The DOI matches its Crossref record.
Detector geometry, thermal diffuse scattering and strain effects in ADF STEM imaging
Open accessAbstract
Intensities of atomic-resolution Annular Dark Field Scanning Transmission Electron Microscopy (ADF STEM) images of zone-axis-oriented specimens change with defocus at rates that depend on lattice spacing. Thickness and strain effects on the intensities have been demonstrated. In this paper, image simulations (with some experimental basis) are presented that consider the dimensions of the ADF detector. Changing the inner radius of the detector seems to have relatively small effect on the image except to lower the detected intensity. Probe size was explored and a case identified where multiple scattering was important in the image. Thermal diffuse scattering (TDS) is important in high-angle scattering at room temperatures but it does not seem to alter the image appearance markedly. Finally, the image arising from the strain field around a single boron atom has been simulated and the results suggest increased scattering in agreement with observations. This mechanism may be adequate for single impurity atom detection at low temperatures and with special detector angles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Three-dimensional atomic imaging of crystalline nanoparticles
Van Aert, S., Batenburg, K. J., Rossell, M. D., Erni, R., & Van Tendeloo, G. (2011) · Nature · doi:10.1038/nature09741 · Cited by 561
Atomic-scale imaging of individual dopant atoms and clusters in highly n-type bulk Si
Voyles, P. M., Muller, D. A., Grazul, J. L., Citrin, P. H., & Gossmann, H.-J. L. (2002) · Nature · doi:10.1038/416826a · Cited by 434
Conditions and reasons for incoherent imaging in STEM
Hartel, P., Rose, H., & Dinges, C. (1996) · Ultramicroscopy · doi:10.1016/0304-3991(96)00020-4 · Cited by 411
SrTiO3-based thermoelectrics: Progress and challenges
Shi, X.-L., Wu, H., Liu, Q., Zhou, W., Lu, S., Shao, Z., Dargusch, M., & Chen, Z.-G. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105195 · Cited by 259
Hsieh, Y.-C., Zhang, Y., Su, D., Volkov, V., Si, R., Wu, L., Zhu, Y., An, W., Liu, P., He, P., et al. (2013) · Nature Communications · doi:10.1038/ncomms3466 · Cited by 229
Metadata
- Authors
- Hillyard, S., & Silcox, J.
- Venue
- Ultramicroscopy
- Publisher
- Elsevier BV
- Published
- 1995-04
- Volume
- 58
- Issue
- 1
- Pages
- 6-17
- ISSN
- 0304-3991 (ISSN-L)
- OpenAlex
- W2070552490
- Cited by
- 197
- References
- 0
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detector geometry, thermal diffuse scattering and strain effects in ADF STEM imaging. https://app.cochat.ai/papers/10.1016/0304-3991(94)00173-k
- The paper
- Hillyard, S., & Silcox, J. (1995). Detector geometry, thermal diffuse scattering and strain effects in ADF STEM imaging. Ultramicroscopy. https://doi.org/10.1016/0304-3991(94)00173-k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.