The DOI matches its Crossref record.
Calibration and correction of spatial distortions in 2D detector systems
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Two-dimensional detector software: From real detector to idealised image or two-theta scan
Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D. (1996) · High Pressure Research · doi:10.1080/08957959608201408 · Cited by 4,674
Self-citationFIT2D: a multi-purpose data reduction, analysis and visualization program
Hammersley, A. P. (2016) · Journal of Applied Crystallography · doi:10.1107/s1600576716000455 · Cited by 782
Self-citationStructural Analysis of Molecular Materials Using the Pair Distribution Function
Terban, M. W., & Billinge, S. J. L. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00237 · Cited by 426
Wang, L., Ding, J., Chen, S., Jin, K., Zhang, Q., Cui, J., Wang, B., Chen, B., Li, T., Ren, Y., et al. (2023) · Nature Materials · doi:10.1038/s41563-023-01517-0 · Cited by 361
Wang, J. X., Ma, C., Choi, Y., Su, D., Zhu, Y., Liu, P., Si, R., Vukmirovic, M. B., Zhang, Y., & Adzic, R. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja204518x · Cited by 270
Metadata
- Authors
- Hammersley, A. P., Svensson, S. O., & Thompson, A.
- Venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publisher
- Elsevier BV
- Published
- 1994-07
- Volume
- 346
- Issue
- 1-2
- Pages
- 312-321
- ISSN
- 0168-9002 (ISSN-L)
- OpenAlex
- W2034747755
- Cited by
- 413
- References
- 0
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration and correction of spatial distortions in 2D detector systems. https://app.cochat.ai/papers/10.1016/0168-9002(94)90720-x
- The paper
- Hammersley, A. P., Svensson, S. O., & Thompson, A. (1994). Calibration and correction of spatial distortions in 2D detector systems. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. https://doi.org/10.1016/0168-9002(94)90720-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.