Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,568

The DOI matches its Crossref record.

Relation of transmitral flow velocity patterns to left ventricular diastolic function: New insights from a combined hemodynamic and Doppler echocardiographic study

Open access
Appleton, Christopher P., Hatle, Liv K., Popp, Richard L.·1988·Journal of the American College of Cardiology

Abstract

In an effort to determine what clinically useful information regarding left ventricular diastolic function can be inferred noninvasively with pulsed wave Doppler echocardiography, mitral flow velocity patterns and measured variables were correlated with hemodynamic findings in 70 patients: 30 with coronary artery disease, 20 with idiopathic congestive cardiomyopathy, 14 with a restrictive myocardial process and 6 without significant cardiac disease. The effect of sudden changes in hemodynamics on the mitral flow velocity pattern was also investigated in a subgroup of patients who had simultaneous recording of mitral flow velocity and left ventricular pressure before and after left ventriculography. Mitral flow velocity recordings from 30 healthy adults served as a reference group. This analysis suggests that 1) the majority of patients with these cardiac disorders demonstrate abnormal mitral flow velocity patterns or variables; 2) markedly different flow velocity patterns can be seen in patients with impaired left ventricular relaxation; 3) the different mitral patterns appear to relate more to myocardial function and hemodynamic status than to the type of disease process present; 4) certain mitral patterns suggest different filling pressures and rates of early diastolic left ventricular filling; 5) an increase in left atrial pressure can "normalize" an abnormal mitral flow velocity pattern and "mask" a left ventricular relaxation abnormality; and 6) the different patterns appear to represent a dynamic continuum with the potential to change from one to another as a result of disease progression, medical therapy or sudden changes in hemodynamics. It is concluded that, despite the indirect method of estimation and certain limitations, mitral flow velocity recordings have clinical potential in assessing left ventricular diastolic function that merits further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/0735-1097(88)90416-0

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 1,568

Metadata

Authors
Appleton, C. P., Hatle, L. K., & Popp, R. L.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
1988-08
Volume
12
Issue
2
Pages
426-440
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2014671408
Cited by
1,568
References
0
FWCI
39.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relation of transmitral flow velocity patterns to left ventricular diastolic function: New insights from a combined hemodynamic and Doppler echocardiographic study. https://app.cochat.ai/papers/10.1016/0735-1097(88)90416-0
The paper
Appleton, C. P., Hatle, L. K., & Popp, R. L. (1988). Relation of transmitral flow velocity patterns to left ventricular diastolic function: New insights from a combined hemodynamic and Doppler echocardiographic study. Journal of the American College of Cardiology. https://doi.org/10.1016/0735-1097(88)90416-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.