CoChat

Effects of electrical and mechanical stimulation on two foci of spontaneous activity which develop in primary afferent neurons after peripheral axotomy

Burchiel, Kim J. · 1984 · Pain
Cited by 121

The DOI matches its Crossref record.

Abstract

In 28 Sprague-Dawley rats, unilateral division of the sciatic nerve at the level of the midfemur was performed. Animals were observed for behavioral changes for 1-21 days, and electrophysiological recordings were made from microfilaments dissected from the ipsilateral L5 dorsal rootlets and sciatic nerve from 1 to 14 days postoperatively. Spontaneous discharges of two types were recorded: (1) variable frequency (0-100 Hz) discharges which typically occurred in rhythmic bursts and could be driven by mechanical stimulation of the neuroma; and (2) lower frequency (0.25-14 Hz) irregular activity which persisted after either excision or local anesthesia of the neuroma. The latter activity could also be recorded from the proximal cut end of the sciatic nerve following removal of the neuroma. The first type of activity was felt to be produced from the neuroma while the second originated in the region of the dorsal root ganglion (DRG). Analysis of the conduction velocities of fibers involved in each type of discharge indicated that both involved smaller myelinated filaments. However, the DRG activity involved significantly smaller fibers with conduction velocities in the A delta range. Spontaneous activity was recorded at 3 and 4 days for the neuroma and DRG activity, respectively. Ongoing discharges maximized at 7-10 days and were rare by 14 days. Autotomy of the ipsilateral foot was found to occur over a similar time course. Tetanic electrical stimulation (100 Hz) produced either little change in the baseline firing rate or prolonged afterdischarges in fibers manifesting neuroma activity. In fibers with ongoing activity of DRG origin, stimulation produced a stereotyped, brief low-frequency afterburst and then prolonged inhibition of firing. Mechanical stimulation of the neuroma produced both brief increases in spontaneous discharges and prolonged afterdischarges. In fibers with spontaneous DRG activity, minimal mechanical stimulation of their ganglion of origin produced high-frequency firing. This study demonstrates that peripheral axotomy of DRG neurons produces spontaneous activity distinct from ongoing neuroma activity in a proportion of fibers which are potentially nociceptive (A delta) as well as abnormal mechanosensitivity of the DRG. Furthermore, electrical stimulation of these fibers produces prolonged inhibition of the discharge. This finding may partially explain the prolonged relief of symptoms patients with chronic pain of peripheral origin may experience following peripheral tetanic electrical stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0304-3959(84)90820-0

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 121

Metadata

Authors
Burchiel, K. J.
Venue
Pain
Published
1984-03
Volume
18
Issue
3
Pages
249-265
ISSN
0304-3959 (ISSN-L)
OpenAlex
W1990025105
Cited by
121
References
0
FWCI
7.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of electrical and mechanical stimulation on two foci of spontaneous activity which develop in primary afferent neurons after peripheral axotomy. https://app.cochat.ai/papers/10.1016/0304-3959(84)90820-0
The paper
Burchiel, K. J. (1984). Effects of electrical and mechanical stimulation on two foci of spontaneous activity which develop in primary afferent neurons after peripheral axotomy. Pain. https://doi.org/10.1016/0304-3959(84)90820-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.