The DOI matches its Crossref record.
Two-dimensional detector software: From real detector to idealised image or two-theta scan
Abstract
Detector systems introduce distortions into acquired data. To obtain accurate angle and intensity information, it is necessary to calibrate, and apply corrections. Intensity non-linearity, spatial distortion, and non-uniformity of intensity response, are the primary considerations. It is better to account for the distortions within scientific analysis software, but often it is more practical to correct the distortions to produce ‘idealised’ data. Calibration methods and software have been developed for single crystal diffraction experiments, using both approaches. For powder diffraction experiments the additional task of converting a two-dimensional image to a one-dimensional spectrum is used to allow Rietveld analysis. This task may be combined with distortion correction to produce intensity information and error estimates. High-pressure experiments can introduce additional complications and place new demands on software. Flexibility is needed to be able to integrate different angular regions separately, and to produce profiles as a function of angle of azimuth. Methods to cope with awkward data are described, and examples of the techniques applied to data from high pressure experiments are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ordered ferrimagnetic form of ferrihydrite reveals links among structure, composition, and magnetism
Michel, F. M., Barrón, V., Torrent, J., Morales, M. P., Serna, C. J., Boily, J.-F., Liu, Q., Ambrosini, A., Cismasu, A. C., & Brown, G. E. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910170107 · Cited by 375
A new multipurpose diffractometer PILATUS@SNBL
Dyadkin, V., Pattison, P., Dmitriev, V., & Chernyshov, D. (2016) · Journal of Synchrotron Radiation · doi:10.1107/s1600577516002411 · Cited by 363
Competitive I2 Sorption by Cu-BTC from Humid Gas Streams
Sava, D. F., Chapman, K. W., Rodriguez, M. A., Greathouse, J. A., Crozier, P. S., Zhao, H., Chupas, P. J., & Nenoff, T. M. (2013) · Chemistry of Materials · doi:10.1021/cm401762g · Cited by 363
Shadike, Z., Lee, H., Borodin, O., Cao, X., Fan, X., Wang, X., Lin, R., Bak, S.-M., Ghose, S., Xu, K., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-020-00845-5 · Cited by 320
Structural Characteristics of Synthetic Amorphous Calcium Carbonate
Michel, F. M., MacDonald, J., Feng, J., Phillips, B. L., Ehm, L., Tarabrella, C., Parise, J. B., & Reeder, R. J. (2008) · Chemistry of Materials · doi:10.1021/cm800324v · Cited by 241
Metadata
- Authors
- Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D.
- Venue
- High Pressure Research
- Publisher
- Informa UK Limited
- Published
- 1996-01
- Volume
- 14
- Issue
- 4-6
- Pages
- 235-248
- ISSN
- 0895-7959 (ISSN-L)
- 1477-2299
- OpenAlex
- W1983874564
- Cited by
- 4,674
- References
- 0
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-dimensional detector software: From real detector to idealised image or two-theta scan. https://app.cochat.ai/papers/10.1080/08957959608201408
- The paper
- Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D. (1996). Two-dimensional detector software: From real detector to idealised image or two-theta scan. High Pressure Research. https://doi.org/10.1080/08957959608201408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.