 106
Valencia-flores, M., Bliwise, D. L., Guilleminault, C., Cilveti, R., & Clerk, A. (1996) · Journal of Clinical and Experimental Neuropsychology · doi:10.1080/01688639608408275 · Cited by 105
Self-citationUtley, D. S., Shin, E. J., Clerk, A. A., & Terris, D. J. (1997) · The Laryngoscope · doi:10.1097/00005537-199706000-00005 · Cited by 98
Risk Factors for Sleep Disordered Breathing in Heterogeneous Geriatric Populations
Bitwise, D. L., Feldman, D. E., Bliwise, N. G., Carskadon, M. A., Kraemer, H. C., North, C. S., Petta, D. E., Seidel, W. F., & Dement, W. C. (1987) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1987.tb01342.x · Cited by 91
Self-citationYesavage, J., Bliwise, D., Guilleminault, C., Carskadon, M., & Dement, W. (1985) · Sleep · doi:10.1093/sleep/8.1.30 · Cited by 90
Self-citationComparison of the NovaSom QSG™, a new sleep apnea home-diagnostic system, and polysomnography
Reichert, J. A., Bloch, D. A., Cundiff, E., & Votteri, B. A. (2002) · Sleep Medicine · doi:10.1016/s1389-9457(02)00234-4 · Cited by 89
Sleep-disordered breathing and periodic limb movements in sleep in older patients with schizophrenia
Ancoli‐Israel, S., Martin, J. L., Jones, D., Caligiuri, M. P., Patterson, T. L., Harris, M. J., & Jeste, D. V. (1999) · Biological Psychiatry · doi:10.1016/s0006-3223(98)00166-8 · Cited by 83
Ballester, E., Badia, Hernandez, L., Farre, R., Navajas, D., & Montserrat, J. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.11040880 · Cited by 82
Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System
Punjabi, N. M., Shifa, N., Dorffner, G., Patil, S., Pien, G., & Aurora, R. N. (2015) · Sleep · doi:10.5665/sleep.5046 · Cited by 67
Sleep Apnea Detection From Variational Mode Decomposed EEG Signal Using a Hybrid CNN-BiLSTM
Mahmud, T., Khan, I. A., Mahmud, T. I., Fattah, S. A., Zhu, W., & Ahmad, M. O. (2021) · IEEE Access · doi:10.1109/access.2021.3097090 · Cited by 65
Zhang, X., Landsness, E. C., Chen, W., Miao, H., Tang, M., Brier, L. M., Culver, J. P., Lee, J., & Anastasio, M. A. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109421 · Cited by 40
Night-to-night variability in sleep in cystic fibrosis
Milross, M., Piper, A. J., Norman, M. B., Willson, G., Grunstein, R. R., Sullivan, C. E., & Bye, P. T. P. (2002) · Sleep Medicine · doi:10.1016/s1389-9457(02)00030-8 · Cited by 38
Utility of Technologist Editing of Polysomnography Scoring Performed by a Validated Automatic System
Younes, M. K., Thompson, W., Leslie, C., Egan, T., & Giannouli, E. (2015) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201411-512oc · Cited by 37
Epidemiology of Age-Dependence in Sleep-Disordered Breathing in Old Age: The Bay Area Sleep Cohort
Bliwise, D. L. (2009) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2008.11.004 · Cited by 32
Self-citationIncident Sleep Disordered Breathing in Old Age
Bliwise, D. L., Colrain, I. M., Swan, G. E., & Bliwise, N. G. (2010) · The Journals of Gerontology Series A · doi:10.1093/gerona/glq071 · Cited by 30
Self-citationSelf-Reported Excessive Daytime Somnolence and Impaired Respiration in Sleep
Sink, J., Bliwise, D. L., & Dement, W. C. (1986) · CHEST Journal · doi:10.1378/chest.90.2.177 · Cited by 31
Self-citationWard, N. R., Roldao, V., Cowie, M., Rosen, S. D., McDonagh, T. A., Simonds, A. K., & Morrell, M. J. (2013) · SLEEP · doi:10.5665/sleep.2960 · Cited by 28
Issues in Computerized Polysomnography
Hirshkowitz, M., & Moore, C. A. (1994) · SLEEP · doi:10.1093/sleep/17.2.105a · Cited by 24
Inter-Rater Reliability for Scoring Periodic Leg Movements in Sleep
Bliwise, D. L., Keenan, S. A., Bumburg, D., Mattice, C., Minkley, P., Pursley, A. M., & Zelonis, J. (1991) · SLEEP · doi:10.1093/sleep/14.3.249 · Cited by 22
Self-citationEvaluation of a Computerized Polysomnographic System
White, D. P., & Gibb, T. J. (1998) · SLEEP · doi:10.1093/sleep/21.2.188 · Cited by 19
Zubair, M., Mudavath, U. K. N., Tripathy, R. K., Alhartomi, M. A., Alzahrani, S., & Ahamed, S. R. (2023) · IEEE Transactions on Artificial Intelligence · doi:10.1109/tai.2023.3329455 · Cited by 19
Automated Scoring of Sleep and Associated Events
Anderer, P., Ross, M., Cerny, A., & Shaw, E. (2022) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-06413-5_7 · Cited by 18
Sleep disordered breathing in the elderly: Review and methodological comment
Berry, D. T. R., & Phillips, B. A. (1988) · Clinical Psychology Review · doi:10.1016/0272-7358(88)90051-7 · Cited by 17
Álvarez-Estévez, D. (2012) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 14
Advantages of measuring air flow in the pharynx with internal thermistors
Akre, H., & Skatvedt, O. (2000) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050050233 · Cited by 12
Automatic unsupervised respiratory analysis of infant respiratory inductance plethysmography signals
Robles-Rubio, C. A., Kearney, R. E., Bertolizio, G., & Brown, K. A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238402 · Cited by 11
Respiratory Monitoring in Sleep Apnea Syndrome
Levy, P. A., Pépin, J., Wuyam, B., & Veale, D. (1992) · SLEEP · doi:10.1093/sleep/15.suppl_6.s5 · Cited by 11
Zhang, X., Landsness, E. C., Miao, H., Chen, W., Tang, M., Brier, L. M., Culver, J. P., Lee, J., & Anastasio, M. A. (2024) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2024.110250 · Cited by 10
Sleep-Related Breathing Disorders in the Elderly
Stone, K. L., & Redline, S. S. (2006) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2006.04.003 · Cited by 8
Appropriate Statistics for Interrater Reliability in Sleep Studies
KRAEMER, H. C., Bliwise, N. G., & Bliwise, D. L. (1991) · SLEEP · doi:10.1093/sleep/14.1.89 · Cited by 8
Self-citationTracing air flow and diagnosing hypopnoeas in normal subjects
Akre, H., Borgersen, A. K., Mair, I. W. S., & Skatvedt, O. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/302 · Cited by 7
Optimal Classification of Respiratory Patterns From Manual Analyses Using Expectation-Maximization
Robles-Rubio, C. A., Brown, K. A., & Kearney, R. E. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2741501 · Cited by 7
Nigro, C. A., Malnis, S., Dibur, E., & Rhodius, E. E. (2011) · Sleep And Breathing · doi:10.1007/s11325-011-0524-y · Cited by 7
The use of epochs to stage sleep results in incorrect computer-generated AHI values
Norman, M. B., Middleton, S., & Sullivan, C. E. (2010) · Sleep And Breathing · doi:10.1007/s11325-010-0344-5 · Cited by 7
Measurement of inter‐rater agreement for transient events using Monte Carlo sampled permutations
Norman, R. G., & Scott, M. A. (2006) · Statistics in Medicine · doi:10.1002/sim.2568 · Cited by 6
Bredenbröker, D., Brandenburg, U., Penzel, T., Peter, J. H., & von Wichert, P. (1998) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1007/s11818-998-0018-8 · Cited by 5
Nino‐Murcia, G., Bliwise, D. L., Keenan, S. A., & Dement, W. C. (1987) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462300001240 · Cited by 4
Self-citationDiagnosis of sleep-disordered breathing in chronic heart failure
Ward, N. R. (2011) · Spiral (Imperial College London) · doi:10.25560/9597 · Cited by 3
Diagnostic Tests for Sleep Disorders
Altalag, A., ROAD, J. D., & Wilcox, P. (2009) · Springer eBooks · doi:10.1007/978-1-84882-231-3_10 · Cited by 3
Classification and Characterization of Sleep Apnea using Machine Learning Methods on Sleep Studies
Zhang, L. (2021) · Cited by 1
Diagnostic Tests for Sleep Disorders
Altalag, A., ROAD, J. D., Wilcox, P., & Aboulhosn, K. (2018) · In clinical practice · doi:10.1007/978-3-319-93650-5_10
Hurry, M. J. (1998) · Louisiana State University · doi:10.31390/gradschool_disstheses.6783
Machine learning for time-series analysis in health care
Steenkiste, T. V. (2020) · Ghent University Academic Bibliography (Ghent University)
Consideraciones sobre la carta editorial: "Hasta cuándo poligrafía respiratoria vs. polisomnografía"
Nigro, C. A. (2013) · Revista americana de medicina respiratoria
Computer-aided analysis of infant respiratory patterns
Robles-Rubio, C. A. (2016) · doi:10.82308/47304
Metadata
- Authors
- Bliwise, D., Bliwise, N. G., Kraemer, H. C., & Dement, W.
- Affiliations
- Stanford Medicine (US)
- Corresponding author
- Bliwise, Donald
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1984-11
- Volume
- 12
- Issue
- 1
- Pages
- 49-56
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2033855064
- Semantic Scholar
- 3fdfaeadf304bc7794397e6f5243253b71a820d1
- Cited by
- 52
- References
- 10
- Citations by year
- 2024: 1 · 2023: 1 · 2022: 2 · 2021: 5 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 1 · 2015: 2 · 2013: 3
- FWCI
- 3.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute on Aging
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Keywords
- measurement error, visual grading, sleep stage classification, respiratory disturbances, sleep apnea, inter-rater reliability, recording quality
- MeSH terms
- Aged, Electrophysiology, Female, Humans, Male, Middle Aged, Neurophysiology, Respiration, Sleep
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.