Effect of exercise level on the ability of thallium-201 tomographic imaging in detecting coronary artery disease: Analysis of 461 patients
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This study examined the effect of the level of exercise on the ability of thallium-201 imaging with single photon emission computed tomography (SPECT) to detect coronary artery disease. Patients in group 1 (n = 164) achieved adequate exercise end points, defined as positive exercise electrocardiograms or greater than or equal to 85% of maximal predicted heart rate. Patients in group 2 (n = 108) had submaximal exercise. The SPECT thallium-201 images showed perfusion defects in 74%, 88%, and 98%, respectively, of patients with one, two and three vessel coronary artery disease in group 1, compared with 52%, 84% and 79%, respectively, of such patients in group 2 (p less than 0.05). Perfusion defects showed partial or complete redistribution consistent with ischemia in 56%, 80% and 88%, respectively, of patients with one, two and three vessel coronary artery disease in group 1 compared with 35%, 58% and 56%, respectively, of such patients in group 2 (p = 0.08, less than 0.03 and less than 0.001, respectively). Of 58 patients with normal coronary angiograms or less than 50% diameter stenosis, 36 (62%) had normal SPECT images. In a separate group of 131 patients with less than 5% pretest probability of coronary artery disease, the specificity was 93%. The sensitivity of exercise SPECT imaging in group 1 was higher than that of ST segment depression (p less than 0.001). Thus, the level of exercise affects the results of SPECT thallium imaging in the localization and evaluation of the extent of coronary artery disease and the detection of ischemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
White, C. W., Wright, C. B., Doty, D. B., Hiratza, L. F., Eastham, C. L., Harrison, D. G., & Marcus, M. L. (1984) · New England Journal of Medicine · doi:10.1056/nejm198403293101304 · Cited by 1,222
Guidelines for exercise testing
Feild, M. D. J. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80208-x · Cited by 527
Quantification of rotational thallium-201 myocardial tomography.
Garcia, E. V., Train, K. F. V., Maddahi, J., Prigent, F., Friedman, J. D., Areeda, J. S., Waxman, A. D., & Berman, D. S. (1985) · PubMed · Cited by 439
Visual estimates of percent diameter coronary stenosis: “A battered gold standard”
Marcus, M. L., Skorton, D. J., Johnson, M. R., Collins, S. M., Harrison, D. G., & Kerber, R. E. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90226-4 · Cited by 262
Maddahi, J., Garcia, E. V., Berman, D. S., Waxman, A., Swan, H. J., & Forrester, J. (1981) · Circulation · doi:10.1161/01.cir.64.5.924 · Cited by 257
Alternative Referent Standards for Cardiac Normality
Rozanski, A., DIAMOND, G. A., FORRESTER, J. S., Berman, D. S., MORRIS, D., & SWAN, H. J. C. (1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-101-2-164 · Cited by 132
Normal SPECT thallium-201 bull's-eye display: gender differences.
Eisner, R. L., Tamas, M. J., Cloninger, K., Shonkoff, D., Oates, J. A., Gober, A., Dunn, D. W., MALKO, J. A., Churchwell, A. L., & Patterson, R. E. (1988) · PubMed · Cited by 91
Rc, S., Cg, B., Brandenburg, R. O., DeBusk, R. F., Mh, E., Gf, F., Froelicher, V. F., Rj, H., Bd, M., & McHenry, P. L. (1986) · PubMed · Cited by 77
Iskandrian, A. S., & Segal, B. L. (1981) · The American Journal of Cardiology · doi:10.1016/0002-9149(81)90601-9 · Cited by 77
Self-citationColby, J. M., Hakki, A., Iskandrian, A. S., & Mattleman, S. J. (1983) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(83)80372-6 · Cited by 72
Self-citationEsquivel, L., Pollock, S. G., Beller, G., Gibson, R. S., Watson, D. D., & Kaul, S. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)90278-6 · Cited by 56
Kirklin, J. K., McGiffin, D. C., Plumb, V. J., Epstein, A. E., & Kay, G. N. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90493-0 · Cited by 37
Cited by
Gibbons, R. J., Chatterjee, K., Daley, J., Douglas, J. S., Fihn, S. D., Gardin, J. M., Grunwald, M. A., Levy, D., Lytle, B. W., O’Rourke, R. A., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00150-3 · Cited by 633
Underwood, S. R., Anagnostopoulos, C., Cerqueira, M., Ell, P. J., Flint, E. J., Harbinson, M., Kelion, A. D., Al-Mohammad, A., Prvulovich, E. M., Shaw, L. J., et al. (2004) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1344-5 · Cited by 481
Accuracy and limitations of exercise echocardiography in a routine clinical setting
Marwick, T. H., Nemec, J. J., Pashkow, F. J., Stewart, W. J., & Salcedo, E. E. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90054-q · Cited by 383
Iskandrian, A. S., Chae, S. C., Heo, J., Stanberry, C. D., Wasserleben, V., & Cave, V. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90174-y · Cited by 363
Self-citationQuiñones, M. A., Verani, M. S., Haichin, R. M., Mahmarian, J. J., Suarez, J., & Zoghbi, W. A. (1992) · Circulation · doi:10.1161/01.cir.85.3.1026 · Cited by 316
Metadata
- Authors
- Iskandrian, A. S., Heo, J., Kong, B., & Lyons, E.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 1989-11
- Volume
- 14
- Issue
- 6
- Pages
- 1477-1486
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W1970189439
- Cited by
- 324
- References
- 12
- FWCI
- 21.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.