Cited by 51Analytical Methods in PharmaceuticalsAnalytical Chemistry and ChromatographyAnalytical chemistry methods development

High-performance liquid chromatography of the aromatase inhibitor, letrozole, and its metabolite in biological fluids with automated liquid-solid extraction and fluorescence detection

Marfil, F., Pineau, V., Sioufi, A., Godbillon, J.·1996·Journal of Chromatography B: Biomedical Sciences and Applications

Abstract

An analytical method for the determination of letrozole (CGS 20,267) in plasma and of letrozole and its metabolite, CGP 44,645, in urine is described. Automated liquid-solid extraction of compounds from plasma and urine was performed on disposable 100-mg C8 columns using the ASPEC system. The separation was achieved on an ODS Hypersil C18 column using acetonitrile-phosphate buffer, pH 7, as the mobile phase at a flow-rate of 1.5 ml/min. A fluorescence detector was used for the quantitation. The excitation and emission wavelengths were 230 and 295 nm, respectively. The limits of quantitation (LOQ) of letrozole in plasma and in urine were 1.40 nmol/l (0.4 ng/ml) and 2.80 nmol/l, respectively. The respective mean recoveries and coefficient of variation (C.V.) were 96.5% (9.8%) in plasma and 104% (7.7%) in urine. The LOQ of CGP 44645 in urine was 8.54 nmol/l (2 ng/ml). The mean recovery was 108% (6.3%). The compounds were well separated from co-extracted endogenous components and no interferences were observed at the retention times of compounds. The sensitivity of this method for letrozole in plasma should be sufficient for kinetic studies in humans with single doses of 0.5 mg and possibly less.

Integrity signals

Registry

Crossref · 10.1016/0378-4347(96)00118-1

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Marfil, F., Pineau, V., Sioufi, A., & Godbillon, J.
Corresponding author
Marfil, F.
Venue
Journal of Chromatography B: Biomedical Sciences and Applications
Publisher
Elsevier BV
Published
1996-08
Volume
683
Issue
2
Pages
251-258
ISSN
0378-4347 (ISSN-L)
OpenAlex
W2060524204
Cited by
51
References
0
Citations by year
2022: 1 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 7
FWCI
0.79
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography B Biomedical Sciences and Applications (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
Keywords
letrozole, aromatase inhibitors, plasma drug quantification, fluorescence detection, pharmacokinetics, bioanalytical method validation
MeSH terms
Letrozole, Aromatase, Calibration, Chromatography, High Pressure Liquid, Circadian Rhythm, Enzyme Inhibitors, Fasting, Humans, Nitriles, Sensitivity and Specificity, Spectrometry, Fluorescence, Triazoles, Reproducibility of Results, Aromatase Inhibitors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review