Characterization of polymer electrolytes for fuel cell applications
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A number of empirical sorption isotherms have been established experimentally based on measurements on Nafion 1100.
“A number of empirical sorption isotherms have been established experimentally based on measurements on Nafion 1100 [39,51,52,53,54].”
From Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review (2020) · cites this paper as [53]
Rigorous measurement of proton conductivity, water diffusivity, and electroosmotic drag coefficient for Nafion 1100 was initiated in the early 1990s in works by Zawodzinski et al. and Fuller and Newman.
“The rigorous measurement of these properties for Nafion 1100 was initiated in the early 1990s in a series of works by Zawodzinski et al. [52,53,79,80] and Fuller and Newman [81].”
From Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review (2020) · cites this paper as [53]
In works using the Springer model, parameterisation of the membrane properties is exclusively drawn from four experimental works, all dating to 1998 and earlier, and all measured on Nafion 117.
“In works using the Springer model, parameterisation of the membrane properties is exclusively drawn from four experimental works [39,52,53,87], all dating to 1998 and earlier, and all measured on Nafion 117.”
From Modelling the Proton-Conductive Membrane in Practical Polymer Electrolyte Membrane Fuel Cell (PEMFC) Simulation: A Review (2020) · cites this paper as [53]
The citation lists haven’t been fetched yet
References 20 · Cited by 378
- Authors
- ZAWODZINSKIJR, T., SPRINGER, T., URIBE, F., & GOTTESFELD, S.
- Affiliations
- Los Alamos National Laboratory (US)
- Venue
- Solid State Ionics
- Publisher
- Elsevier BV
- Published
- 1993-03
- Volume
- 60
- Issue
- 1-3
- Pages
- 199-211
- ISSN
- 0167-2738 (ISSN-L)
- OpenAlex
- W2091166494
- Cited by
- 378
- References
- 20
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 10 · 2023: 9 · 2022: 9 · 2021: 10 · 2020: 7 · 2019: 10 · 2018: 8 · 2017: 8 · 2016: 7 · 2015: 18 · 2014: 12 · 2013: 13 · 2012: 15
- FWCI
- 6.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Solid State Ionics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Fuel Cells and Related Materials
- Physical Sciences › Materials Science › Materials Chemistry › Advancements in Solid Oxide Fuel Cells
- Physical Sciences › Engineering › Mechanical Engineering › Membrane Separation and Gas Transport
- Keywords
- proton exchange membrane fuel cells, perfluorosulfonic acid membranes, Nafion, membrane hydration, water sorption, ionic conductivity, diffusion coefficient, hydrophobicity, contact angle, water distribution modeling, membrane thickness, membrane transport
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review