CoChat

Multiple session experimental pain measurement

Yarnitsky, David, Sprecher, Elliot, Zaslansky, Ruth, Hemli, Jeshayachu A. · 1996 · Pain
Cited by 125

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Experimental heat pain transients were administered to 30 normal volunteers over four weekly sessions, measuring both heat pain (HP) threshold and suprathreshold magnitude estimation through VAS. Repeatability and bias for these two factors were evaluated. Heat pain thresholds measured through the method of limits were previously shown to have inter-session bias, presumably due to a practice effect. Existence of such a bias between first and second measurement sessions casts doubt on the usefulness of this parameter for pain assessment of individuals over time. In the present study, measurements of normal HP thresholds over four sessions showed that bias exists between the first and successive sessions, but not among sessions other than the first. It is concluded that (i) HP thresholds obtained from a single session are of limited value, and should be carefully interpreted. (ii) Long-term studies that use the HP threshold should take results from the second (or later) session as their baseline. The Visual Analog Scale (VAS) is considered the 'gold standard' for assessment of clinical and suprathreshold experimental pain, and changes in VAS score are regarded as significant evidence of individual response to treatment, placebo, or experimental manipulation. Although its overall group accuracy and precision have been examined for both clinical and experimental pain, and found adequate (Price 1988), the VAS has not been rigorously assessed for repeatability. Stimuli at three pain levels, 1.5, 3 and 4.5 degrees C above each individual's heat pain threshold as determined at each session, were given. Several models of analysis of the VAS were tested and repeatabilities (r) obtained from these analyses demonstrate poor precision for each of the tested analysis models. For example, inter-session repeatabilities for the three individual pain levels ranged from r = 3.8-4.7, effectively providing a confidence interval of 7.6-9.4 for any VAS reading on a 0- to 10-point scale. An examination of intra-session VAS provided somewhat better results. Thus, use of the VAS in similar experimental settings is called into question. The use of the VAS in clinical settings, where individual assessments are necessary, is also called into question, but remains to be specifically tested.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0304-3959(96)03110-7

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 125

Metadata

Authors
Yarnitsky, D., Sprecher, E., Zaslansky, R., & Hemli, J. A.
Venue
Pain
Published
1996-10
Volume
67
Issue
2
Pages
327-333
ISSN
0304-3959 (ISSN-L)
OpenAlex
W2084456270
Cited by
125
References
7
FWCI
0.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiple session experimental pain measurement. https://app.cochat.ai/papers/10.1016/0304-3959(96)03110-7
The paper
Yarnitsky, D., Sprecher, E., Zaslansky, R., & Hemli, J. A. (1996). Multiple session experimental pain measurement. Pain. https://doi.org/10.1016/0304-3959(96)03110-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.