Open-endcap Penning traps for high precision experiments
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“an end cap three times longer than the inner radius suffices for minimizing deviations (below 1%) of the trap's electrical properties calculated with equation (13) compared with those calculated with an infinitely long open end cap.”
From Calculation of electrostatic fields using quasi-Green's functions: application to the hybrid Penning trap (2008) · cites this paper as [33]
Citations
Cites
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Self-citationNew high-precision comparison of electron and positron g factors
Van Dyck, R. S., Schwinberg, P. B., & Dehmelt, H. G. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.26 · Cited by 659
Antihydrogen production using trapped plasmas
Gabrielse, G., Rolston, S. L., Haarsma, L., & Kells, W. (1988) · Physics Letters A · doi:10.1016/0375-9601(88)90470-7 · Cited by 244
Self-citationFirst Capture of Antiprotons in a Penning Trap: A Kiloelectronvolt Source
Gabrielse, G., Fei, X., Helmerson, K., Rolston, S. L., Tjoelker, R. L., TRAINOR, T. A., Kalinowsky, H., Haas, J., & Kells, W. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.2504 · Cited by 199
Self-citationCylindrical Penning traps with orthogonalized anharmonicity compensation
Gabrielse, G., & Mackintosh, F. C. (1984) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(84)85061-2 · Cited by 167
Self-citationObservation of a Relativistic, Bistable Hysteresis in the Cyclotron Motion of a Single Electron
Gabrielse, G., Dehmelt, H., & Kells, W. (1985) · Physical Review Letters · doi:10.1103/physrevlett.54.537 · Cited by 148
Self-citationPure Electron Plasma, Liquid, and Crystal
Malmberg, J. H., & O’Neil, T. M. (1977) · Physical Review Letters · doi:10.1103/physrevlett.39.1333 · Cited by 147
Gabrielse, G. (1983) · Physical Review A · doi:10.1103/physreva.27.2277 · Cited by 97
Self-citationHigh mass resolution with a new variable anharmonicity Penning trap
Van Dyck, R. S., Wineland, D. J., Ekstrom, P. A., & Dehmelt, H. G. (1976) · Applied Physics Letters · doi:10.1063/1.88793 · Cited by 87
New measurement of the proton-electron mass ratio
Dyck, R. S. V., Moore, F. L., Farnham, D. L., & Schwinberg, P. B. (1985) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(85)80006-9 · Cited by 86
Research works printed but not linked: 1
- Tan, 1988, Bull. Am. Phys. Soc., 33, 931
Cited by
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Precision Mass Spectroscopy of the Antiproton and Proton Using Simultaneously Trapped Particles
Gabrielse, G., Khabbaz, A., Hall, D. S., Heimann, C., Kalinowsky, H., & Jhe, W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3198 · Cited by 404
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Thousandfold improvement in the measured antiproton mass
Gabrielse, G., Fei, X., Orozco, L., Tjoelker, R., Haas, J., Kalinowsky, H., Trainor, T., & Kells, W. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.1317 · Cited by 275
Self-citationPlasma and trap-based techniques for science with positrons
Danielson, J. R., Dubin, D. H. E., Greaves, R. G., & Surko, C. M. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.247 · Cited by 254
Cooling and slowing of trapped antiprotons below 100 meV
Gabrielse, G., Fei, X., Orozco, L. A., Tjoelker, R. L., Haas, J., Kalinowsky, H., Trainor, T. A., & Kells, W. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.1360 · Cited by 230
Self-citationFourier transform ion cyclotron resonance (FT ICR) mass spectrometry: Theory and simulations
Nikolaev, E. N., Kostyukevich, Y. I., & Vladimirov, G. N. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21422 · Cited by 201
Fourier transform ion cyclotron resonance detection: principles and experimental configurations
Marshall, A. G., & Hendrickson, C. L. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00588-7 · Cited by 196
JYFLTRAP: a cylindrical Penning trap for isobaric beam purification at IGISOL
Kolhinen, V. S., Kopecky, S., Eronen, T., Hager, U., Hakala, J., Huikari, J., Jokinen, A., Nieminen, A., Rinta-Antila, S., Szerypo, J., et al. (2004) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2004.05.029 · Cited by 186
Emerging science and technology of antimatter plasmas and trap-based beams
Surko, C. M., & Greaves, R. G. (2004) · Physics of Plasmas · doi:10.1063/1.1651487 · Cited by 184
Nikolaev, E. N., Boldin, I. A., Jertz, R., & Baykut, G. (2011) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-011-0125-9 · Cited by 164
“implemented this approach by inserting compensation rings into an open cylindrical cell [3] between the center section and the trapping sections so that it became a five-section compensated cell.”
MethodEffect of Experimental Parameters on the ESI FT-ICR Mass Spectrum of Fulvic Acid
Brown, T. L., & Rice, J. A. (2000) · Analytical Chemistry · doi:10.1021/ac9902087 · Cited by 160
JYFLTRAP: a Penning trap for precision mass spectroscopy and isobaric purification
Eronen, T., Kolhinen, V. S., Elomaa, V. V., Gorelov, D., Hager, U., Hakala, J., Jokinen, A., Kankainen, A., Karvonen, P., Kopecky, S., et al. (2012) · The European Physical Journal A · doi:10.1140/epja/i2012-12046-1 · Cited by 159
A Quadrupole Ion Trap with Cylindrical Geometry Operated in the Mass-Selective Instability Mode
Wells, J. M., Badman, E. R., & Cooks, R. G. (1998) · Analytical Chemistry · doi:10.1021/ac971198h · Cited by 170
A parts-per-billion measurement of the antiproton magnetic moment
Smorra, C., Sellner, S., Borchert, M. J., Harrington, J. A., Higuchi, T., Nagahama, H., Tanaka, T., Mooser, A., Schneider, G., Bohman, M., et al. (2017) · Nature · doi:10.1038/nature24048 · Cited by 149
Fievre, A., Solouki, T., Marshall, A. G., & Cooper, W. (1997) · Energy & Fuels · doi:10.1021/ef970005q · Cited by 148
High-precision comparison of the antiproton-to-proton charge-to-mass ratio
Ulmer, S., Smorra, C., Mooser, A., Franke, K., Nagahama, H., Schneider, G., Higuchi, T., Van Gorp, S., Blaum, K., Matsuda, Y., et al. (2015) · Nature · doi:10.1038/nature14861 · Cited by 147
Raimbault-Hartmann, H., Beck, D., Bollen, G., König, M., Kluge, H. J., Schark, E., Stein, J., Schwarz, S., & Szerypo, J. (1997) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(96)01067-1 · Cited by 142
Fourier transform ion cyclotron resonance mass spectrometry: technique developments
Marshall, A. G., & Schweikhard, L. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)85058-8 · Cited by 170
Weber, C., Elomaa, V.-V., Ferrer, R., Fröhlich, C., Ackermann, D., Aysto, J. H., Audi, G., Batist, L. H., Blaum, K., Block, M., et al. (2008) · Physical Review C · doi:10.1103/physrevc.78.054310 · Cited by 154
Boldin, I. A., & Nikolaev, E. N. (2011) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4838 · Cited by 128
Guan, S., & Marshall, A. G. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04190-v · Cited by 134
Double-trap measurement of the proton magnetic moment at 0.3 parts per billion precision
Schneider, G. L., Mooser, A. H., Bohman, M., Schön, N., Harrington, J. A., Higuchi, T., Nagahama, H., Sellner, S., Smorra, C., Blaum, K., et al. (2017) · Science · doi:10.1126/science.aan0207 · Cited by 158
Observation of the continuous Stern-Gerlach effect on an electron bound in an atomic Ion
Hermanspahn, N., Häffner, H., Kluge, H.-J., Quint, W., Stahl, S., Verdú, J., & Werth, G. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.427 · Cited by 113
Antimatter plasmas and antihydrogen
Greaves, R. G., & Surko, C. M. (1997) · Physics of Plasmas · doi:10.1063/1.872284 · Cited by 112
Kaiser, N. K., Savory, J. J., McKenna, A. M., Quinn, J. P., Hendrickson, C. L., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac201546d · Cited by 107
Trapped-ion cell with improved dc potential harmonicity for FT-ICR MS
Tolmachev, A. V., Robinson, E. W., Wu, S., Kang, H., Lourette, N. M., Paša-Tolić, L., & Smith, R. D. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.01.006 · Cited by 108
“Their study demonstrated that by adding the compensation electrodes to the open cylindrical cell, anharmonicities of the trapping potential could be tuned out, thus enabling the high precision measurements [17].”
BackgroundBeu, S. C., & Laude, D. A. (1992) · Analytical Chemistry · doi:10.1021/ac00026a016 · Cited by 120
Open trapped ion cell geometries for Fourier transform ion cyclotron resonance mass spectrometry
Beu, S. C., & Laude, D. A. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)80006-m · Cited by 117
Holzscheiter, M. H., & Charlton, M. (1999) · Reports on Progress in Physics · doi:10.1088/0034-4885/62/1/001 · Cited by 108
Electron Cooling of Protons in a Nested Penning Trap
Hall, D. S., & Gabrielse, G. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.1962 · Cited by 96
Self-citationOne-Particle Measurement of the Antiproton Magnetic Moment
DiSciacca, J., Marshall, M., Marable, K., Gabrielse, G., Ettenauer, S., Tardiff, E., Kalra, R., Fitzakerley, D. W., George, M. C., Hessels, E. A., et al. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.130801 · Cited by 90
Self-citationGabrielse, G., Phillips, D., Quint, W., Kalinowsky, H., Rouleau, G., & Jhe, W. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3544 · Cited by 91
Self-citationRepp, J., Böhm, C., López-Urrutia, J. R. C., Dörr, A., Eliseev, S., George, S., Goncharov, M., Novikov, Y. N., Roux, C., Sturm, S., et al. (2012) · Applied Physics B · doi:10.1007/s00340-011-4823-6 · Cited by 117
Observation of spin flips with a single trapped proton
Ulmer, S., Rodegheri, C. C., Blaum, K., Kracke, H., Mooser, A., Quint, W., & Walz, J. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.253001 · Cited by 89
Tank circuit model applied to particles in a Penning trap
Feng, X., Charlton, M., Holzscheiter, M., Lewis, R. A., & Yamazaki, Y. (1996) · Journal of Applied Physics · doi:10.1063/1.360947 · Cited by 87
March, R. E. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)85059-9 · Cited by 86
The route to ultra-low energy antihydrogen
Holzscheiter, M. H., Charlton, M., & Nieto, M. M. (2004) · Physics Reports · doi:10.1016/j.physrep.2004.08.002 · Cited by 109
A 16-parts-per-trillion measurement of the antiproton-to-proton charge–mass ratio
Borchert, M. J., Devlin, J. A., Erlewein, S., Fleck, M., Harrington, J. A., Higuchi, T., Latacz, B. M., Voelksen, F., Wursten, E., Abbass, F., et al. (2022) · Nature · doi:10.1038/s41586-021-04203-w · Cited by 127
BASE – The Baryon Antibaryon Symmetry Experiment
Smorra, C., Blaum, K., Bojtar, L., Borchert, M., Franke, K. A., Higuchi, T., Leefer, N., Nagahama, H., Matsuda, Y., Mooser, A., et al. (2015) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2015-02607-4 · Cited by 82
Nesterenko, D. A., Eronen, T., Kankainen, A., Cañete, L., Jokinen, A., Moore, I. D., Penttil�, H., RINTA-ANTILA, S., de Roubin, A., & Vilén, M. (2018) · The European Physical Journal A · doi:10.1140/epja/i2018-12589-y · Cited by 83
Atoms made entirely of antimatter: Two methods produce slow antihydrogen
Gabrielse, G. (2005) · Advances in atomic, molecular, and optical physics · doi:10.1016/s1049-250x(05)80009-6 · Cited by 87
Self-citationMass Spectrometry: Recent Advances and Future Directions
Bowers, M. T., Marshall, A. G., & McLafferty, F. W. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp960154u · Cited by 80
The LEBIT 9.4 T Penning trap mass spectrometer
Ringle, R., Bollen, G., Prinke, A. M., Savory, J., Schury, P., Schwarz, S., & Sun, T. (2009) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2009.03.207 · Cited by 78
von Lindenfels, D., Wiesel, M., Glazov, D. A., Volotka, A. V., Sokolov, M. M., Шабаев, В. М., Plunien, G., Quint, W., Birkl, G., Martin, A., et al. (2013) · Physical Review A · doi:10.1103/physreva.87.023412 · Cited by 74
Ion traps in modern mass spectrometry
Nolting, D., Malek, R., & Makarov, A. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21549 · Cited by 90
Estrada, J., Roach, T., Tan, J., Yesley, P., & Gabrielse, G. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.859 · Cited by 71
Self-citationThe electron mass from g -factor measurements on hydrogen-like carbon 12 C 5+
Köhler, F., Sturm, S., Kracke, A., Werth, G., Quint, W., & Blaum, K. (2015) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/48/14/144032 · Cited by 74
Physics at CERN’s Antiproton Decelerator
Hori, M., & Walz, J. (2013) · Progress in Particle and Nuclear Physics · doi:10.1016/j.ppnp.2013.02.004 · Cited by 99
Current Perspectives on the Physics of Trapped Ions
Blatt, R., Gill, P., & Thompson, R. C. (1992) · Journal of Modern Optics · doi:10.1080/09500349214550221 · Cited by 80
Holzscheiter, M. H., Feng, X., Goldman, T., King, N. S. P., Lewis, R., Nieto, M. M., & Smith, G. A. (1996) · Physics Letters A · doi:10.1016/0375-9601(96)00189-2 · Cited by 67
Mass Resolution and Mass Accuracy: How Much Is Enough?
Marshall, A. G., Blakney, G. T., Chen, T., Kaiser, N. K., Mckenna, A. M., Rodgers, R. P., Ruddy, B. M., & Xian, F. (2013) · Mass Spectrometry · doi:10.5702/massspectrometry.s0009 · Cited by 66
Thompson, R. C. (1993) · Advances in atomic, molecular, and optical physics · doi:10.1016/s1049-250x(08)60088-9 · Cited by 64
Ketter, J., Eronen, T., Höcker, M., Streubel, S., & Blaum, K. (2013) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2013.10.005 · Cited by 80
“2Note that there is some disaccord about whether to normalize coefficients with η odd to the characteristic trap dimension d or to the distance from the center of the trap to the endcap electrode [16, 17, 37].”
BackgroundResolution of Single Spin Flips of a Single Proton
Mooser, A. H., Kracke, H., Blaum, K., Bräuninger, S. A., Franke, K., Leiteritz, C., Quint, W., Rodegheri, C. C., Ulmer, S., & Walz, J. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.140405 · Cited by 65
Experimental g factor of hydrogenlike silicon-28
Schabinger, B., Sturm, S., Wagner, A., Alonso, J., Quint, W., Werth, G., & Blaum, K. (2012) · The European Physical Journal D · doi:10.1140/epjd/e2012-20610-y · Cited by 59
The ingredients of cold antihydrogen: Simultaneous confinement of antiprotons and positrons at 4 K
Gabrielse, G., Hall, D. S., Roach, T., Yesley, P., Khabbaz, A., Estrada, J., Heimann, C., & Kalinowsky, H. (1999) · Physics Letters B · doi:10.1016/s0370-2693(99)00453-0 · Cited by 57
Self-citationThe quality factor of a superconducting rf resonator in a magnetic field
Ulmer, S., Kracke, H., Blaum, K., Kreim, S., Mooser, A., Quint, W., Rodegheri, C. C., & Walz, J. (2009) · Review of Scientific Instruments · doi:10.1063/1.3271537 · Cited by 56
Direct Measurement of the Proton Magnetic Moment
DiSciacca, J., & Gabrielse, G. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.153001 · Cited by 56
Self-citationSixfold improved single particle measurement of the magnetic moment of the antiproton
Nagahama, H., Smorra, C., Sellner, S., Harrington, J. A., Higuchi, T., Borchert, M. J., Tanaka, T., Besirli, M., Mooser, A. H., Schneider, G. L., et al. (2017) · Nature Communications · doi:10.1038/ncomms14084 · Cited by 69
Improved limit on the directly measured antiproton lifetime
Sellner, S., Besirli, M., Bohman, M., Borchert, M. J., Harrington, J., Higuchi, T., Mooser, A. H., Nagahama, H., Schneider, G. L., Smorra, C., et al. (2017) · New Journal of Physics · doi:10.1088/1367-2630/aa7e73 · Cited by 55
Solouki, T., Reinhold, B. B., Costello, C. E., O'Malley, M., Guan, S., & Marshall, A. G. (1998) · Analytical Chemistry · doi:10.1021/ac970562+ · Cited by 54
Comparing the antiproton and proton, and opening the way to cold antihydrogen
Gabrielse, G. (2001) · Advances in atomic, molecular, and optical physics · doi:10.1016/s1049-250x(01)80037-9 · Cited by 54
Self-citationPhysics at CERN's Antiproton Decelerator
Hori, M., & Walz, J. (2013) · MPG.PuRe (Max Planck Society) · Cited by 54
Kostyukevich, Y. I., Vladimirov, G. N., & Nikolaev, E. N. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0480-1 · Cited by 49
“The configuration of the electric field inside the ion trap strongly influences the analytical characteristics of the ICRmass spectrometer, its resolving power and mass accuracy [7, 8].”
BackgroundStability of a Charged Particle in a Combined Penning-Ioffe Trap
Squires, T. M., Yesley, P., & Gabrielse, G. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.5266 · Cited by 49
Self-citationFT-ICR MS optimization for the analysis of intact proteins
Tolmachev, A. V., Robinson, E. W., Wu, S., Paša-Tolić, L., & Smith, R. D. (2009) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2008.10.010 · Cited by 48
“Briefly, the compensated [15] cylindrical cell [16,17] used for the experiments reported here has additional trapping electrode segments to generate an electric field for ion confinement which is significantly closer to the ideal harmonic trapping potential [18].”
MethodAndelkovic, Z., Cazan, R., Nörtershäuser, W., Bharadia, S., Segal, D. M., Thompson, R. C., Jöhren, R., Vollbrecht, J., Hannen, V., & Vogel, M. (2013) · Physical Review A · doi:10.1103/physreva.87.033423 · Cited by 48
One electron in an orthogonalized cylindrical Penning trap
Tan, J., & Gabrielse, G. (1989) · Applied Physics Letters · doi:10.1063/1.102084 · Cited by 46
Self-citationHigh-precision mass spectrometer for light ions
Heiße, F., Rau, S., Köhler-Langes, F., Quint, W., Werth, G., Sturm, S., & Blaum, K. (2019) · Physical Review A · doi:10.1103/physreva.100.022518 · Cited by 52
Optimized planar Penning traps for quantum-information studies
Goldman, J., & Gabrielse, G. (2010) · Physical Review A · doi:10.1103/physreva.81.052335 · Cited by 44
Self-citationvan Agthoven, M. A., Delsuc, M., Bodenhausen, G., & Rolando, C. H. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6422-8 · Cited by 48
Roux, C., Böhm, C., Dörr, A., Eliseev, S., George, S., Goncharov, M., Novikov, Y. N., Repp, J., Sturm, S., Ulmer, S., et al. (2011) · Applied Physics B · doi:10.1007/s00340-011-4825-4 · Cited by 55
Penning trap mass spectrometry of radionuclides
Kluge, H. ‐. (2013) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2013.04.017 · Cited by 51
Proposed precision laser spectrometer for trapped, highly charged ions
Vogel, M., Winters, D., Segal, D. M., & Thompson, R. C. (2005) · Review of Scientific Instruments · doi:10.1063/1.2069742 · Cited by 42
Temperature measurement of a single ion in a Penning trap
Djekic, S., Alonso, J., Kluge, H.-J., Quint, W., Stahl, S., Valenzuela, T., Verd�, J., Vogel, M., & Werth, G. (2004) · The European Physical Journal D · doi:10.1140/epjd/e2004-00168-1 · Cited by 40
van Agthoven, M. A., Barrow, M. P., Chiron, L., Coutouly, M., Kilgour, D. P. A., Wootton, C. A., Wei, J., Soulby, A., Delsuc, M., Rolando, C. H., et al. (2015) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-015-1226-7 · Cited by 40
“0 V on the analyzer entrance lens before trapping) was used to transfer the ions to the infinity cell [24].”
MethodCompression of trapped positrons in a single particle regime by a rotating electric field
Greaves, R. G., & Moxom, J. (2008) · Physics of Plasmas · doi:10.1063/1.2956335 · Cited by 42
Marto, J. A., Guan, S., Marshall, A. G., & Buchanan, M. V. (1994) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290080809 · Cited by 38
Sympathetic cooling of a trapped proton mediated by an LC circuit
Bohman, M., Grunhofer, V., Smorra, C., Wiesinger, M., Will, C., Borchert, M. J., Devlin, J. A., Erlewein, S., Fleck, M., Gavranovic, S., et al. (2021) · Nature · doi:10.1038/s41586-021-03784-w · Cited by 48
Absorption‐mode spectra on the dynamically harmonized Fourier transform ion cyclotron resonance cell
Qi, Y., Witt, M., Jertz, R., Baykut, G., Barrow, M. P., Николаев, Е. Н., & O’Connor, P. B. (2012) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.6311 · Cited by 38
An experiment for the direct determination of the g-factor of a single proton in a Penning trap
Rodegheri, C. C., Blaum, K., Kracke, H., Kreim, S., Mooser, A., Quint, W., Ulmer, S., & Walz, J. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/6/063011 · Cited by 37
“By means of a proper choice of the trap geometry and tuning ratio, C4 and C6 can be eliminated simultaneously, thus providing compensation of the potential in the lowest order [34, 35].”
BackgroundElectronic detection of charged particle effects in a Penning trap
Winters, D., Vogel, M., Segal, D. M., & Thompson, R. C. (2006) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/39/14/019 · Cited by 38
Electron g‐factor determinations in Penning traps
Sturm, S., Werth, G., & Blaum, K. (2013) · Annalen der Physik · doi:10.1002/andp.201300052 · Cited by 33
Low-order longitudinal modes of single-component plasmas
Tinkle, M. D., Greaves, R. G., & Surko, C. M. (1995) · Physics of Plasmas · doi:10.1063/1.871188 · Cited by 33
Long-term coherence of the cyclotron mode in a trapped ion cloud
Peurrung, A. J., & Kouzes, R. T. (1994) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.49.4362 · Cited by 33
A reservoir trap for antiprotons
Smorra, C., Mooser, A. H., Franke, K., Nagahama, H., Schneider, G. L., Higuchi, T., Gorp, S. V., Blaum, K., Matsuda, Y., Quint, W., et al. (2015) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2015.08.007 · Cited by 45
Dynamics of laser-cooled Ca+ ions in a Penning trap with a rotating wall
Bharadia, S., Vogel, M., Segal, D. M., & Thompson, R. C. (2012) · Applied Physics B · doi:10.1007/s00340-012-4871-6 · Cited by 34
Tolmachev, A. V., Monroe, M. E., Jaitly, N., Petyuk, V., Adkins, J., & Smith, R. D. (2006) · Analytical Chemistry · doi:10.1021/ac0606251 · Cited by 32
Linear excitation and detection in Fourier transform ion cyclotron resonance mass spectrometry
Grosshans, P. B., Chen, R., Limbach, P. A., & Marshall, A. G. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)90034-5 · Cited by 32
A Penning trap for advanced studies with particles in extreme laser fields
Vogel, M., Quint, W., Paulus, G. G., & Stöhlker, T. (2012) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2012.05.001 · Cited by 36
Sympathetic cooling of a trapped proton mediated by an LC circuit
Bohman, M., Grunhofer, V., Smorra, C., Wiesinger, M., Will, C., Borchert, M. J., Devlin, J. A., Erlewein, S., Fleck, M., Gavranovic, S., et al. (2021) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/14469 · Cited by 31
Observing a single hydrogen-like ion in a Penning trap at T = 4 K
Diederich, M., Häffner, H., Hermanspahn, N., Immel, M., Kluge, H.-J., Ley, R., Mann, R., Quint, W., Ståhl, S., & Werth, G. (1998) · Hyperfine Interactions · doi:10.1023/a:1012665109427 · Cited by 36
Towards electronic g-factor measurements in medium-heavy hydrogen-like and lithium-like ions
Vogel, M., Alonso, J., Djekić, S., Kluge, H. J., Quint, W., Ståhl, S., Verdú, J., & Werth, G. (2005) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2005.03.136 · Cited by 35
Moore, F. L., Brown, L. S., Farnham, D. L., Jeon, S., Schwinberg, P. B., & Dyck, R. S. V. (1992) · Physical Review A · doi:10.1103/physreva.46.2653 · Cited by 34
Ion dynamics in perturbed quadrupole ion traps
Horváth, G., Hernández‐Pozos, J. L., Dholakia, K., Rink, J., Segal, D. M., & Thompson, R. C. (1998) · Physical Review A · doi:10.1103/physreva.57.1944 · Cited by 28
Design and performance of a new FT-ICR cell operating at a temperature range of 77–438 K
Guo, X., Duursma, M. C., Al-Khalili, A., McDonnell, L. A., & Heeren, R. M. A. (2003) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2003.08.016 · Cited by 28
Advances in trapped ion cells for Fourier transform ion cyclotron resonance mass spectrometry
Vartanian, V., Anderson, J. S., & Laude, D. A. (1995) · Mass Spectrometry Reviews · doi:10.1002/mas.1280140102 · Cited by 30
Peurrung, A. J., Kouzes, R. T., & Barlow, S. E. (1996) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(96)04395-9 · Cited by 30
Metadata
- Authors
- Gabrielse, G., Haarsma, L., & Rolston, S. L.
- Affiliations
- Harvard University (US)
- Venue
- International Journal of Mass Spectrometry and Ion Processes
- Publisher
- Elsevier BV
- Published
- 1989-04
- Volume
- 88
- Issue
- 2-3
- Pages
- 319-332
- ISSN
- 0168-1176 (ISSN-L)
- OpenAlex
- W1979044941
- Semantic Scholar
- 9cb4e78bc7ef4b434673d831e0ff9f38d84c1027
- Cited by
- 288
- References
- 15
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 12 · 2023: 5 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 9 · 2018: 9 · 2017: 15 · 2016: 4 · 2015: 15 · 2014: 11 · 2013: 18 · 2012: 14
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- International Journal of Mass Spectrometry and Ion Processes (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Keywords
- Penning trap, cylindrical trap, antiproton cooling, antihydrogen production, anharmonicity, electrode gap
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.