The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Safety of rapid-rate transcranial magnetic stimulation in normal volunteers
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PENFIELD, W., & BOLDREY, E. (1937) · Brain · doi:10.1093/brain/60.4.389 · Cited by 4,188
EPILEPSY AND THE FUNCTIONAL ANATOMY OF THE HUMAN BRAIN
Penfield, W., & Jasper, H. (1954) · Southern Medical Journal · doi:10.1097/00007611-195407000-00024 · Cited by 4,092
A permanent change in brain function resulting from daily electrical stimulation
Goddard, G. V., McIntyre, D. C., & Leech, C. K. (1969) · Experimental Neurology · doi:10.1016/0014-4886(69)90128-9 · Cited by 3,052
Surgical treatment of the epilepsies
Engel, J. (1993) · Raven Press eBooks · Cited by 1,778
Horizontal spread of synchronized activity in neocortex and its control by GABA-mediated inhibition
Chagnac-Amitai, Y., & Connors, B. W. (1989) · Journal of Neurophysiology · doi:10.1152/jn.1989.61.4.747 · Cited by 539
Induction of speech arrest and counting errors with rapid‐rate transcranial magnetic stimulation
Pascual‐Leone, A., Gates, J. R., & Dhuna, A. (1991) · Neurology · doi:10.1212/wnl.41.5.697 · Cited by 508
Self-citationWAXMAN, S. G., & BENNETT, M. V. L. (1972) · Nature New Biology · doi:10.1038/newbio238217a0 · Cited by 444
Effects of coil design on delivery of focal magnetic stimulation. Technical considerations
Cohen, L. G., Roth, B. J., Nilsson, J., Dang, N., Panizza, M., Bandinelli, S., Friauf, W., & Hallett, M. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90113-x · Cited by 409
Self-citationKindling: basic mechanisms and clinical validity
Sato, M., Racine, R. J., & McIntyre, D. C. (1990) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(90)90099-6 · Cited by 314
A theoretical calculation of the electric field induced in the cortex during magnetic stimulation
Roth, B. J., Saypol, J. M., Hallett, M., & Cohen, L. G. (1991) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(91)90103-5 · Cited by 307
Self-citation
Cited by
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367
Self-citationWassermann, E. M. (1998) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(97)00096-8 · Cited by 2,293
Self-citationRossi, S., Antal, A., Bestmann, S., Bikson, M., Brewer, C., Brockmöller, J., Carpenter, L. L., Cincotta, M., Chen, R., Daskalakis, J. D., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.10.003 · Cited by 1,573
Self-citationPascual-Leone, A., Rubio, B., Pallardó, F., & Catalá, M. D. (1996) · The Lancet · doi:10.1016/s0140-6736(96)01219-6 · Cited by 1,229
Self-citationTranscranial magnetic stimulation and cognitive neuroscience
Walsh, V., & Cowey, A. (2000) · Nature Reviews Neuroscience · doi:10.1038/35036239 · Cited by 814
Metadata
- Authors
- Pascual-Leone, A., Houser, C. M., Reese, K., Shotland, L. I., Grafman, J., Sato, S., Valls-Solé, J., Brasil-Neto, J. P., Wassermann, E. M., Cohen, L. G., & Hallett, M.
- Venue
- Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section
- Publisher
- Elsevier BV
- Published
- 1993-04
- Volume
- 89
- Issue
- 2
- Pages
- 120-130
- ISSN
- 0168-5597 (ISSN-L)
- OpenAlex
- W1989379906
- Cited by
- 408
- References
- 32
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Safety of rapid-rate transcranial magnetic stimulation in normal volunteers. https://app.cochat.ai/papers/10.1016/0168-5597(93)90094-6
- The paper
- Pascual-Leone, A., Houser, C. M., Reese, K., Shotland, L. I., Grafman, J., Sato, S., Valls-Solé, J., Brasil-Neto, J. P., Wassermann, E. M., Cohen, L. G., & Hallett, M. (1993). Safety of rapid-rate transcranial magnetic stimulation in normal volunteers. Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section. https://doi.org/10.1016/0168-5597(93)90094-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.