A new type of X-ray area detector utilizing laser stimulated luminescence
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Autoradiography using storage phosphor technology
Johnston, R. F., Pickett, S. C., & Barker, D. L. (1990) · ELECTROPHORESIS · doi:10.1002/elps.1150110503 · Cited by 512
Imaging plate illuminates many fields
Amemiya, Y., & Miyahara, J. (1988) · Nature · doi:10.1038/336089a0 · Cited by 495
Self-citationStructure of ribonuclease H phased at 2 a resolution by MAD analysis of the selenomethionyl protein
Yang, W., Hendrickson, W. A., Crouch, R. J., & Satow, Y. (1990) · Science · doi:10.1126/science.2169648 · Cited by 473
Self-citationSakabe, N. (1991) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(91)90282-u · Cited by 229
High-energy Kα radiography using high-intensity, short-pulse lasers
Park, H.-S., Chambers, D. M., Chung, H.-K., Clarke, R. J., Eagleton, R., Giraldez, E., Goldsack, T., Heathcote, R., Izumi, N., Key, M. H., et al. (2006) · Physics of Plasmas · doi:10.1063/1.2178775 · Cited by 215
An imaging plate neutron detector
Niimura, N., Karasawa, Y., Tanaka, I., Miyahara, J., Takahashi, K., Saito, H., Koizumi, S., & Hidaka, M. (1994) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(94)91220-3 · Cited by 191
Self-citationYamanaka, K., Yamaguchi, T., & Wakita, H. (1994) · The Journal of Chemical Physics · doi:10.1063/1.467948 · Cited by 182
Kita, A., Kita, S.-I., Fujisawa, I., Inaka, K., Ishida, T., Horiike, K., Nozaki, M., & Miki, K. (1999) · Structure · doi:10.1016/s0969-2126(99)80006-9 · Cited by 177
“X-ray diffraction data were collected at a wavelength of 1.0 Å using synchrotron radiation with a screenless Weissenberg camera at the BL-6A beam line of the Photon Factory, Institute of Material Structure Science, High Energy Accelerator Research Organization (formerly the National Laboratory for High Energy Physics)…”
MethodInfluentialDesign and performance of an imaging plate system for X-ray diffraction study
Amemiya, Y., Matsushita, T., Nakagawa, A., Satow, Y., Miyahara, J., & Chikawa, J.-I. (1988) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(88)90458-5 · Cited by 171
Self-citationNogi, T., Fathir, I., Kobayashi, M., Nozawa, T., & Miki, K. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.240224997 · Cited by 166
Diagnostics for plasma-based electron accelerators
Downer, M. C., Zgadzaj, R., Debus, A., Schramm, U., & Kaluza, M. C. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035002 · Cited by 159
“IPs, also developed for medical radiography (Amemiya and Miyahara, 1988; Miyahara et al., 1986), are based on photo-stimulated luminescence (PSL) (Iwabuchi et al., 1994).”
Background
Metadata
- Authors
- Miyahara, J., Takahashi, K., Amemiya, Y., Kamiya, N., & Satow, Y.
- Venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publisher
- Elsevier BV
- Published
- 1986-05
- Volume
- 246
- Issue
- 1-3
- Pages
- 572-578
- ISSN
- 0168-9002 (ISSN-L)
- OpenAlex
- W2034027861
- Cited by
- 320
- References
- 0
- FWCI
- 23.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.