Open-endcap Penning traps for high precision experiments
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“an end cap three times longer than the inner radius suffices for minimizing deviations (below 1%) of the trap's electrical properties calculated with equation (13) compared with those calculated with an infinitely long open end cap.”
From Calculation of electrostatic fields using quasi-Green's functions: application to the hybrid Penning trap (2008) · cites this paper as [33]
Citations
Cites
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Self-citationNew high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Antihydrogen production using trapped plasmas
Gabrielse, G., Rolston, S. L., Haarsma, L., & Kells, W. (1988) · Physics Letters A · doi:10.1016/0375-9601(88)90470-7 · Cited by 244
Self-citationFirst Capture of Antiprotons in a Penning Trap: A Kiloelectronvolt Source
Gabrielse, G., Fei, X., Helmerson, K., Rolston, S. L., Tjoelker, R. L., TRAINOR, T. A., Kalinowsky, H., Haas, J., & Kells, W. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.2504 · Cited by 199
Self-citationCylindrical Penning traps with orthogonalized anharmonicity compensation
Gabrielse, G., & Mackintosh, F. C. (1984) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(84)85061-2 · Cited by 167
Self-citationObservation of a Relativistic, Bistable Hysteresis in the Cyclotron Motion of a Single Electron
Gabrielse, G., Dehmelt, H., & Kells, W. (1985) · Physical Review Letters · doi:10.1103/physrevlett.54.537 · Cited by 148
Self-citationPure Electron Plasma, Liquid, and Crystal
Malmberg, J. H., & O’Neil, T. M. (1977) · Physical Review Letters · doi:10.1103/physrevlett.39.1333 · Cited by 147
Gabrielse, G. (1983) · Physical Review A · doi:10.1103/physreva.27.2277 · Cited by 97
Self-citationHigh mass resolution with a new variable anharmonicity Penning trap
Van Dyck, R. S., Wineland, D. J., Ekstrom, P. A., & Dehmelt, H. G. (1976) · Applied Physics Letters · doi:10.1063/1.88793 · Cited by 87
New measurement of the proton-electron mass ratio
Dyck, R. S. V., Moore, F. L., Farnham, D. L., & Schwinberg, P. B. (1985) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(85)80006-9 · Cited by 86
Research works printed but not linked: 1
- Tan, 1988, Bull. Am. Phys. Soc., 33, 931
Cited by
Items 101–200 of 288
Römpp, A., Barbu, I., Mihalca, R., Duursma, M. C., Mize, T. H., McDonnell, L. A., & Heeren, R. M. A. (2005) · European Journal of Mass Spectrometry · doi:10.1255/ejms.732 · Cited by 31
Image charge forces inside conducting boundaries
Tinkle, M. D., & Barlow, S. E. (2001) · Journal of Applied Physics · doi:10.1063/1.1383016 · Cited by 29
Measurement of Charge Exchange between H2 and Low-Energy Ions with Charge States 35≤q≤80
Beck, B. R., Steiger, J., Weinberg, G., Church, D. A., McDonald, J. W., & Schneider, D. H. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.1735 · Cited by 27
Resistive and sympathetic cooling of highly-charged-ion clouds in a Penning trap
Vogel, M., Häffner, H., Hermanspahn, K., Stahl, S., Steinmann, J., & Quint, W. (2014) · Physical Review A · doi:10.1103/physreva.90.043412 · Cited by 26
Weisbrod, C. R., Kaiser, N. K., Skulason, G. E., & Bruce, J. E. (2008) · Analytical Chemistry · doi:10.1021/ac800535e · Cited by 28
Single electron relativistic clock interferometer
Bushev, P. A., Cole, J. H., Sholokhov, D., Kukharchyk, N., & Zych, M. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/9/093050 · Cited by 39
Continuous Stern–Gerlach Effect on Atomic Ions
Werth, G., Häffner, H., & Quint, W. (2002) · Advances in atomic, molecular, and optical physics · doi:10.1016/s1049-250x(02)80009-x · Cited by 27
“The potential F inside this configuration can be described in cylindrical coordinates r, z,ö by an expansion in Legendre polynomials Pi: F(r,ö) = U0 2 ∞∑ i = 0 Ci ( r d )i Pi(cosö), (7) where d2 = ( z20 + r 2 0 /2 ) /2 is a characteristic dimension of the trap (Gabrielse et al., 1989).”
Antihydrogen production and precision experiments
Holzscheiter, M. H., Bendiscioli, G., Bertin, A., Bollen, G., Bruschi, M., Cesar, C. L., Charlton, M., Corradini, M., Depedis, D., Doser, M., et al. (1997) · Nuclear Physics B - Proceedings Supplements · doi:10.1016/s0920-5632(97)00296-x · Cited by 25
Direct Measurement of the Free Cyclotron Frequency of a Single Particle in a Penning Trap
Ulmer, S., Blaum, K., Kracke, H., Mooser, A. H., Quint, W., Rodegheri, C. C., & Walz, J. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.103002 · Cited by 33
Tracking the Magnetron Motion in FT-ICR Mass Spectrometry
Jertz, R., Friedrich, J., Kriete, C., Николаев, Е. Н., & Baykut, G. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1148-4 · Cited by 27
Trap-assisted precision spectroscopy of forbidden transitions in highly-charged ions
Vogel, M., & Quint, W. (2009) · Physics Reports · doi:10.1016/j.physrep.2009.12.007 · Cited by 30
Rapid crystallization of externally produced ions in a Penning trap
Murböck, T., Schmidt, S., Birkl, G., Nörtershäuser, W., Thompson, R. C., & Vogel, M. (2016) · Physical Review A · doi:10.1103/physreva.94.043410 · Cited by 22
Vartanian, V., Hadjarab, F., & Laude, D. A. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04314-4 · Cited by 23
“Linearizing” an ion cyclotron resonance cell
Barlow, S. E., & Tinkle, M. D. (2002) · Review of Scientific Instruments · doi:10.1063/1.1518787 · Cited by 23
Verdú, J., Kreim, S., Blaum, K., Kracke, H., Quint, W., Ulmer, S., & Walz, J. (2008) · New Journal of Physics · doi:10.1088/1367-2630/10/10/103009 · Cited by 22
“This issue has been investigated mathematically in [33]: an end cap three times longer than the inner radius suffices for minimizing deviations (below 1%) of the trap’s electrical properties calculated with equation (13) compared with those calculated with an infinitely long open end cap.”
BackgroundContinuous Stern–Gerlach effect and the magnetic moment of the antiproton
Quint, W., Alonso, J., Djekić, S., Kluge, H.-J., Stahl, S., Valenzuela, T., Verdú, J., Vogel, M., & Werth, G. (2004) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2003.08.008 · Cited by 22
Vartanian, V., & Laude, D. A. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04091-k · Cited by 22
A conceptual approach for FT-ICR cell harmonization utilizing external shim electrodes
Tolmachev, A. V., Robinson, E. W., Smith, R. D., Leach, F. E., Futrell, J. H., & Paša‐Tolić, L. (2012) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2012.06.027 · Cited by 22
Single electron relativistic clock interferometer
(20051517), P. B., Cole, J. H., (20051520), D. S., (20051523), N. K., & (20051526), M. Z. (2024) · Figshare · Cited by 21
Towards high precision in-trap laser spectroscopy of highly charged ions
Andjelkovic, Z., Bharadia, S., Sommer, B., Vogel, M., & Nörtershäuser, W. (2010) · Hyperfine Interactions · doi:10.1007/s10751-009-0155-x · Cited by 24
Simulated ion trajectory and induced signal in ion cyclotron resonance ion traps
Xiang, X., Guan, S., & Marshall, A. G. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85014-3 · Cited by 21
Self-Excitation and Feedback Cooling of an Isolated Proton
Guise, N. D., DiSciacca, J., & Gabrielse, G. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.143001 · Cited by 26
Self-citationImage charge shift in high-precision Penning traps
Schuh, M., Heiße, F., Eronen, T., Ketter, J., Köhler-Langes, F., Rau, S., Segal, T., Quint, W., Sturm, S., & Blaum, K. (2019) · Physical Review A · doi:10.1103/physreva.100.023411 · Cited by 24
The anomalous magnetic moment of the electron
Vogel, M. (2009) · Contemporary Physics · doi:10.1080/00107510902765239 · Cited by 22
“it depends on the square of the coordinates: where d is the characteristic trap dimension 72 , 74 .”
BackgroundSerrano, J., Palmeira, C. M., Wallace, K. B., & Kuehl, D. W. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(199611)10:14<1789::aid-rcm752>3.0.co;2-6 · Cited by 71
Jackson, G. S., Canterbury, J. D., Guan, S., & Marshall, A. G. (1997) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00232-2 · Cited by 19
Sympathetic cooling schemes for separately trapped ions coupled via image currents
Will, C., Bohman, M., Driscoll, T., Wiesinger, M., Abbass, F., Borchert, M. J., Devlin, J. A., Erlewein, S., Fleck, M., Latacz, B. M., et al. (2022) · New Journal of Physics · doi:10.1088/1367-2630/ac55b3 · Cited by 19
“usually created by a stack of five cylindrical electrodes in a compensated, orthogonal design [25].”
BackgroundCommissioning of the double Penning trap system MLLTRAP
Kolhinen, V. S., Bußmann, M., Gartzke, E., Habs, D., Neumayr, J. B., Schürmann, C., Szerypo, J., & Thirolf, P. G. (2008) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2008.12.004 · Cited by 18
An ultra-stable voltage source for precision Penning-trap experiments
Böhm, C., Sturm, S., Rischka, A., Dörr, A., Eliseev, S., Goncharov, M., Höcker, M., Ketter, J., Köhler, F., Marschall, D., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2016.05.044 · Cited by 23
Евгеньевич, Ф. В., & Zenobi, R. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00365-7 · Cited by 18
A 4.7 Tesla internal MALDI-FTICR instrument for high mass studies: performance and methods
Easterling, M. L., Pitsenberger, C. C., Kulkarni, S. S., Taylor, P. K., & Amster, I. J. (1996) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04403-5 · Cited by 18
Upgrades at ClusterTrap and latest results
Martinez, F., Bandelow, S., Breitenfeldt, C., Marx, G., Schweikhard, L., Vass, A., & Wienholtz, F. (2014) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2013.12.018 · Cited by 17
von Lindenfels, D., Brantjes, N. P. M., Birkl, G., Quint, W., Шабаев, В. М., & Vogel, M. (2011) · Canadian Journal of Physics · doi:10.1139/p10-071 · Cited by 31
In situ optimization of the electrode geometry of the quadrupole ion trap
Gill, L. A., Amy, J. W., Vaughn, W. E., & Cooks, R. G. (1999) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14283-5 · Cited by 22
Laser spectroscopy of hyperfine structure in highly charged ions: a test of QED at high fields
Winters, D., Vogel, M., Segal, D. M., Thompson, R. C., & Nörtershäuser, W. (2007) · Canadian Journal of Physics · doi:10.1139/p07-023 · Cited by 17
Vartanian, V., & Laude, D. A. (1994) · Organic Mass Spectrometry · doi:10.1002/oms.1210291120 · Cited by 18
High efficiency positron accumulation for high-precision magnetic moment experiments
Hoogerheide, S. F., Dorr, J. C., Novitski, E., & Gabrielse, G. (2015) · Review of Scientific Instruments · doi:10.1063/1.4919413 · Cited by 19
Self-citationAn optimized geometry for a micro Penning-trap mass spectrometer based on interconnected ions
Cornejo, J. M., Gutiérrez, M. J., Ruiz, E. M. G., Bautista-Salvador, A., Ospelkaus, C., Ståhl, S., & Rodríguez, D. (2016) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2016.10.010 · Cited by 16
Laser spectroscopy by a radiofrequency measurement on a single ion in a Penning trap
Vogel, M., & Quint, W. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/1/013024 · Cited by 17
A catching trapp for all antiproton seasons
Nieto, M. M., & Holzscheiter, M. H. (1995) · Applied Physics B · doi:10.1007/bf01135850 · Cited by 16
Aspects of fundamental physics in precision spectroscopy of highly charged ions in Penning traps
Vogel, M., & Quint, W. (2013) · Annalen der Physik · doi:10.1002/andp.201300032 · Cited by 20
Resolving an Individual One-Proton Spin Flip to Determine a Proton Spin State
DiSciacca, J., Marshall, M., Marable, K., & Gabrielse, G. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.140406 · Cited by 21
Self-citationSympathetic cooling in two-species ion crystals in a Penning trap
Schmidt, S., Murböck, T., Andelkovic, Z., Birkl, G., König, K., Nörtershäuser, W., Thompson, R. C., & Vogel, M. (2017) · Journal of Modern Optics · doi:10.1080/09500340.2017.1342877 · Cited by 19
Resistive cooling of highly charged ions in a Penning trap to a fluidlike state
Ebrahimi, M. S., Guo, Z. M., Vogel, M., Wiesel, M., Birkl, G., & Quint, W. (2018) · Physical Review A · doi:10.1103/physreva.98.023423 · Cited by 16
Electron Magnetic Moment in Highly Charged Ions: The ARTEMIS Experiment
Vogel, M., Ebrahimi, M. S., Guo, Z., Khodaparast, A., Birkl, G., & Quint, W. (2018) · Annalen der Physik · doi:10.1002/andp.201800211 · Cited by 15
(Anti)hydrogen recombination studies in a nested Penning trap
Quint, W., Kaiser, R., Hall, D. S., & Gabrielse, G. (1993) · Hyperfine Interactions · doi:10.1007/bf02316717 · Cited by 15
Self-citationCage, B., McFarland, M. A., Hendrickson, C. L., Dalal, N. S., & Marshall, A. G. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp021287k · Cited by 15
The magnetic moment of the antiproton
Quint, W., & Gabrielse, G. (1993) · Hyperfine Interactions · doi:10.1007/bf02316738 · Cited by 15
Self-citationA compact Penning trap for light ions
Gomer, V., Strauss, H., & Meschede, D. (1995) · Applied Physics B · doi:10.1007/bf01135848 · Cited by 15
Trapped Ion Oscillation Frequencies as Sensors for Spectroscopy
Vogel, M., Quint, W., & Nörtershäuser, W. (2010) · Sensors · doi:10.3390/s100302169 · Cited by 18
“The properties of such a trap are described in detail in [16].”
BackgroundMethodInfluentialExtremely cold antiprotons for antihydrogen production
Gabrielse, G., Jhe, W., Phillips, D. F., Quint, W., Tseng, C.-H., Haarsma, L., Abdullah, K., Gröbner, J., & Kalinowsky, H. (1993) · Hyperfine Interactions · doi:10.1007/bf02316708 · Cited by 14
Self-citationHighly excited electron cyclotron for QCD axion and dark-photon detection
Fan, X., Gabrielse, G., Graham, P. W., Ramani, H., Wong, S. S. Y., & Xiao, Y.-F. (2025) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.111.075022 · Cited by 24
“(2) The conversion field, and hence the conversion efficiency, can be left fixed at the largest possible value while the field of the one-electron quantum cyclotron is swept over the widest possible range of possible axion masses.”
InfluentialSelf-citationAperture method to determine the density and geometry of antiparticle plasmas
Oxley, P., Bowden, N. S., Parrott, R. E., Speck, A. J., Storry, C. H., Tan, J., Wessels, M., Gabrielse, G., Grzonka, D., Oelert, W., et al. (2004) · Physics Letters B · doi:10.1016/j.physletb.2004.04.084 · Cited by 12
Self-citationvon Lindenfels, D., Vogel, M., Quint, W., Birkl, G., & Wiesel, M. (2013) · Hyperfine Interactions · doi:10.1007/s10751-013-0961-z · Cited by 18
Precision Measurements of the Fundamental Properties of the Proton and Antiproton
Smorra, C., & Mooser, A. H. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1412/3/032001 · Cited by 19
“The coupling trap system consists of two orthogonal compensated Penning traps [78] where the electrodes in between the two ring electrodes transmit the image-current signal to couple protons to laser-cooled beryllium ions [47].”
BackgroundSecondary resonances in Penning traps. Non-lie symmetry algebras and quantum states
Karasev, M. V., & Novikova, E. M. (2013) · Russian Journal of Mathematical Physics · doi:10.1134/s1061920813030047 · Cited by 12
“The micro- and nano-Penning traps applied, for instance, in fine detectors [1–5] and artificial “atoms” [6] are of special interest.”
Evaluation of major historical ICR cell designs using electric field simulations
Николаев, Е. Н., & Lioznov, A. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21671 · Cited by 12
“This made the trap much more useful for high‐precision mass measurement experiments (Gabrielse et al., 1989).”
BackgroundInfluentialCharacterization of a new open cylindrical ion cyclotron resonance cell with unusual geometry
Kanawati, B., & Wanczek, K. P. (2007) · Review of Scientific Instruments · doi:10.1063/1.2751100 · Cited by 13
Vartanian, V., & Laude, D. A. (1998) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(98)14121-0 · Cited by 13
Antihydrogen production and precision experiments. The ATHENA collaboration
Holzscheiter, M. H., Bendiscioli, G., Bertin, A., Bollen, G., Bruschi, M., Cesar, C. L., Charlton, M., Corradini, M., Depedis, D., Doser, M., et al. (1997) · Hyperfine Interactions · doi:10.1023/a:1012628711418 · Cited by 13
Optimized planar Penning traps for quantum information studies
Goldman, J., & Gabrielse, G. (2011) · Hyperfine Interactions · doi:10.1007/s10751-011-0323-7 · Cited by 11
Self-citationTrap-assisted precision spectroscopy of highly charged ions
Vogel, M., & Quint, W. (2009) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/42/15/154016 · Cited by 11
Modes of spheroidal ion plasmas at the Brillouin limit
Tinkle, M. D., Greaves, R. G., & Surko, C. M. (1996) · Physics of Plasmas · doi:10.1063/1.871809 · Cited by 11
Fei, X., & Snow, W. M. (1999) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(98)01434-x · Cited by 14
Weisbrod, C. R., Kaiser, N. K., Skulason, G. E., & Bruce, J. E. (2010) · Analytical Chemistry · doi:10.1021/ac100461c · Cited by 14
O’Connor, P. B. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.685 · Cited by 11
A single trapped antiproton and antiprotons for antihydrogen production
Gabrielse, G., Jhe, W., Phillips, D. F., Quint, W., Haarsma, L., Abdullah, K., Kalinowsky, H., & Gr�bner, J. (1993) · Hyperfine Interactions · doi:10.1007/bf00567246 · Cited by 11
Self-citationExperiments with Highly-Ionized Atoms in Unitary Penning Traps
Hoogerheide, S. F., Naing, A., Dreiling, J., Brewer, S. M., Guise, N. D., & Tan, J. N. (2015) · Atoms · doi:10.3390/atoms3030367 · Cited by 12
Optically transparent solid electrodes for precision Penning traps
Wiesel, M., Birkl, G., Ebrahimi, M. S., Martin, A., Quint, W., Stallkamp, N., & Vogel, M. (2017) · Review of Scientific Instruments · doi:10.1063/1.5002180 · Cited by 12
TAMUTRAP facility: Penning trap facility for weak interaction studies
Shidling, P. D., Kolhinen, V. S., Schroeder, B., Morgan, N., Özmetin, A., & Melconian, D. (2019) · Hyperfine Interactions · doi:10.1007/s10751-019-1584-9 · Cited by 10
“[14] a full solution for the electric field of such a trap was derived without implementing the longendcap approximation.”
MethodUsing electric fields to prevent mirror-trapped antiprotons in antihydrogen studies
Richerme, P., Gabrielse, G., Malbrunot-Ettenauer, S., Kalra, R., Tardiff, E. R., Fitzakerley, D. W., George, M. C., Hessels, E. A., Storry, C. H., Weel, M., et al. (2013) · Physical Review A · doi:10.1103/physreva.87.023422 · Cited by 10
Self-citationCharacterization of a new open cylindrical ICR cell for ion–ion collision studies
Kanawati, B., & Wanczek, K. P. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2007.09.007 · Cited by 10
Vartanian, V., & Laude, D. A. (1996) · Analytical Chemistry · doi:10.1021/ac950787p · Cited by 10
Using a Penning trap to weigh antiprotons
Lagomarsino, V., Lia, V., Manuzio, G., & Testera, G. (1994) · Physical Review A · doi:10.1103/physreva.50.977 · Cited by 10
Coherent spectroscopy with a single antiproton spin
Latacz, B. M., Erlewein, S., Fleck, M., Jäger, J. I., Abbass, F., Arndt, B. P., Geissler, P., Imamura, T., Leonhardt, M., Micke, P., et al. (2025) · Nature · doi:10.1038/s41586-025-09323-1 · Cited by 15
“25, are primarily made out of gold-plated copper.”
Driver, J. A., Nagornov, K. O., Kozhinov, A. N., Tsybin, Y. O., Kharchenko, A., & Amster, I. J. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1817-6 · Cited by 9
“Analyzer cells with hyperbolically shaped electrodes produce a purely quadratic trapping potential, and have been employed by physicists who make high precision mass measurements of atomic species [9].”
BackgroundOptically transparent solid electrodes for precision Penning traps
Wiesel, M., Birkl, G., Ebrahimi, M. S., Martin, A., Quint, W., Stallkamp, N., & Vogel, M. (2017) · GSI Repository (German Federal Government) · Cited by 9
Weinberg, G., Beck, B. R., Steiger, J., Church, D. A., McDonald, J., & Schneider, D. H. (1998) · Physical Review A · doi:10.1103/physreva.57.4452 · Cited by 9
Vartanian, V., & Laude, D. A. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00327-a · Cited by 9
Jhe, W., Phillips, D. F., Haarsma, L., Tan, J., & Gabrielse, G. (1992) · Physica Scripta · doi:10.1088/0031-8949/46/3/009 · Cited by 12
Self-citationPlans for laser spectroscopy of trapped cold hydrogen-like HCI
Winters, D., Abdulla, A. M., Castrejón-Pita, J. R., de Lange, A., Segal, D. M., & Thompson, R. C. (2005) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2005.03.173 · Cited by 9
Resistive cooling of ions' center-of-mass energy in a Penning trap on millisecond time scales
Kiffer, M., Ringleb, S., Stöhlker, T., & Vogel, M. (2024) · Physical Review A · doi:10.1103/physreva.109.033102 · Cited by 8
Proton transport from the antimatter factory of CERN
Leonhardt, M., Schweitzer, D., Abbass, F., Anjum, K., Arndt, B. P., Erlewein, S., Endoh, S., Geissler, P., Imamura, T., Jäger, J. I., et al. (2025) · Nature · doi:10.1038/s41586-025-08926-y · Cited by 11
“The trap consists of a stack of cylindrical, gold-plated electrodes, made from oxygen-free high conductivity copper, engineered in compensated and orthogonal design 26 .”
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Smorra, C., Abbass, F., Schweitzer, D., Bohman, M., Devine, J., Dutheil, Y., Hobl, A., Arndt, B. P., Bauer, B. B., Devlin, J. A., et al. (2023) · Review of Scientific Instruments · doi:10.1063/5.0155492 · Cited by 15
PIPERADE: A double Penning trap for mass separation and mass spectrometry at DESIR/SPIRAL2
Ascher, P., Daudin, L., Flayol, M., Gerbaux, M., Grévy, S., Hukkanen, M., Husson, A., de Roubin, A., Alfaurt, P., Blank, Β., et al. (2021) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2021.165857 · Cited by 11
A brief history in time of ion traps and their achievements in science
Holzscheiter, M. H. (1995) · Physica Scripta · doi:10.1088/0031-8949/1995/t59/009 · Cited by 13
Precision measurements with non-laser-cooled trapped ions
Karr, J. (2009) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/42/15/154018 · Cited by 8
Calculation of the electrostatic potential field for an open-endcap cylindrical penning trap
Farrar, K. (2002) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(01)02110-6 · Cited by 10
Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a6006m · Cited by 8
First application of the phase-imaging ion-cyclotron resonance technique at TRIGA-Trap
Chenmarev, S., Nagy, S., van de Laar, J. J. W., Blaum, K., Block, M., & Düllmann, C. E. (2023) · The European Physical Journal A · doi:10.1140/epja/s10050-023-00935-7 · Cited by 7
“High-precision frequency measurements of trapped ions are made possible by elaborated trap designs [37] and careful trap-tuning.”
BackgroundHILITE—ions in intense photon fields
Ringleb, S., Vogel, M., Kumar, S., Quint, W., Paulus, G. G., & Stöhlker, T. (2015) · Physica Scripta · doi:10.1088/0031-8949/2015/t166/014067 · Cited by 10
Determination of analytic potentials from finite element computations
Barlow, S. E., TAYLOR, A. E. R., & Swanson, K. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00452-8 · Cited by 7
Charlton, M. (1997) · Hyperfine Interactions · doi:10.1023/a:1012669820504 · Cited by 7
Latacz, B. M., Fleck, M., Jäger, J. I., Umbrazunas, G., Arndt, B. P., Erlewein, S., Wursten, E., Devlin, J. A., Micke, P., Abbass, F., et al. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.053201 · Cited by 11
“Both traps are in cylindrical five-electrode geometry [20] with an inner electrode diameter of 3 .”
BackgroundExtreme-field physics in Penning traps: The ARTEMIS and HILITE experiments
Vogel, M., Birkl, G., Ebrahimi, M. S., von Lindenfels, D., Martin, A., Paulus, G. G., Quint, W., Ringleb, S., Stöhlker, T., & Wiesel, M. (2015) · Hyperfine Interactions · doi:10.1007/s10751-015-1173-5 · Cited by 9
Reza, A., Banerjee, K., Das, P., Ray, K., Bandyopadhyay, S., & Dam, B. (2017) · Review of Scientific Instruments · doi:10.1063/1.4978799 · Cited by 6
A PERSPECTIVE ON PERSONAL CONTRIBUTIONS TO FT‐ICR MASS SPECTROMETRY
Gross, M. L., & Rempel, D. L. (2020) · Mass Spectrometry Reviews · doi:10.1002/mas.21657 · Cited by 5
The Magnetic Moments of the Proton and the Antiproton
Ulmer, S., & Smorra, C. (2014) · Springer tracts in modern physics · doi:10.1007/978-3-642-45201-7_5 · Cited by 7
Magnetic Moment of the Bound Electron
Vogel, M., & Quint, W. (2014) · Springer tracts in modern physics · doi:10.1007/978-3-642-45201-7_3 · Cited by 7
Николаев, Е. Н., Vladimirov, G., & Boldin, I. A. (2013) · AIP conference proceedings · doi:10.1063/1.4796085 · Cited by 5
Metadata
- Authors
- Gabrielse, G., Haarsma, L., & Rolston, S. L.
- Affiliations
- Harvard University (US)
- Venue
- International Journal of Mass Spectrometry and Ion Processes
- Publisher
- Elsevier BV
- Published
- 1989-04
- Volume
- 88
- Issue
- 2-3
- Pages
- 319-332
- ISSN
- 0168-1176 (ISSN-L)
- OpenAlex
- W1979044941
- Semantic Scholar
- 9cb4e78bc7ef4b434673d831e0ff9f38d84c1027
- Cited by
- 288
- References
- 15
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 12 · 2023: 5 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 9 · 2018: 9 · 2017: 15 · 2016: 4 · 2015: 15 · 2014: 11 · 2013: 18 · 2012: 14
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- International Journal of Mass Spectrometry and Ion Processes (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- Penning trap, cylindrical trap, antiproton cooling, antihydrogen production, anharmonicity, electrode gap
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.