Radiosurgery for the treatment of previously irradiated recurrent primary brain tumors and brain metastases: Initial report of radiation therapy oncology group protocol 90-05

Open access
Shaw, Edward, Scott, Charles, Souhami, Luis, Dinapoli, Robert, Bahary, Jean-Paul, Kline, Robert, Wharam, Moody, Schultz, Christopher, Davey, Phillip, Loeffler, Jay, Del Rowe, John, Marks, Lawrence, Fisher, Barbara, Shin, Kyu · 1996 · International Journal of Radiation Oncology*Biology*Physics

Abstract

PURPOSE: To determine the maximum acutely tolerable dose of single fraction radiosurgery in patients with recurrent previously irradiated primary brain tumors or brain metastases. METHODS AND MATERIALS: Between August 1990 and September 1993, 102 analyzable patients were entered on Radiation Therapy Oncology Group (RTOG) protocol 90-05, 38 of whom had recurrent primary brain tumors (median prior dose 60 Gy), and 64 of whom had recurrent brain metastases (median prior dose 30 Gy) < or = 40 mm in maximum diameter. Unacceptable toxicity was defined as irreversible Grade 3, any Grade 4, or Grade 5 central nervous system (CNS) toxicity according to the RTOG CNS criteria, occurring in > 20% of patients per treatment arm within 3 months of radiosurgery. RESULTS: Patients were initially entered onto one of three treatment arms according to the maximum diameter of the recurrent lesion. Twelve to 22 patients were entered on each arm. The dose levels were: arm 1, < or = 20 mm, 18 Gy; arm 2, 21-30 mm, 15 Gy; and arm 3, 31-40 mm, 12 Gy. Subsequently, doses were escalated as follows: arm 4, < or = 20mm, 21 Gy; arm 5, 21-30 mm 18 Gy; and arm 6, 31-40 mm, 15 Gy. Unacceptable acute toxicity secondary to cerebral edema occurred in 0, 7 and 5% of patients on Arms 1, 2 and 3, respectively, and in no patients on arms 4, 5, or 6. Multivariate analysis revealed that tumor volume > or = 8200 mm(3) and a ratio of maximum dose to prescription dose (MD/PD) > or = 2 were significantly associated unacceptable toxicity. Of 15 patients with both tumor volume > or = 8200 mm(3) and MD/PD > or = 2, unacceptable toxicity occurred in 2 of 4 treated with a single isocenter and 1 of 11 treated with multiple isocenters. Subsequently, operation for symptomatic radionecrosis was required in 6% of patients. CONCLUSION: We found that the incidence of acute toxicity was acceptable at 0-7% in patients with recurrent, previously irradiated primary brain tumors or brain metastases < or = 40 mm in maximum diameter treated according to the protocol described.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0360-3016(95)02106-x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 278

Metadata

Authors
Shaw, E., Scott, C., Souhami, L., Dinapoli, R., Bahary, J.-P., Kline, R., Wharam, M., Schultz, C., Davey, P., Loeffler, J., Del Rowe, J., Marks, L., Fisher, B., & Shin, K.
Venue
International Journal of Radiation Oncology*Biology*Physics
Publisher
Elsevier BV
Published
1996-02
Volume
34
Issue
3
Pages
647-654
ISSN
0360-3016 (ISSN-L)
OpenAlex
W2017660654
Cited by
278
References
13
FWCI
12.98
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiosurgery for the treatment of previously irradiated recurrent primary brain tumors and brain metastases: Initial report of radiation therapy oncology group protocol 90-05. https://app.cochat.ai/papers/10.1016/0360-3016(95)02106-x
The paper
Shaw, E., Scott, C., Souhami, L., Dinapoli, R., Bahary, J.-P., Kline, R., Wharam, M., Schultz, C., Davey, P., Loeffler, J., Del Rowe, J., Marks, L., Fisher, B., & Shin, K. (1996). Radiosurgery for the treatment of previously irradiated recurrent primary brain tumors and brain metastases: Initial report of radiation therapy oncology group protocol 90-05. International Journal of Radiation Oncology*Biology*Physics. https://doi.org/10.1016/0360-3016(95)02106-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.