High-performance liquid chromatography of the aromatase inhibitor, letrozole, and its metabolite in biological fluids with automated liquid-solid extraction and fluorescence detection
Abstract
An analytical method for the determination of letrozole (CGS 20,267) in plasma and of letrozole and its metabolite, CGP 44,645, in urine is described. Automated liquid-solid extraction of compounds from plasma and urine was performed on disposable 100-mg C8 columns using the ASPEC system. The separation was achieved on an ODS Hypersil C18 column using acetonitrile-phosphate buffer, pH 7, as the mobile phase at a flow-rate of 1.5 ml/min. A fluorescence detector was used for the quantitation. The excitation and emission wavelengths were 230 and 295 nm, respectively. The limits of quantitation (LOQ) of letrozole in plasma and in urine were 1.40 nmol/l (0.4 ng/ml) and 2.80 nmol/l, respectively. The respective mean recoveries and coefficient of variation (C.V.) were 96.5% (9.8%) in plasma and 104% (7.7%) in urine. The LOQ of CGP 44645 in urine was 8.54 nmol/l (2 ng/ml). The mean recovery was 108% (6.3%). The compounds were well separated from co-extracted endogenous components and no interferences were observed at the retention times of compounds. The sensitivity of this method for letrozole in plasma should be sufficient for kinetic studies in humans with single doses of 0.5 mg and possibly less.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Solid-phase extraction methods with fluorescence detection for LTZ resulted in longer retention times and time-consuming processing.
“Fluorescence detection has been reported to quantify LTZ in human plasma and urine (Marfil et al. 1996; Zarghi et al. 2007). However, these solid-phase extraction methods resulted in longer retention times and time-consuming processing.”
From A simple, precise, and sensitive HPLC method for quantification of letrozole in rat plasma: development, validation, and preclinical pharmacokinetics (2021) · cites this paper as Marfil et al. 1996
Cited by
Sorted by citations
Pfister, C. U., Martoni, A., Zamagni, C., Lelli, G., De Braud, F., Souppart, C., Duval, M., & Hornberger, U. (2001) · Biopharmaceutics & Drug Disposition · doi:10.1002/bdd.273 · Cited by 101 · see citing works
Acharjya, S., Mallick, P., Panda, P., Kumar, K., & Annapurna, M. (2010) · Journal of Advanced Pharmaceutical Technology & Research · doi:10.4103/0110-5558.72425 · Cited by 46 · see citing works
“On a detailed literature survey, it was found that letrozole could be estimated by spectrophotometry,[3-4] Highperformance liquid chromatography (HPLC),[5-10] the microarray approach,[11] capillary gas chromatographic method with flame ionization detector,[12] and by gas chromatography – mass sprectrometry (GC / MS)[1…”
MethodHegde, A. R., Padya, B. S., Soman, S., & Mutalik, S. (2021) · Journal of Analytical Science and Technology · doi:10.1186/s40543-021-00276-4 · Cited by 17 · see citing works
“Fluorescence detection has been reported to quantify LTZ in human plasma and urine (Marfil et al. 1996; Zarghi et al. 2007).”
Background
- Authors
- Marfil, F., Pineau, V., Sioufi, A., & Godbillon, J.
- Corresponding author
- Marfil, F.
- Venue
- Journal of Chromatography B: Biomedical Sciences and Applications
- Publisher
- Elsevier BV
- Published
- 1996-08
- Volume
- 683
- Issue
- 2
- Pages
- 251-258
- ISSN
- 0378-4347 (ISSN-L)
- OpenAlex
- W2060524204
- Cited by
- 51
- References
- 0
- Citations by year
- 2022: 1 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 3 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 7
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Chromatography B Biomedical Sciences and Applications (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
- Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Keywords
- letrozole, aromatase inhibitors, plasma drug quantification, fluorescence detection, pharmacokinetics, bioanalytical method validation
- MeSH terms
- Letrozole, Aromatase, Calibration, Chromatography, High Pressure Liquid, Circadian Rhythm, Enzyme Inhibitors, Fasting, Humans, Nitriles, Sensitivity and Specificity, Spectrometry, Fluorescence, Triazoles, Reproducibility of Results, Aromatase Inhibitors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review