Energetics of advanced integrated wastewater pond systems
The DOI matches its Crossref record.
Abstract
An energy balance is presented for a second generation Advanced Integrated Wastewater Pond System (AIWPS) prototype at the University of California, Berkeley, Environmental Engineering and Health Sciences Laboratory in Richmond, California. Modifications were made to the existing 1.8 ML facultative pond in order to further optimize methane fermentation and to demonstrate the recovery of methane using a submerged gas collector. Methane production rates were determined over a range of in-pond digester loadings and temperatures. The feasibility of submerged gas collection was proven, and the advantages of in-pond digestion in terms of BOD 5 and VSS removal as well as biogas scrubbing were quantified. Biogas methane concentrations increased by more than 50% as the biogas emerged through the overlying water column and most of the carbon dioxide fraction was utilized by microalgae. Electrical power requirements for mixing two 0.1 hectare algal High Rate Ponds (HRPs) were measured over a range of channel depths and velocities, and electrical power requirements for daily recirculation pumping were also measured. Oxygenation and total treatment energy requirements for the second generation AIWPS prototype at Richmond were compared with oxygenation and total treatment energy requirements for the first generation AIWPS at St. Helena, California and for two mechanical wastewater treatment plants of comparable capacity and effluent quality at Pinole and Brentwood, California. Using preliminary methane production and recovery rates achieved at Richmond, the cogeneration potential was estimated and projected for larger second generation AIWPSs of 2 MLD and 200 MLD capacities. By incorporating methane recovery and electrical power generation together with efficient HRP mixing using paddle wheels, full-scale second generation AIWPSs will be able to produce as much energy as they require for primary and secondary treatment. Additional energy would be required to produce a tertiary disinfected effluent suitable for unrestricted reuse in California, including recreational and indirect potable reuse. The additional power requirements for complete algal harvest using dissolved air flotation (DAF) and filtration were estimated for second generation AIWPSs based on data collected at Richmond and Stockton, California, and the additional power requirements for final UV disinfection were estimated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Potential of Sustainable Algal Biofuel Production Using Wastewater Resources
Pittman, J. K., Dean, A. P., & Osundeko, O. (2011) · Bioresource Technology · doi:10.1016/j.biortech.2010.06.035 · Cited by 1,526
“…oxidation (stabilization) ponds or the more developed suspended algal pond systems such as high-rate algal ponds which are shallow raceway-type oxidation ponds with mechanical mixing, and have been shown to be highly effective for wastewater treatment (Green et al., 1995; Hoffmann, 1998).”
BackgroundMethodRawat, I., Ranjith Kumar, R., Mutanda, T., & Bux, F. (2011) · Applied Energy · doi:10.1016/j.apenergy.2010.11.025 · Cited by 1,185
Anaerobic digestion of algae biomass: A review
Ward, A. J., Lewis, D. M., & Green, F. B. (2014) · Algal Research · doi:10.1016/j.algal.2014.02.001 · Cited by 581
Self-citationWoertz, I., Feffer, A., Lundquist, T., & Nelson, Y. (2009) · Journal of Environmental Engineering · doi:10.1061/(asce)ee.1943-7870.0000129 · Cited by 516
Microalgae wastewater treatment: Biological and technological approaches
Wollmann, F., Dietze, S., Ackermann, J., Bley, T., Walther, T., Steingroewer, J., & Krujatz, F. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201900071 · Cited by 370
Nitrogen availability influences phosphorus removal in microalgae-based wastewater treatment
Beuckels, A., Smolders, E., & Muylaert, K. (2015) · Water Research · doi:10.1016/j.watres.2015.03.018 · Cited by 347
The Use of Microalgae for Coupling Wastewater Treatment with CO2 biofixation
Molazadeh, M., Ahmadzadeh, H., Pourianfar, H. R., Lyon, S., & Rampelotto, P. H. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00042 · Cited by 321
Wastewater treatment and algal production in high rate algal ponds with carbon dioxide addition
Park, J. B. K., & Craggs, R. J. (2010) · Water Science and Technology · doi:10.2166/wst.2010.951 · Cited by 310
Kadir, W. N. A., Lam, M. K., Uemura, Y., Lim, J. W., & Lee, K. T. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.06.074 · Cited by 256
Javed, F., Aslam, M., Rashid, N., Shamair, Z., Khan, A. L., Yasin, M., Fazal, T., Hafeez, A., Rehman, F., Rehman, M. S. U., et al. (2019) · Fuel · doi:10.1016/j.fuel.2019.115826 · Cited by 219
Long term diurnal variations in contaminant removal in high rate ponds treating urban wastewater
García, J., Green, B. F., Lundquist, T., Mujeriego, R., Hernández-Mariné, M., & Oswald, W. J. (2006) · Bioresource Technology · doi:10.1016/j.biortech.2005.07.019 · Cited by 217
Craggs, R., Park, J., Heubeck, S., & Sutherland, D. (2014) · New Zealand Journal of Botany · doi:10.1080/0028825x.2013.861855 · Cited by 212
“Capital and operating costs of HRAP systems for secondary wastewater treatment (BOD5 removal) are estimated to be only one quarter to one third those of electromechanical secondary-level activated sludge treatment (Green et al. 1995; Downing et al. 2002).”
BackgroundMy sixty years in applied algology
Oswald, W. J. (2003) · Journal of Applied Phycology · doi:10.1023/a:1023871903434 · Cited by 209
“These topics have occupied the attention over the past many years of my current close colleagues, Dr Bailey Green and Tryg Lundquist (Green et al., 1995).”
BackgroundMethodA Brief Review of Anaerobic Digestion of Algae for Bioenergy
Milledge, J. J., Nielsen, B. V., Maneein, S., & Harvey, P. J. (2019) · Energies · doi:10.3390/en12061166 · Cited by 191
“4 kWh·kg−1 BOD removed in mechanical aerated ponds [59,68,69].”
BackgroundConnecting phosphorus loss from agricultural landscapes to surface water quality
McDowell, R. W., Biggs, B. J. F., Sharpley, A. N., & Nguyen, L. (2004) · Chemistry and Ecology · doi:10.1080/02757540310001626092 · Cited by 184
“, 1995; 1998) and some features of the advanced integrated wastewater pond systems (Green et al., 1995) such as high rate algal ponds (HRAP), maturation ponds and algae settling ponds are often incorporated into the WSP system.”
Backgroundhattab, M. A. (2015) · Journal of Fundamentals of Renewable Energy and Applications · doi:10.4172/2090-4541.1000154 · Cited by 159
“Algae harvest using dissolved air flotation is an efficient method but has high operational costs that are associated with the use of energy intensive compressor that function at pressures of 390 kPa [131-133].”
MethodPotential of microalgae in bioremediation of wastewater
Ahmad, I., Abdullah, N., Koji, I., Yuzir, A., & Mohamad, S. E. (2021) · Bulletin of Chemical Reaction Engineering & Catalysis · doi:10.9767/bcrec.16.2.10616.413-429 · Cited by 71
Nutrient Removal & Greenhouse Gas Abatement with CO2 Supplemented Algal High Rate Ponds
Woertz, I., Fulton, L., & Lundquist, T. (2009) · Proceedings of the Water Environment Federation · doi:10.2175/193864709793900177 · Cited by 29
Self-citation
Metadata
- Venue
- Water Science and Technology
- Publisher
- IWA Publishing
- Published
- 1995
- Volume
- 31
- Issue
- 12
- ISSN
- 0273-1223 (ISSN-L)
- OpenAlex
- W2029179387
- Cited by
- 114
- References
- 0
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.