CoChat

Laser-evoked cerebral potentials and sensory function in patients with central pain

Casey, K. L., Beydoun, A., Boivie, J., Sjolund, B., Holmgren, H., Leijon, G., Morrow, T. J., Rosen, I. · 1996 · Pain
Cited by 88

The DOI matches its Crossref record.

Abstract

Central pain syndromes (CPS) could be caused by disinhibition of spinothalamic excitability or by other central nervous system (CNS) changes caused by reduced spinothalamic function. To examine these possibilities, we studied 11 patients (ages 51-82 years) with unilateral central pain and with reproducible cerebral evoked vertex potentials in response to cutaneous stimulation of the normal side with pulses from an infra-red CO2 laser. All patients had normal tactile and kinesthetic sensation; one had slightly decreased vibratory sense bilaterally. All showed, from the unaffected (asymptomatic) side, laser evoked potentials (LEPs) with negative (N) components ranging from 208 to 280 msec peak latency (av: 240 +/- 6 SE msec) and peak amplitudes of 1-7 microV (av: 2.9 +/- 0.5 SE microV), followed, in all but 1 patient, by positive (P) potentials ranging from 288 to 370 msec peak latency (av: 319 +/- 7.7 SE msec) with peak amplitudes of 1-7 microV (2.8 +/- 0.5 SE microV). Laser stimulation of the affected (symptomatic) side in 5 patients evoked LEPs with N-P interpeak amplitudes that were within 20% of those evoked from the normal side. All but one of these patients had thresholds for warm, heat pain, and deep pain that were normal in comparison with the unaffected side. The excepted patient had the largest N-P interpeak amplitude asymmetry (18.5%) of this group. Ratings of laser pulse intensity were either symmetrical (n = 2) or increased on the affected side (n = 3) in these patients. In contrast, laser stimulation of the affected side failed to evoke either N or P potentials in 6 patients, all of whom had lateralized increased thresholds for warm, heat pain, or deep pain, or reduced ratings of laser pulse sensation. Although 1 patient had increased ratings of laser pulse sensation, the amplitude of the LEP was always reduced on the side of increased pain or heat threshold in these CPS patients (Fisher exact test: P = 0.015). These results reflect primarily a deficit in spinothalamic tract function and do not suggest excessive CNS responses to synchronous activation of cutaneous heat nociceptors in patients with CPS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0304-3959(95)00143-3

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 88

Metadata

Authors
Casey, K. L., Beydoun, A., Boivie, J., Sjolund, B., Holmgren, H., Leijon, G., Morrow, T. J., & Rosen, I.
Venue
Pain
Published
1996-03
Volume
64
Issue
3
Pages
485-491
ISSN
0304-3959 (ISSN-L)
OpenAlex
W2026426064
Cited by
88
References
0
FWCI
5.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laser-evoked cerebral potentials and sensory function in patients with central pain. https://app.cochat.ai/papers/10.1016/0304-3959(95)00143-3
The paper
Casey, K. L., Beydoun, A., Boivie, J., Sjolund, B., Holmgren, H., Leijon, G., Morrow, T. J., & Rosen, I. (1996). Laser-evoked cerebral potentials and sensory function in patients with central pain. Pain. https://doi.org/10.1016/0304-3959(95)00143-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.